Reports until 17:47, Thursday 28 October 2010
H2 General
corey.gray@LIGO.ORG - posted 17:47, Thursday 28 October 2010 (273)
H2's ETMy (& a few other things) Removed
(Corey, Doug, Jodi, Kyle, Mitchell, Travis)

Once BSC6 was vented and the door was removed (around 2:30-ish?), the crew started with removal of ETMy.  This involved:
o Much staging
o Taking contamination sample of chamber
o Setting ETMy on earthquake stops (with teflon on tips of stops)
o Installing LOS Installation fixturing
o Removing ETMy
o Removing part of the ETMy telescope

Tomorrow, we will remove the rest of the Telescope and the hockey puck weights.
Images attached to this report
LHO FMCS
kyle.ryan@LIGO.ORG - posted 17:19, Thursday 28 October 2010 (272)
Vented Y-mid
Kyle-vented Y-mid 

Kyle, Travis-Removed BSC6 south door.
X1 SEI
jeffrey.garcia@LIGO.ORG - posted 16:14, Thursday 28 October 2010 (271)
Ops Day Summary
Today's Activities:

Mid-Y activities - Kyle, Jodie, and others - venting of BSC 6 at Mid-Y.

Michael R. making PSL measurements in LVEA
~14:45 local – contractor on-site for PSL flooring quote

Corey and Betsy using crane near HAM1 and H1 PSL

Filiberto, Richard, and contractors dismantling H2 racks

Ski, Mike L. in LVEA  - taking apart the old H2 PSL table enclosure

Removal of the test mass begins at Mid-Y BSC 6 (Doug Cook, others)

----

By 16:15 local, work continues at the Mid-Y BSC 6 for the removal of the test mass.

H2 DAQ
david.barker@LIGO.ORG - posted 10:21, Thursday 28 October 2010 (269)
DAQ reconfigure and restart
As was pointed out, removing the ini files from the DAQ means that
most H1 channels were removed and S6 data could not be trended.
So I put back in the H1 ini files, but set their acquire flag
to zero. All H1 chans should be viewable by dtt and dataviewer,
and the archived frames should be accessible.
LHO FMCS
kyle.ryan@LIGO.ORG - posted 17:59, Wednesday 27 October 2010 (268)
Vertex vent activities and Y-mid purge air
Ski, Kyle, Hugh - Craned forklift over XBM.  

Kyle, Ski, Travis, Andres, Betsy, Cheryl, Patrick, Hugh - Removed HAM2 East Door then rehung following Cheryl's in-chamber work.  Removed HAM3 East Door and rehung following Cheryl's in-chamber work.  

Kyle - Started Y-mid purge air compressors.  
X1 SEI
jeffrey.garcia@LIGO.ORG - posted 17:52, Wednesday 27 October 2010 - last comment - 14:40, Thursday 28 October 2010(267)
SEI test stand medm changes
The LHO X1 SEI test stand had some unusual parameters this morning. I was not able to isolate the table with older Robust Control filters, even with just putting a 0.1 gain on the controller.  I noticed the un-filtered geophone channels nearly saturating.  To be safe, I rebooted the frontend code, but the problem remained. 

I then checked the damping loops - they were engaged.  However, the gains on the outputs were set to 1.  I thought this was the nominal value until I tried to un-damp, then re-damp the table - no success.  The actuators saturated immediately, tripping the watchdog.  So, I then tried a negative gain and ramping from -0.1 to -1 - success.  I had forgotten the gains on the Damping loop outputs were negative -1, while all other loops have positive gains.

After this, control loops were still unstable, tripping the Displacement sensors.  I noticed the Blend filters were off, and then after enabling, the robust control filters isolated the table.

I am not aware as to how (or why) the values were changed in the medm, but the Damping outputs have been at +1 since Oct 21. The watchdog was on the brink of tripping with the +1 gain.  They seem stable now with the negative gain - geophone channels are at safe levels and isolation is on.


Comments related to this report
corey.gray@LIGO.ORG - 14:40, Thursday 28 October 2010 (270)
Perhaps this is a reason for getting a conlog system for the SEI Test Stand.
H2 INS
patrick.thomas@LIGO.ORG - posted 17:12, Wednesday 27 October 2010 - last comment - 15:55, Tuesday 02 November 2010(266)
trying to run motor controllers, weather stations, dust monitors, video & projector controls from svn checkout
Did not succeed. For some reason my compiles are deleting the object files and then complaining that they're gone. I don't know what is going on, so I copied the old code back for now. I restarted everything except the motor controllers, since we are not using them for awhile.
Comments related to this report
patrick.thomas@LIGO.ORG - 15:55, Tuesday 02 November 2010 (284)
Seems that deleting my local .subversion directory and rechecking out the repository might have fixed it. Odd, might have something to do with the restore from the earlier hanford2 crash?
H2 INS
cheryl.vorvick@LIGO.ORG - posted 16:18, Wednesday 27 October 2010 (265)
Optics in HAM2 and HAM3 locked Down:
MMT2, MC2, and RM are on earthquake stops.  I used both front and back stops for the small optics, and the South side stops on the RM (opposite the elliptical baffle).

Everyone involved: Cheryl, Betsy, Patrick, Kyle, Ski, Travis, Andres
H2 INS
michael.rodruck@LIGO.ORG - posted 16:16, Wednesday 27 October 2010 (264)
Ops Day Summary
Big thing today was removal of HAM 2 and 3 doors, EQ stops screwed in on MMT2, MC2, and RM. Doors are back on.
Dave removed H2 channels from the DAQ and several H1 channels as well. 
Patrick is working on several IOCs, which are currently disconnected
TCS enclosures were disconnected from the laser safety network, Dani is aware of this
Dani removing optics from ISCT10, finished today
Cleaning at MY and EY
Apollo at EX
More cable pulling from Filiberto/Cyrus
H2 INS
david.barker@LIGO.ORG - posted 12:31, Wednesday 27 October 2010 (263)
alog was down for about 20 mins
alog had a possible authentication error over the past
20mins. I restarted the httpd process and it seems
to be ok now, but not sure if the restart really
fixed it.
H2 INS
david.barker@LIGO.ORG - posted 12:03, Wednesday 27 October 2010 (262)
Removing channels from the iligo frames
As part of the H2 deinstall and the H1 mothballing, I am removing channels from the iligo
frames when they contain no useful information. We are doing this to reduce the frame size,
which saves on LDAS tape costs and increases our local data lookback period.

I removed disconnected chans plus all H2 chans from H0EDCU.ini

I edited the fb0c master file and removed many inifiles.

svn versions: 174 = end of S6
177 = today's version
LHO FMCS
john.worden@LIGO.ORG - posted 07:38, Wednesday 27 October 2010 (260)
LVEA HVAC Heaters
I have turned off two stages of heat in the LVEA. With lights and cleanrooms operating we should be able to get by without these.
X1 SEI
jeffrey.garcia@LIGO.ORG - posted 19:52, Tuesday 26 October 2010 (259)
SEI SVN checkout location updated
The seismic SVN repository has been moved to Kerberos access control, with the new location being: https://svn.ligo.caltech.edu/svn/seismic.  (The previous site was https://svn-private.ligo.caltech.edu/repositories/seismic)

Instead of wiping away the old directory and checking out the entire new one, I simply switched the site the SVN uses to update its local copy.  I switched the site for the LHO CDS "controls" account (in the control room) and the X1 SEI Workstation copies.

On the X1 SEI workstation, the repository local path is still the same:
'/opt/svncommon/seisvn/seismic/HAM-ISI/'

And in the Control Room, the "controls" user copy is still located at:
'/hanford2/users/controls/isi_local_files/SVN/seismic/HAM-ISI/'

New user names and passwords are the LIGO.ORG ones.  

On the workstation, here's the command I entered to switch the checkout site:

>> svn switch --relocate https://svn-private.ligo.caltech.edu/repositories/seismic/HAM-ISI/ https://svn.ligo.caltech.edu/svn/seismic/HAM-ISI/ --username jeffrey.garcia@LIGO.ORG

*entered in the '~/seismic/HAM-ISI/' directory.
 
LHO FMCS
kyle.ryan@LIGO.ORG - posted 19:20, Tuesday 26 October 2010 - last comment - 07:41, Wednesday 27 October 2010(258)
BSC1, HAM2, HAM3 doors
Kyle, Ski - removed BSC1 south door.  Rehung a few hours later.  

Kyle - Removed all but (4) door bolts from HAM2 and HAM3 East doors (Note-dropped large wrench from top of HAM3 and it hit cross beam)
Comments related to this report
john.worden@LIGO.ORG - 07:41, Wednesday 27 October 2010 (261)
Note to Operators regarding door removals: Whenever a BSC or HAM chamber is prepped for door removal you will see annulus ion pump alarms. These may remain in alarm for the duration of the vent. Ask Kyle or John for more info if needed.
H2 INS
keita.kawabe@LIGO.ORG - posted 18:06, Tuesday 26 October 2010 (257)
ISC table deinstall continues. ISCT10 access system "offline".
We moved to ISCT10.

One particularly dirty lens that was just sitting on top of a small aluminum table  OUTSIDE of ISCT10 enclosure along with viewers and such (not used for anything, but who'd put a lens OUTSIDE of the table enclosure?) was thrown away. Finger print and scratches all over.

At some stage all the lights of the card reader went out. This was found by me later when I tried to swipe out of ISCT10, I called the control room, and Jonathan Berliner found that ISCT10 was "offline", whatever that means. 

LSO (Dani) reset my card so I was able to continue working, but ISCT10 is still "offline". Did somebody cut off the power to the access system for this table?
H2 General
jonathan.berliner@LIGO.ORG - posted 17:42, Tuesday 26 October 2010 (256)
Last Ops Log
Pacific Daylight Time:
1227 - Done at BSC1,2,3
1234 - Cheryl returns to BSC2 with Patrick for ~15 minutes of checks 
1248 - EY cryopump alarms
1254 - Illuminator lights turned off via MEDM, power supply in LVEA left on
1317 - Dale out to H1 PSL to position camera for LaserFest recording
1330 - Gerardo out to LVEA to talk to Filiberto
1342 - Door Forced at EX (card APB, i addressed it) and at LVEA
1345 - DEA reports ISCT7 done
1347 - Gerardo out
1352 - Dale reports loud noise in LVEA due to microphone feedback from speaker.  He is also concerned for people who may complain about RF interference with other people's work.
1436 - Jodi and Kyle moving engine hoist from EX to MY
1445 - Betsy goes out to HAM1-3 to prepare cleanrooms for door removal
1511 - Corey opens Large Equipment Access Door.
1520 - Patrick out to LVEA to find Cheryl
1528 - Michael Rodruck back to LVEA for more measurements.
1609 - Jodi ook Optics Cart, straddle lift, and CP Stat foil dispenser from LVEA to MY, and is now back
1610 - Apollo guys finish replacing beam tube curtains...will commence crane-cleaning at 7:30am.

Addenda:
- I tried following up with as many Door Forced alarms as possible, but was successful less than 10% of the time in reaching the culprits by phone.  They will not be recorded in my future logs.  Currently, WAPAC reads Off-line for LVEA, but people report that it works.
- Ignore all ion pump alarms.

X1 SUS
jeffrey.bartlett@LIGO.ORG - posted 16:36, Tuesday 26 October 2010 (255)
Quad 2 OSEM Testing
Mark Barton and I are continuing testing of Quad 2 and developing the testing procedures. Tests look good for main chain. However, there are some issues with the reaction chain, which we will continue working on tomorrow. 
H2 INS
filiberto.clara@LIGO.ORG - posted 15:52, Tuesday 26 October 2010 (254)
Uninstall of H2 Electronics continues
Removal of H2 Electronics from LVEA continues.
Images attached to this report
Displaying reports 88021-88040 of 88273.Go to page Start 4398 4399 4400 4401 4402 4403 4404 4405 4406 End