The GRB alerts to LHO have been terminated until further notice. Same goes for the weekly SNEWS test alerts (as well as any real SNEWS supernova alerts...). The GRB alerts are still being sent to LLO, but those will also be terminated soon. GEO: We are set up to send GRB abd SNEWS alerts to GEO, and they will set up soon to receive them, according to H Grote. Virgo: Virgo has its own independent system.
(Eric A., Corey G.) Laid out the hole markings on the floor this morning, & then set up the drill and drilled hole #1 (of 16). Will continue drilling holes first thing in the morning and then work on removing flooring (and glue).
Still ailing from a hashy M0 Right channel which is not the OSEM or cable plugged into the BOSEM, we are still working through the test plan on Q2 (E1000494). Signals went stale on us while working just now so we restarted the bscteststand computer via a ./startqts. We are currently running through the medms gains to see if we have set magnets at the correct orientation.
Removed and stored optical lever power supplies for RM, MMT3, BS, ITMX, ITMY, FMY, and FMX. Above mentioned are stored on the racks of receiving/storage area of the LSB.
The cosmic ray detector was decommissioned. The H1 PSL, H1 TCS, and PCal lasers were turned off. All VEA's were transitioned to laser safe. Cheryl and Aidan began decommissioning the H2 TCS lasers. Crane lift testing and inspection was done at end X and mid Y. Contractors from Apollo started cleaning the crane equipment in the LVEA. Left with Cheryl in LVEA ~ 16:11
LHO VEAs have been transitioned to laser safe; PSL, TCS, and PCal lasers are deactivated and locked/tagged out.
The LHO cosmic ray detector (CRD), which was on the floor beneath the ITMY chamber, was removed. A cable tray support was temporarily unbolted from the floor and displaced to allow the CRD to easily slide out. The CRD is currently sitting on the floor of the clean storage room, pending a choice of storage location. (Note that the CRD consists of two pieces with the upper resting on top of the lower piece. So the two pieces should be carried separately.) - Ray, Filiberto, Ryan
To support aligo install, two new alog tasks under the "IFO and SubSystems" section were added: . H2 INSTALL . LHO Facilities
The following machines related to science mode were powered down: projector[0,1,3] h0grbsn h1binj h1injection.
found the problem which was preventing ntp client from running on the sei frontend. There was an entry in the /etc/ntp/step-tickers file (was a caltech address) so I had to add the GC NTP server's address to this file. Seems that if this file is empty, ntp would also work. I kept the ntpdate crontab running on the workstation (every minute) and that machine is time shifting a lot to keep up with the front end (shifts of 0.1 second every minute are common). Not sure what's up with that, I have now turned off the crontab and ntpd is running sync'ing with the GC server also.
The remote power control unit in the right hand DTS rack (the one with dtsboot in it) was given the ip address 10.11.0.100 and put on the dts network. It controls the power to both supplies in dtsfe2,3 and also the Dolphin unit. It can be accessed by port 8100 on badger.
I fixed the problem with awgexc_run for the long signal injections that Vincent has been trying to run using Matlab. The issue was that the SIStr library of routines used by awgstream, awgexc_run, and multiawgstream was eventually attempting to send data to the awg too soon. The awg has a limited amount of memory that it uses to store a waveform - the trick is to send data fast enough that the awg doesn't run out of data, but not so fast that the awg's buffer would fill up. When using the SIStr library to send data to the awg, the library loads the awg buffers full, then before attempting to add more, the library calculates a "sleep" time that is needed to wait before trying to send additional data. After close to an hour of adding data, the library miscalculated and sent the data too soon. The error was not handled gracefully, causing awgexc_run to exit. I fixed the problem on the test stand by shortening SIStr's lead time, to keep it from sending data to the awg so far in advance. I will be examining the data I collected in debug mode to see what the trend of the time calculation is (for possible error accumulation). I will also see if SIStr should be changed to handle the case of attempting to send data that is "too far in the future", as this shouldn't necessarily be a fatal error if the waveform data is part of a long stream of data and it's possible to wait a bit longer to resend the data.
We've noticed that quite a few (5 of the 16 used today) BOSEMs had the screws loose which hold the connector to the body. It was noticeable when plugging in the connector to the head and watching the whole connector wiggle.
After returning the sat boxes to the rack, M0 F1 was glitchy. Filiberto reseated the cable at the Sat box which appeared to fix it. Now hours later, we are aligning the BOSEMs and have found that this signal peggs at ~6k alot. We have been able to fix it by reseating the cable at the sat box, but this is not working right...
M0 F1 still a problem this morning. Filiberto thinks that the Sat box looks like an OP amp blew again - he's pulling the box again for a trip to the ER, er I mean EE.
Filiberto returned the sat box after another Op Amp swap, but a few hours later we now see bad BOSEM signals in this module...
Day 5: Still working on diagnosis of crazy signals from the Sat box 1 (M0 F1, F2, F3, L). With Filiberto, performed another round of boots to the AA chassis, and bscteststand computer. No changes so far. Likely another blown op amp on Sat box 1. Since we seemed to have changed both satellite boxes and a set of cables (put the new Jay cables in), we might have possibly had more than one problem to diagnose. We decided to put back in the old cables on a different sat. box and things looked pretty good. Filiberto is going to fix the blown op amp on the Sat box 1.
After rearranging sat boxes, Richard and Filiberto found 2 that seem to work. They hauled away those that have issues. With the working sets, I finished aligning all 6 M0 Top BOSEMs. I just have to finish setting them to 50% OLV and then we can start FFTs.
Betsy, Here is a summary of the troubleshooting of the Sat units. Oct 8, 2010 Uninstalled two Satellite units SN320073 and SN320078 from test stand. SN320078 had two bad channels. CH1 had gain off by ~6dB. Replaced IC103 (OP2177AR) with OP284. Did not have OP2177AR replacement part but has been placed on order (expected arrival date 10-14-2010). CH3 had output railing high, replaced IC303 with OP284. SN320073 had CH4 output railing high. replaced IC403 and IC404 with OP284. Ran test on units per Test Plan T080062 - UK Satellite Amplifier Pre-Preduction Test Plan for transfer functions and voltage readings. Oct 11, 2010 Reinstalled SN320073 and SN320078 in test stand. Took opportunity to test unit SN3200715. Tested unit per Test Plan T080062 - UK Satellite Amplifier Pre-Production Test Plan. All test results within specs. Reinstalled unit back in test stand. Oct 12, 2010 While connecting OSEM's Betsy and company found MO F1 signal to be glitchy. This corresponds to unit SN320078 CH1. While trouble shooting, switched cables with another sat unit. When reconnecting cables to original sat unit, CH1 not responding, output ~2.3V. Uninstalled SAT unit SN320078 and placed a working unit in its placed. Replaced the "new" cable and installed an older cable on the vacuum side. Connected all four OSEM's and saw a response from all four channels. Disconnected SAT unit and left all four OSEMS connected. Replaced IC103 with OP284. This IC was one that had been previously replaced. Ran transfer functions on CH1 per Test Procedure T080062. Unit tested good. Used spare cable and OSEM SN0011 from Betsy to test connecting and disconnecting osems while sat powered on. Trying to see if the act of plugging and unplugging the OSEM could be causing opamps to go bad. Oct 13, 2010 Reconnected unit SN320078, knowing that all four OSEMs were connected, we expected to see all four channels come up. Upon powering unit up, all four channels seemed glitchy until CH3 died. All other channels then settled to a good state. Unit SN320073 also had CH4 fail again. Oct 14, 2010 Replaced IC103 (CH1) and IC303 (CH3) on unit SN320078 with OP2177. Replaced IC402 and IC404 on CH4 with OP2177. All opamps that were continually going bad were the OP284. Since they were being used as substitutes until OP2177 arrived. Oct 15, 2010 Took readings of OSEMs. SN # Our Readings Stuart's Reading Symptoms SN688 55.44 57.6 Working Unit SN695 61.08 62.67 Glitchy - Case causing short SN674 48.99 49.51 Low Count SN697 54 55.37 Working Unit - 29K Count Data corresponds with Stuart's data. Even OSEM SN674 shows a lower voltage reading that is consistant with the low count reading from MEDM. Looked at the bad OSEM with the short. The short is coming from the Photodiode Cathode side. Also, we connected and disconnected various OSEMs and don't seem to be having the issue of blowing up the Opamps. Still not sure how the first set of Opamps went bad.