Displaying reports 88521-88540 of 88614.Go to page Start 4423 4424 4425 4426 4427 4428 4429 4430 End
Reports until 12:22, Wednesday 28 July 2010
H2 General
corey.gray@LIGO.ORG - posted 12:22, Wednesday 28 July 2010 - last comment - 14:14, Wednesday 28 July 2010(103)
New HAM-ISI Transformation Matrices Loaded On Test Stand
Now that we've completed testing on HAM-ISI  Assy #1, we wanted to update our transformation matrices to the more accepted canon (Jeff K. made a new matlab script to generate these matrices which include Celine's work that include the L4Cs among other things).  Jeff G. loaded these briefly a couple of weeks ago, but we reverted to older scripts since we were still in the midst of Unit#1 testing; see his elog for the specifics on the files used & an overall explanation.

Attached are the BEFORE/AFTER values for these matrices.  Now, the new script matrix yields values to 12 sig figs, but EPICS rounds these values to 5 sig figs when they are loaded into our actual/medm matrices.

Noticeably Different CONT2ACT Matrix
The DISP2CEN & GEO2CEN matrices look fairly identical before and after this update.  The noticeable change is with the CONT2ACT matrix.  For this matrix, we have values at different locations and also sign changes.  During the Assy #2 testing, we'll need to confirm that our sign convention is obeyed due to this matrix change.


Non-image files attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 14:14, Wednesday 28 July 2010 (105)
CONT2ACT Matrix Looks FINE!
Looks like a case of Operator Error here--The matrix I loaded CONT2ACT with was actually for the L4C2CEN matrix!  I've rerun the script and acquired/loaded the correct CONT2ACT matrix.  Now CONT2ACT looks closer to what it was before.

So, this is the mistake I ran previously:
>> [GEO2CEN,DISP2CEN,CONT2ACT] = make_HAMX1_projections_100709

It should be:
>> [GEO2CEN,DISP2CEN,L4C2CEN,CONT2ACT] = make_HAMX1_projections_100709

I'm attaching an updated/correct BEFORE/AFTER document.
Non-image files attached to this comment
H2 General
corey.gray@LIGO.ORG - posted 15:48, Monday 26 July 2010 (102)
Cleaning Up Front End Scripts Folder
After a Rolf-model-change a while ago, we ended up making new Front End scripts (i.e. our start & kill scripts).

Our scripts are located at:

/opt/rtcds/geo/g1/scripts

I've made an archive folder in here, and I've put our old start & kill scripts in this archive folder.  So now we have only the "real" ones in this main folder:

* killg1isiham
* killg1x01
* startg1isiham
* startg1x01
X1 SUS
betsy.weaver@LIGO.ORG - posted 14:01, Monday 26 July 2010 - last comment - 13:19, Wednesday 28 July 2010(101)
Q1 EE status - more data problems
It seems that I still cannot get playback data.  I have restarted dv, but the request never opens a plot, _IN1 nor _DAQ channels.  As well, the realtime data for either species looks like it is repeating.  

Also, how do I launch Foton??
Comments related to this report
betsy.weaver@LIGO.ORG - 13:19, Wednesday 28 July 2010 (104)
from xterm terminal in the cleanroom:
ssh -X controls@bscteststand

type foton at the prompt.
X1 SEI
hugh.radkins@LIGO.ORG - posted 16:05, Friday 23 July 2010 (100)
LHO HAM ISI Assembly #1 Testing Completed, Locked and disconnected
With the completion of Assembly #1 testing, the ISI is locked.  Actuator and GS13 Cabling is now disconnected.
X1 SUS
david.barker@LIGO.ORG - posted 12:57, Friday 23 July 2010 (99)
Quad Test Stand DAQ frame channel list
For completeness, here is the list of channels currently
being acquired by the qts (all at 2048Hz).

[L1:QTS-Q1_M0_FACE1_IN1_DAQ]
[L1:QTS-Q1_M0_FACE2_IN1_DAQ]
[L1:QTS-Q1_M0_FACE3_IN1_DAQ]
[L1:QTS-Q1_M0_LEFT_IN1_DAQ]
[L1:QTS-Q1_M0_RIGHT_IN1_DAQ]
[L1:QTS-Q1_M0_SIDE_IN1_DAQ]
[L1:QTS-Q1_M0_X_EXC_DAQ]
[L1:QTS-Q1_PEN_LLSEN_IN1_DAQ]
[L1:QTS-Q1_PEN_LRSEN_IN1_DAQ]
[L1:QTS-Q1_PEN_POS_EXC_DAQ]
[L1:QTS-Q1_PEN_ULOUT_EXC_DAQ]
[L1:QTS-Q1_PEN_ULSEN_IN1_DAQ]
[L1:QTS-Q1_PEN_URSEN_IN1_DAQ]
[L1:QTS-Q1_R0_FACE1_IN1_DAQ]
[L1:QTS-Q1_R0_FACE2_IN1_DAQ]
[L1:QTS-Q1_R0_FACE3_IN1_DAQ]
[L1:QTS-Q1_R0_LEFT_IN1_DAQ]
[L1:QTS-Q1_R0_RIGHT_IN1_DAQ]
[L1:QTS-Q1_R0_SIDE_IN1_DAQ]
[L1:QTS-Q1_R0_X_EXC_DAQ]
[L1:QTS-Q1_UI_LLSEN_IN1_DAQ]
[L1:QTS-Q1_UI_LRSEN_IN1_DAQ]
[L1:QTS-Q1_UI_POS_EXC_DAQ]
[L1:QTS-Q1_UI_ULSEN_IN1_DAQ]
[L1:QTS-Q1_UI_URSEN_IN1_DAQ]

Giving a 16 second full frame file size of 3.2MB.
X1 SUS
david.barker@LIGO.ORG - posted 12:55, Friday 23 July 2010 (98)
State of the QTS DAQ system
Betsy reported two problems with the QTS DAQ this morning, getting past
data and getting real time data using DTT.

The DTT issue was due to the system time being 7 seconds off.
After correcting the system time, I had to restart the DAQ
for DTT to get realtime data. We tested it with DAQ channels
and testpoint channels. I have corrected the root crobtab which
should keep the system clock synchronized to the LHO NTP server.

The trending problem was due to the DAQ not writing trend files
since 19 Apr 2009. However full frames are being written, with 
a look back of 8 days. 

I noticed that only 25 channels are in the frame, all at
2048Hz acquisition rate. Betsy suggested we get together
with Mark next week to see if more channels need to be added
to the frame, and perhaps save some at the 16384Hz native rate.

I also found that the QTS daq system is very old, with frame file
layout as per S5 standards. Could we upgrade this system to aLIGO
standards?
X1 SEI
corey.gray@LIGO.ORG - posted 10:41, Friday 23 July 2010 (97)
More Capacitive Position Sensor (CPS) Spectra For Unit#1: Table LOCKED!
After switching to the new "actual flange BNC feed-thrus", power spectra were run for the CPS's with the table un-locked.  Attached are spectra taken when the table was LOCKED (w/ both mini-racks on & with only one on---as we've done for the previous measurements).

Data is saved at:
/opt/svncommon/seisvn/seismic/HAM-ISI/X1/Data/unit_1/dtt/20100722_all_disp_locked_spectra.xml
Non-image files attached to this report
X1 SEI
corey.gray@LIGO.ORG - posted 10:30, Friday 23 July 2010 (92)
GS13 Spectra From Table Tilt Tests
A few weeks ago, we discovered we had a FAILED Horizontal GS13.  From our quick tests, it seemed as though we had a stuck mass inside the GS13---we were able to free the mass when we tilted the Table.

For an exercise in checking the effects of a tilted table on our remaining functioning GS13s, we carried out some table tilt measurements on the table and looked at spectra from our GS13s (namely the Horizontal ones).

We tilted the table by placing weights on the table in various locations.  We used various types of Adjustment Masses D071200.  Here are masses for the types of weights we used to tilt the table:

Type 1:  0.5 kg
Type 2:  1.0 kg
Type 3:  2.1 kg

As for the tilts, we did a few.  Referencing this coordinate drawing(sorry, for some reason, aLOG wouldn't let me upload this picture), we tilted the table along several axis:

RY:  +RY tilt would have weights placed over the V1 GS13 (-RY had weights on side opposite of V1 Act).  The RY tilts would tilt the H3 GS13 up and down along its axis (which is parallel to X

RX:  +RX tilt would have masses placed over H3 GS13 (-RX would have masses placed on side opposite H3 GS13).  This measurement doesn't really line up with a clean tilt for any of the horizontal GS13's; they are all at angles with respect to RX tilts

"H1":  Here we wanted to perform a tilt for the H1 GS13 (similar to what the RY tilt did 
for the H3 GS13).  A "-H1" tilt had masses placed over the V2 GS13 ("+H1" tilt had masses on spot opposite to V2 GS13.

"H2":  Here we wanted to perform a tilt for the H2 GS13 (similar to what the RY tilt did for the H3 GS13).  A "-H2" tilt had masses placed over the V3 GS13 ("+H2" tilt had masses on spot opposite to V3 GS13.

On this coordinate drawing referenced above,  +Y & +X are the same as H1's (i.e. +Y points toward Rattlesnake Mountain).

Overall, in the measurements we start out with an unlocked & balanced table with it's respective spectra.  Small amount of masses are added (they are posted in each plots title).  The system is ok with a little tilt, but once you get to a certain tilt the spectra changes noticeably (i.e. the primary resonances around 1-2Hz get knocked down & the high frequency behavior changes).

The data for these measurements are saved at:
/opt/svncommon/seisvn/seismic/HAM-ISI/X1/Data/unit_1/dtt
With file names:
20100713_+RXtilt_geo_spectra.xml
20100713_-RXtilt_geo_spectra.xml
20100713_+RYtilt_geo_spectra.xml
20100713_-RYtilt_geo_spectra.xml
20100713_+H1tilt_geo_spectra.xml
20100713_-H1tilt_geo_spectra.xml
20100713_+H2tilt_geo_spectra.xml
20100713_-H2tilt_geo_spectra.xml
Non-image files attached to this report
X1 SEI
jeffrey.garcia@LIGO.ORG - posted 07:38, Friday 23 July 2010 (96)
Too many Dataviewer message queues
I had to clear the message queues for the TestStand this morning due to too many current message queues. The script to do so is 'rmq' in the scripts directory: '/opt/apps/scripts/'
X1 SUS
betsy.weaver@LIGO.ORG - posted 10:54, Thursday 22 July 2010 (95)
QUAD EE Test Stand controls
A quick check on DTT - I loaded a channel in and hit start with default DTT settings loaded (channel was L1:QTS-Q1_MO_FACE1_IN1).  After a few seconds of thinking it gave a "Test timed-out" error at the bottom.  Richard hinted at a timing problem...?

Also - how can I load the "editable" medm?  And, we are ready to calibrate channels.  Instructions on where to do this would be appreciated.

BTW - All 12 Top Mass BOSEMs have been zeroed and are at 50% OLV.  So signals and controls on L1:QTS-Q1_MO and Q1_RO channels are live. 
H2 General
fabrice.matichard@LIGO.ORG - posted 17:52, Wednesday 21 July 2010 - last comment - 09:52, Thursday 22 July 2010(93)
HAM-ISI Unit 1, Lower zero moment point
The attached document shows the transfer functions used to compute the LZMP.

The number we have are good: 0.24 mm and 0.30 mm in the X and Y directions respectively.

However, we need a better coherence on the cross couplings in order to confirm these numbers. We are doing another measurement with much more averages (a 6 hours drive in each X direction).
Non-image files attached to this report
Comments related to this report
fabrice.matichard@LIGO.ORG - 09:52, Thursday 22 July 2010 (94)
We have redone a low frequency measurement (0.01 hz to 0.1 Hz) with much more averages (222) in order to estimate with more accuracy the lower zero moment point offset (distance between the actuators and zero moment point of the rods).

The data is stored in: 100721_LZMP_0p01to0p1Hz_M2M_test2_tfretrieve.mat

The script used to take data is : TFcollect_100721_LZMP_0p01to0p1Hz_30avg.m 

This script does contain 220 averages contrary to what his name says.

The result are presented on the plot attached. The offset estimation is lower than it was:

Last measurement gives:
X offset = 0.24 mm
Y offset = 0.30 mm

versus
X offset = 0.14 mm
Y offset =  0.16 mm
as presented in yesterday entree base on a measurement using only 30 averages.


The numbers we get are very good, and maybe surprisingly low (that's less than .01" offset). However, they are consistently low so that we can conclude that we are good.

Non-image files attached to this comment
X1 SEI
corey.gray@LIGO.ORG - posted 14:43, Wednesday 21 July 2010 (91)
Displacement Capacitive Position Sensors With New BNC Feedthrus
(Eric A., Corey G.)

Over the last few days, we've bypassed our original BNC feed-thrus on our Interface Board, and are now using actual BNC feed-thrus.  The issue here is that the original BNC feed-thrus proved to be troublesome and sacrificed the performance of our Sensors.  We've found that using the "real" feed-thrus (and also buying better/expensive feed-thrus) have made our Sensors perform much better.

Switching to the new feed-thrus has changed the DC value of of our sensors.  At "zero" our Sensors were all under ~1000 counts, but with the new feed-thru the zeroes have increased to around 10,000 counts.  Because of this we had to re-gap the Sensors.  This sort of change required us to re-do a few more Sensor Tests (according to document T1000329).

New Power Spectra for the Displacment Sensors have been run.  The measurement is located here:

/opt/svncommon/seisvn/seismic/HAM-ISI/X1/Data/unit_1/dtt/unit_1/dtt/20100720_all_disp_spectra.xml

Attached are plots of spectra with BOTH Sensor Mini-Racks ON, and with only one ON.
Non-image files attached to this report
X1 SEI
david.barker@LIGO.ORG - posted 14:07, Tuesday 20 July 2010 (90)
how to restore from an autoburt snapshot file
To complete the autoburt alog: how to restore from a snapshot file.

Just 'cd' into the directory containing the snapshot files to be used
for the restoration. Then use the 'burtwb' command, it takes the snapshot
file as an argument.

For example, burt restore g1isihamepics to 14:01 snapshot of jul 20th 2010:

[controls@seiteststand 14:01]$ cd /data/autoburt/2010/07/20/14:01/
[controls@seiteststand 14:01]$ burtwb -f ./g1isihamepics2010072014:01.snap 
X1 SEI
david.barker@LIGO.ORG - posted 14:02, Tuesday 20 July 2010 (89)
autoburt for seiteststand
I have created an autoburt for seiteststand. It works by scanning the target
area for any autoBurt.req files. For each file it finds, it performs a burtrb
and saves the snapshot file in the /data/autoburt area.

The autoburt runs every hour at one minute past the hour (as a cronjob
as user controls on seiteststand). If we need to run at a different rate
this is just a crontab change.

Currently the script (/opt/rtcds/geo/g1/scripts/autoburt) uses the geo/g1
targets. When we move to X1 this will have to be edited.

Here is an example the data directories and snapshot files names:

[controls@seiteststand 14:01]$ pwd
/data/autoburt/2010/07/20/14:01
[controls@seiteststand 14:01]$ ls
g1isihamepics2010072014:01.snap  g1x01epics2010072014:01.snap
X1 SUS
betsy.weaver@LIGO.ORG - posted 11:39, Tuesday 20 July 2010 (87)
LHO Q1 Status
Richard took another look at the EE QUAD test stand and fixed some current issues, such that signals are now back to expected values of ~32k counts.  He also did some work on the satellite box for the AOSEMs, as he determined that jumpers were needed there.
Logbook Admin General
jonathan.hanks@LIGO.ORG - posted 17:32, Monday 19 July 2010 - last comment - 11:44, Tuesday 20 July 2010(85)
Logbook Maintenance - please save your drafts before 10am
The logbook will be unavailable from 10-noon tomorrow.  If you are working on an entry during that period, please save it as a draft before 10am Pacific time.

The logbook will undergo some maintenance tomorrow morning.  This is to fix some layout issues with the quick search area for webkit based browsers (ie Safari and Chrome).

Also it appears that there still is an issue with log session times. It appears that simply extending the Shibboleth SP Session time to a large value is insufficient.  I will attempt another short term fix tomorrow.  Ultimately it must move to a system that will require re-authentication when the Shibboleth session times out.  However it is not quite a quick fix as we must ensure that no data can be lost when handling this.  Likely the user will be given a notice that they must login again, but that their post (if there were any pending) have been saved to a draft.
Comments related to this report
jonathan.hanks@LIGO.ORG - 10:02, Tuesday 20 July 2010 (86)
The logbook is going down for maintenance
jonathan.hanks@LIGO.ORG - 11:44, Tuesday 20 July 2010 (88)
Maintenance has finished on the aLOG.

The following work was done:
* Updated CSS and HTML to better layout the quick search fields on Safari, Chrome, Opera, and Internet Explorer
* Updated the display logic to highlight search terms better.  The search has always been case insensitive, now the highlighting is case insensitive and case preserving.
* Another fix to make sure the author name is always filled out.  This is a temporary fix, a more correct fix will be needed.
* Updated the database to make sure author names matched usernames, ensuring that searching will work properly.
Displaying reports 88521-88540 of 88614.Go to page Start 4423 4424 4425 4426 4427 4428 4429 4430 End