jonathan.berliner@LIGO.ORG - posted 14:41, Tuesday 26 October 2010 - last comment - 14:45, Tuesday 26 October 2010(251)
Option to show 20,50,100, etc. Entries Per Page
Just saying.
Comments related to this report
jonathan.berliner@LIGO.ORG - 14:44, Tuesday 26 October 2010 (252)
and to make the details field optional.
jonathan.berliner@LIGO.ORG - 14:45, Tuesday 26 October 2010 (253)
[no details]
H2 INS
cheryl.vorvick@LIGO.ORG - posted 14:15, Tuesday 26 October 2010 (250)
H1 BSC1,2,3 Optics Lockdown
Locked down ITMX, ITMY, and BS.  ITMX and ITMY have eLigo glass earthquake (EQ) stops - BS has iLigo viton EQ stops.

On ITMs I used the four EQ stops on the face of the optic to push it onto the back EQ stops, securing it without having to remove the elliptical baffle, or working near OSEMs.  On the BS, I used EQ stops on both sides to secure the optic.

Both ITMs:
All EQ stops showed some evidence of martial removal where the EQ stops contact the optic chamfer.

ITMY: 
When looking at the face of the optic, the Lower Right EQ stop seemed to be very close to the optic.  It's very possible that the venting of the chamber shifted the optic position, so it's unclear if this was the situation under vacuum.

ITMX:
When working with Patrick I turned one EQ stop (LR when looking at the otic face) too far and slightly ground the glass, which could be heard, effectively showing him what not to do.

Contamination:
Evidence of particulate in all BSCs, and HAM3.
H2 INS
dani.atkinson@LIGO.ORG - posted 13:56, Tuesday 26 October 2010 (249)
ISCT7 Cleared
Dani and Keita

ISCT7 has been cleared of all optics and other components, excepting the large PDs (which Richard will take), the accelerometers (needs plugs pulled), and a rotation stage (needs plugs pulled).
H2 General
jonathan.berliner@LIGO.ORG - posted 12:04, Tuesday 26 October 2010 (248)
Oct 26 2010 Ops Mid-Shift Log
Times in Pacific Daylight Time:
0908 - Input violation at LVEA roll-up door
0912 - Diamond Freight for Betsy Bland
0916 - Door Forced at MY
0922 - UniFirst
0928 - Dave Barker begins pulling H1 channels
0931 - Jodi to HAM6 to retrieve curtain
0942 - Sprague
0943 - Mike Landry out for 5 minutes to LVEA with Jodi
0956 - Eric takes truck over X-arm bridge to other side of LVEA to HAM12 side, cleans up vacuum equipment
0958 - 4k SUS MC watchdogs start beeping off
1004 - Cover Open West Emergency Exit Doors
1011 - HVE LY pump alarm
1016 - Gerardo unloads stuff at MY
1021 - Sprague returns
1022 - American Crossroads calls Control Room (again)...we should get off of their list.
1024 - Jodi will open roll-up door by high bay
1038 - Corey and Eric A. cleaning up by HAM12
1044 - Betsy goes to BSC1
1054 - Door Forced X-End
1110 - Rick out to LVEA for LaserFest rehearsal
1112 - Door Forced X-End
1110 - Illuminator lights turned on in BSC1,2,3.  Turn on power supply in VEA and then use MEDM H0VIDEO_ILLUM.
1114 - Cover Open West Emergency End
1128 - Sprague is back
1137 - Gerardo is official runner for BSC1
1140 - Praxair delivery
1145 - Eric done at HAM12, Corey still taping up roughed up concrete.
1159 - Rodruck out to LVEA for PSL work
1150 - Corey declares HAM12 done
1201 - KingAir here to work on RO
H2 General
jonathan.berliner@LIGO.ORG - posted 09:25, Tuesday 26 October 2010 (247)
Many Open Work Permits
(Reminder for myself and relevant persons)

#2582 - De-install H2 EY LOS (Doug Cook)
#2584 - LaserFest at H1PSL (Dale Ingram)
#2583 - ISCT7 Decommissioning (Keita Kawabe)
#2581 - Close GV1,2 Vent Vertex (Kyle Ryan)
#2580 - Close GV10,11 Crane Scissor lift over VE to North side of LVEA (Kyle, Ski)
#2577 - Turn on LVEA clean rooms (Cheryl Vorvick)
#2576 - Soft-close GV5,7 (John)
#2579 - Remove H2 EY Transmission Monitor (Gerardo Moreno)
#2573 - Drill Holes for HAM12 (Corey Gray)
#2574 - De-install H2 TCS (Cheryl)
#2571 - Remove H2 electronics (Richard McCarthy)
#1793 - Install temp. patch finders at MX (McCarthy)
#2563 - Characterize optical losses in IMC (Rick Savage)
#2566 - Remove all H2 channels from frame (Dave Barker)
#2553 - Remove VME cards from H2 (McCarthy)
#2530 - Installl infrasound mic at EX (Robert Schofield)
#2524 - PSL table leg experiments (Rick)
#2500 - PSL table leg experiments (Rick)
#2304 - Install fb1c (Dave)

When complete, please sign your permit out.
H2 General
corey.gray@LIGO.ORG - posted 21:28, Monday 25 October 2010 (246)
HAM12 SEI Pier Anchor Holes & Floor Roughing Complete
(Eric A., Corey G.)
After the BSC1 cleanroom was engaged we were given the go-ahead to finish the dirty job of roughing the concrete for the HAM12 Piers.  This work was completed around 5:30 (well, almost complete:  I cleaned up most of our mess, but there are quite a few items we need to put away---will leave this for tomorrow).  The floor around HAM12 was sweeped and then wet-mopped.  We also utilized a HEPA fan to help keep our mess to a minimum, and this worked out great (thanks Rick & Eric!).  I will close out our work permit tomorrow when our mess is cleaned up.
H2 INS
patrick.thomas@LIGO.ORG - posted 18:01, Monday 25 October 2010 (242)
Ops Day Summary
Richard and Filiberto started pulling the H2 electronics from the LVEA.

H0:FMC-MX_CY_H2O_PUMPSTAT is failed. See Ski's elog
Sno Valley came to look at the part numbers for the pump.

Keita and Dani started pulling optics from ISCT7.

Rick rigged up a HEPA filter near HAM12 to pull in the dust from the scouring.
Corey and Eric finished the prepping work for the HAM12 pier anchor bolts.

Kyle closed GV1, GV2, GV10 & GV11, started venting the vertex and HAM6.

Gerardo removed the H2-ETMY transmission monitor.

Jodi and Ski prepped for the BSC1 vent and worked on the clean room at mid Y.

Apollo cleaned at Y end.

Cyrus turned tidal off.

John Zweizig started migrating the DMT viewers to the advanced ligo configuration.

Dave removed the disconnect channels from the EDCU.

Reboldt worked at the LSB.
H2 INS
keita.kawabe@LIGO.ORG - posted 17:58, Monday 25 October 2010 (245)
ISC deinstall starts
Started pulling optics etc. from ISC 7.

General purpose mounts, beam dumps etc. are restocked in the optics lab cabinets. 

Most of labeled optics are put in boxes and stored in ISC cabinets, some are returned to the optics lab.

The work will continue several days more.
LHO FMCS
kyle.ryan@LIGO.ORG - posted 17:46, Monday 25 October 2010 (244)
Vertex vent activities and Y-mid gate valves
Closed GV10 and GV11 (Ski et al. craning scissor lift over VE).  Note GV11 "clanked" atypically when gate cammed closed.  



Started CS purge air compressor*Closed GV1 and GV2*Started Vertex, XBM and YBM QDP80s and Main turbo pumps*Vented Vertex and HAM6 volumes simultaneously (note: new requirement to maintain <0.5 atm pressure difference across HAM6 septum as the result of design flaw awarness-see Mike Z., Dennis C., John W., Albert L.)*Isolated BSC1 annulus ion pump*removed all but (4) door bolts from BSC1 South door
H2 DAQ
gregory.mendell@LIGO.ORG - posted 17:39, Monday 25 October 2010 (243)
DCS (LDAS) transition to A6 (After S6) archiving of DAQ (CDS) data
DCS (LDAS) transitioned to A6 (meaning "After S6") on Oct. 20, 2010, shortly after 8 am local time. During this time period all raw (L0) data at LHO and LLO is being copied to the site LDAS archives, and also is being transferred to the CIT LDAS archive, whenever this data is available from any of the DAQ (CDS) framewriters. The same holds for second-trend and minute-trend data. We continue to rsync any new DMT data, whenever it is available, but no LDAS RDS data is being generated during this time period.

Note that the raw (L0) data will soon be pared down to mostly PEM data, and there will be no interferometer data until squeezing data and aLIGO test data begins to be written to the raw frames. 

Thus, if you are looking for data "After S6" outside of the control room, ask about A6 data.
X1 SUS
jeffrey.bartlett@LIGO.ORG - posted 16:28, Monday 25 October 2010 (241)
Top Mass Magnets and Sgns
Reset all Top Mass flag magnets on Quad-2 to conform to Derek’s document E1000617. Set the Gains in MEDM to conform to Mark’s document E1000494. Ran Actuator Sign Test and all responses were positive. 

Main Chain 
FACE1	N	-1
FACE2	S	 1
FACE3	N	-1
LEFT	S	 1
RIGHT	N	-1
SIDE	N	-1

Reaction Chain      
FACE1	N	 ?  No apparent actuation
FACE2	N	-1
FACE3	S	 1
LEFT	N	-1
RIGHT	S	 1
SIDE	N	-1
H2 INS
gerardo.moreno@LIGO.ORG - posted 14:33, Monday 25 October 2010 (240)
H2-ETMY Transmission Monitor Removed
Removed transmission monitor and components, including green pier.
Components are stored inside the VEA, they will be removed in the near future.

Output viewport is covered with a safety viewport cover.

Cables were removed last week, see here.
X1 SUS
betsy.weaver@LIGO.ORG - posted 09:44, Monday 25 October 2010 (239)
Q2 Magnet polarities and servo controls
M0:
FACE1   S
FACE2   N
FACE3   S
LEFT    N
RIGHT   S
SIDE    N

R0:
FACE1   S
FACE2   S
FACE3   N
LEFT    S
RIGHT   N
SIDE    N

Which gives the following signs on the OUTPUT gains.

M0:
FACE1   1
FACE2  -1
FACE3   1
LEFT   -1
RIGHT   1
SIDE   -1

R0:
FACE1   ? Having problems
FACE2   1
FACE3  -1
LEFT    1
RIGHT  -1
SIDE   -1

The polarities appear to be 180 deg out of phase from Derek's poster cheat sheet E1000617.
Jeff is going to go switch all magnets and then reset the servo gain signs.  Hopefully this will then match the poster.
LHO FMCS
kyle.ryan@LIGO.ORG - posted 16:52, Friday 22 October 2010 (238)
Y-end instrument air alarm
Had transient low value for the instrument air pressure at the Y-end station this morning.  No recent history or trend -> probably due to users activity.
H2 General
patrick.thomas@LIGO.ORG - posted 16:24, Friday 22 October 2010 (237)
Ops Day Summary
The instrument air pressure briefly alarmed, Kyle has been notified:
22-Oct-2010 10:17:34 : HVE-EY:INSTAIR_PT499         LOW          MAJOR            59

Apollo finished cleaning in the LVEA

The crane inspections in the LVEA are completed

The crane training class was held this morning

Cheryl and Aidan continued TCS decommissioning
Cheryl turned the clean rooms on in the LVEA

Corey and Eric continued drilling holes at HAM 12

Gerardo, Cyrus and Jodi worked on the clean rooms at mid Y

Reboldt came to work at end Y

The Genie lift was moved to end Y, Apollo will probably begin cleaning there next week
H2 INS
gerardo.moreno@LIGO.ORG - posted 15:57, Friday 22 October 2010 (236)
Optical Lever Power Supplies
Finished removal of optical lever power supplies, removed the power supply for ETMX and ETMY.
Power supplies are stored on the racks of receiving/storage area of the LSB.
H2 General
corey.gray@LIGO.ORG - posted 13:16, Friday 22 October 2010 (233)
HAM12 HAM Pier Anchor Holes Drilled
(Eric A., Corey G.)
All the holes have been drilled (15 today.  It took one $200 Hilti drill bit to get through about 14 holes--that steel rebar is a pain!).

Eric will clean out the holes, check their depths, and cover them with tape.  The vinyl-ish flooring has been removed.  The final thing we would like to do is rough the concrete for the grouting--will try to do this Monday, time permitting.
X1 SUS
jeffrey.bartlett@LIGO.ORG - posted 12:29, Friday 22 October 2010 - last comment - 14:05, Friday 22 October 2010(232)
Glitch on MO Rt Channel

  Still have a glitch in the Main Chain right channel in satellite box 3200715. We have eliminated cables and OSEM as the problem source. Swapped SB 3200715 and SB 320078 and problem stayed on MO Rt. Moved cables back to original position.
 
  We swapped cables on the AA channel and the AI channel. Glitch moved from MO Rt to MO F1; possible problem in the AA or AI chassis. Filiberto is going to do some more testing this afternoon to determine which chassis is at fault.      
Comments related to this report
filiberto.clara@LIGO.ORG - 14:05, Friday 22 October 2010 (234)
Found bad 25 pin D-sub cable (CAB_TSI_SUS_13). Replaced with new cable and MO Right signal does not show the reported glitching from earlier. 
H2 General
cheryl.vorvick@LIGO.ORG - posted 11:30, Friday 22 October 2010 - last comment - 15:43, Friday 22 October 2010(231)
Clean Rooms Started
I've started 3 clean rooms in the LVEA to counteract the dust from cleaning, and get the area ready for vents next week.  HAM3, HAM8, and HAM6 clean rooms are ON.  The clean room over HAM1 needs to have the large switch at the top of the clean room moved to the ON position, before it can be started.  
Comments related to this report
cheryl.vorvick@LIGO.ORG - 15:43, Friday 22 October 2010 (235)
Clean room over HAM1 is now ON.
Displaying reports 88041-88060 of 88272.Go to page Start 4399 4400 4401 4402 4403 4404 4405 4406 4407 End