jeffrey.kissel@LIGO.ORG - posted 14:08, Thursday 16 April 2026 - last comment - 14:15, Thursday 16 April 2026(89919)
h1spih23 Front-end Model Bug Fix for ADC3 map of REF and MEAS PDs
J. Kissel

As I'm building up the MEDM screens for SPI, I'm finding some bugs in the Simulink model. This one: 
According to D2400111-v6, and the ADC/DAC Channel Usage Table in G2401479-v3, ADC3 CH20 = PWRIN_REF and ADC3 CH21 = PWRIN_MEAS. 

The initial release of the SPI model at LHO (LHO:89777, ${USERAPPS}/spi/h1/models/h1spih23.mdl userapps svn rev r34928, ${USERAPPS}/spi/common/models/SPI_LIBRARY.mdl rev r30005) had these flipped with ADC3 CH20 = PWRIN_MEAS and ADC3 CH21 = PWRIN_REF.
 
I've fixed the bug, and the top level and library are now at rev r35060 and r35059 respectively, and Dave's installing / restarting for me. No DAQ restart required, as it's just simulink wires getting uncrossed.
Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 14:15, Thursday 16 April 2026 (89920)

The only issue we had with the install was a file permission on the filterfile userapps/spi/h1/filterfiles/H1SPIH23.txt (was not controls group writable). After fixing the permissions the install proceeded normally and the model was restarted at 14:07 with no DAQ restart needed.

H1 SEI (SEI)
ibrahim.abouelfettouh@LIGO.ORG - posted 14:07, Thursday 16 April 2026 (89918)
HEPI Pump Trends - Monthly FAMIS 39955

Closes FAMIS 39955

Last checked in alog 89599.

All trends look consistent and/or similar with last month's with the exception of the EX pump, which Jim commented on last time. This pump was seen going up in pressure. This pressure has since remained stable.

LHO FMCS
ibrahim.abouelfettouh@LIGO.ORG - posted 13:37, Thursday 16 April 2026 (89917)
Checking HVAC Fans - Weekly FAMIS 39863

Closes FAMIS 39863. Last checked in alog 89728.

EY_FAN2_470_1 (green) and both EX fans are going through some quiet lapses that were only seen once in the last alog. Nothing is near the "noisy" threshold though.

Plots attached.

Images attached to this report
LHO VE
david.barker@LIGO.ORG - posted 10:28, Thursday 16 April 2026 (89914)
Thu CP1 Fill

Thu Apr 16 10:10:09 2026 INFO: Fill completed in 10min 6secs

 

Images attached to this report
LHO General
ryan.short@LIGO.ORG - posted 07:40, Thursday 16 April 2026 (89912)
Ops Day Shift Start

TITLE: 04/16 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
    SEI_ENV state: MAINTENANCE
    Wind: 20mph Gusts, 13mph 3min avg
    Primary useism: 1.01 μm/s
    Secondary useism: 0.27 μm/s 
QUICK SUMMARY: More work in BSC2 planned for today to prepare for dome and cartridge removal. A M6.0 earthquake from New Zealand is passing through.

H1 SEI
jim.warner@LIGO.ORG - posted 17:17, Wednesday 15 April 2026 (89911)
HEPI Springs mostly unloaded today.

This afternoon Mitch and I went to the chamber and after putting a little extra pressure on the locking screws, we started taking tension off of the springs. All springs started around 2k lbs each, we left them with about 400lbs each. Before transferring load to the stops, I used the screws to push HEPI about 100 um above the reference position. RX,RY and RZ were all within 25urad, X&Y were about 80um away from the reference. Right now Z has settled about 100 um below the reference position, all of the other positions are nearly unchanged. First thing in the morning we will drop all of the springs to ~150lbs each and re-assess the position. If things are still good we will attach dial indicators and get ready to remove the actuators.

First attached image are the after (left side readouts) and before (right) IPS readings. Second image are the cartesian IPS locations in nm or nrad, left column is after spring relief, right is before.

Images attached to this report
LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:51, Wednesday 15 April 2026 (89910)
OPS Day Shift Summary

TITLE: 04/15 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
INCOMING OPERATOR: None
SHIFT SUMMARY:

IFO is in IDLE and MAINTENANCE

Did not end up taking the dome off but went in for more measurements/FARO of the beamsplitter. Most of the setup from dome removal is done and dome removal is slated for tomorrow.

LOG:

Start Time System Name Location Lazer_Haz Task Time End
14:35 FAC Kim, Nellie LVEA N Technical cleaning 15:53
15:08 IAS Ryan C LVEA N FARO Startup 15:12
16:01 FAC Tricities Asphalt MY N Asphalt-ing 20:01
16:17 SUS Randy LVEA N Handrail BSC and craning 17:03
16:20 FAC Kim EX, MX N Technical Cleaning 18:02
16:36 IAS Ryan C, Jason LVEA N FARO 18:10
16:37 PEM Robert EX n Grounding himself 20:26
16:50 EE Fil MER N Rack Cabling 18:01
17:02 TCS Camilla, Madi Optics Lab N Grabbing parts 17:46
17:13 TCS TJ EX Y HWS Work 19:14
17:13 SUS Jim LVEA N FARO Support 18:01
17:35 VAC Travis LVEA N Turbopumps out at 1900 19:19
17:46 TCS Camilla, Madi EX Y HWS work 19:14
18:01 VAC Jordan, Gerardo LVEA N North Bay Craning 18:57
18:01 EE Fil LVEA N Cabling 19:39
18:10 OPS Corey Optics Lab N Part search 18:25
18:28 FAC Randy LVEA N Craning out at 1900 19:19
18:28 SEI Jim LVEA N Poking HAM4 HEPI 18:32
18:44 OPS Oli LVEA N Look at West bay camera placement 18:57
19:39 EE Fil MER N Cabling 22:38
19:53 SUS RyanC CR N ETM OPLEV charge measurements 22:03
20:35 VAC Travis, Gerardo, Jordan LVEA N GV5 work 21:42
20:39 SUS Betsy, Jason, Ryan C LVEA N Scale measurements 22:39
20:47 TCS Madi, Camilla LVEA N Bugging Travis 23:33
20:51 SUS Corey LVEA N Photo Op 22:06
21:00 TCS Camilla, Madi Optics Lab N Turning on eyesafe green laser 22:00
21:09 FAC Randy LVEA N Joining Corey 21:25
21:10 SEI Jim BSC2 N BSC2 HEPI Work 23:10
21:50 OPS Oli LVEA, Optics Lab N Ruler transport 22:06
23:34 TCS Madi, Camilla Optics Lab   Testing eye safe laser 00:04
H1 INS
betsy.weaver@LIGO.ORG - posted 16:47, Wednesday 15 April 2026 (89909)
More measurements of BS vs cage position in chamber
This afternoon, Ryan C and I hopped into BSC2 (via BSC1) and took a few more measurements of the optic position relative to the cage for Jason and the IAS mapping.  Jason will periodically post some data which consolidates these more nicely visually.  In the end, we found the BS optic rotated clockwise in it's cage a small amount (likely how we installed it), namely 1mm out of plane from one side to the other.
H1 SUS (SUS)
ryan.crouch@LIGO.ORG - posted 16:34, Wednesday 15 April 2026 (89906)
OPLEV charge measurements, ETMX, ETMY

I retook the ETM OPLEV charge measurements this afternoon after the changes we made last week (HV switched off for ETMY digitally, and the sign of the bias offset flipped for ETMX from alog89809). I'm not sure why the error is larger on EX than EY, the wind was medium high but that would effect EY more than EX, the ends were seeing similar ground motion in the 0.03 - 0.1 band. I had no issues running the script, I switched it from scipy to numpy last week.

The sign change appears to be successful in reducing the charge on ETMX, every DOF/quadrant saw its' charge reduced from last week. We will be trying to measure this weekly now to confirm and possibly fine tune the settings.

ETMYs' charge looks to be  approximately the same as the last measurement, although 2/3 of the DOF/qs saw a small trend away from zero of <5 [V] at most compared to last week. The trend of the charge on EY from Nov (previous measurement) to last week was toward zero on all DOF/qs but there was a much larger time difference between those two sets of measurements (~five months vs ~a week).

Images attached to this report
H1 ISC
marc.pirello@LIGO.ORG - posted 13:55, Wednesday 15 April 2026 (89905)
EX Kepco Power Supply Replaced

Following up on this report ALOG89822 and this work permit WP13164 we replaced two Kepco Power Supplies at EX.  These supplies source power to ISC and TCS racks in the EX CER room.

The +/- supplies were still running but the fan on the -18V supply had siezed up, and the supply was overheating.  The +18V supply seemed ok, but when I turned them both off it would not restart.

The +18V supply is now S1201904 has improved fan installed.
The -18V supply is now (no serial number) has improved fan installed.

Both supplies were set back to their original voltage configurations and power sequenced back on, this was completed yesterday afternoon.  The pulled supplies will be upgraded with new fans and placed back into spares inventory.

H1 PSL
ryan.short@LIGO.ORG - posted 13:48, Wednesday 15 April 2026 (89904)
PSL 10-Day Trends

FAMIS 31133

On Friday, h1psl0 was rebooted as part of updates to its timing card firmware and RCG (see alog89859), which unlocked the PMC briefly and left the ISS off (on purpose, the autolocker is turned off in SDF so that it can be turned on later once the PMC thermalizes). It looks like the PMC (as usual) relocked at a slightly different temperature; it doesn't appear to have much effect this time on the transmitted power, but the reflected power is very slightly lower. I've turned the ISS autolocker back on.

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 10:48, Wednesday 15 April 2026 (89903)
Subversion server down for upgrades

Nyath, Jonathan:

Nyath has started the upgrade of the subversion repository server. This service will be down for a few hours.

LHO VE
david.barker@LIGO.ORG - posted 10:16, Wednesday 15 April 2026 - last comment - 10:19, Wednesday 15 April 2026(89901)
Wed CP1 Fill

Wed Apr 15 10:09:01 2026 INFO: Fill completed in 8min 58secs

 

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 10:19, Wednesday 15 April 2026 (89902)

The alog LOG-OUT has a problem, Jonathan is working on a solution.

H1 SUS
ibrahim.abouelfettouh@LIGO.ORG - posted 23:24, Tuesday 14 April 2026 - last comment - 16:44, Wednesday 15 April 2026(89891)
ITMY ITMX and BS Oplev Trend since last DRMI

Attahed and in the table below are oplev positions for ITMY, ITMX and BS since last DRMI lock on 03/19/2026 at 11:02 PDT

  DRMI Locked Reference Latest
  11:02 PDT 03/19/26 15:00 PDT 04/14/26
BS P Oplev 2.10 0
BS Y Oplev -25.92 0
BS Sum Oplev 20215.30 19605.8
IX P Oplev -10.70 -3.64
IX Y Oplev 5.10 -1.2
IX Sum Oplev 3188.52 4.7
IY P Oplev -26.65 42.5
IY Y Oplev -3.22 22.92
IY Sum Oplev 7904.27 4731.59

Note 1: The BS Oplev Damping loops were still on during some FARO work and were shaking the BS. We turned these off on morning of April 14.

Note 2: The right-most T-cursor marks the corner-station vent

Images attached to this report
Comments related to this report
ibrahim.abouelfettouh@LIGO.ORG - 16:02, Wednesday 15 April 2026 (89907)

Note that gate valve closure means that IX oplevs would read a 0 sum. This is expected.

betsy.weaver@LIGO.ORG - 16:44, Wednesday 15 April 2026 (89908)
Also, since this alog, Jeff/Ibrahim flipped the BS OPLEV Damping Servo OFF via the damping filter bank buttons, and re-turned-on the output buttons of the main banks, so those Pit/Yaw channel values bounced back up from 0 to more reasonable values.
LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 15:26, Tuesday 07 April 2026 - last comment - 10:13, Tuesday 21 April 2026(89806)
HAM1 -Y Door Report

(Travis, Randy, Gerardo)

On Monday, the -Y door went on the HAM1 chamber with some minor issues not noted on previous installations, for some reason we had two minor misalignments: one, the door did not hung parallel to the HAM's flange,small tilt towards the outside on the upper part of the door, maybe the pick point slid forward.  Two, the door required a clocking move, we pinned two holes spanning 5:12 O'clock, then rotated the door clockwise a bit until all of the holes aligned, then a small movement on the -Z to complete the alignment about 1/8".  After all of that the door looks pretty concentric to the chamber flange.

Something to note, a dirty glove was found inside the chamber, yes inside the chamber under the support tube on the -Y side of the chamber, as I write, I nod, because it does not take much time to get this dirty thing out of the chamber.

 

Images attached to this report
Comments related to this report
jordan.vanosky@LIGO.ORG - 16:35, Tuesday 07 April 2026 (89814)

HAM1 +Y door was installed today after replacing the inner o-ring, which had fallen out during door removal.

O-ring install went fairly smooth, only popped out of the groove a couple times, but we were able to get it seated properly and continued with door install.

No issues encountered, and we started pumping the HAM1/2 annulus volume to confirm there were no door o-ring leaks. Currently both aux carts are at ~2E-5 Torr.

gerardo.moreno@LIGO.ORG - 13:39, Thursday 16 April 2026 (89866)VE

Update on annulus sytem

Pumping continues with two aux carts, one connected to each chamber (HAM1 and HAM2 annulus), last thursday we turned the ion pumps (see trend data attached), and HAM1 responded well, however the ion pump for HAM2 railed, after a couple of wake up hits it started working.  Currently both systems are doing good, probably they'll be ready to run on ion pumps soon.

Images attached to this comment
gerardo.moreno@LIGO.ORG - 10:13, Tuesday 21 April 2026 (89960)VE

Both aux carts are now removed from the annulus system for HAM1/HAM2.  The annulus system is back to nominal, at vacuum and under ion pump management, the main volume for HAM1 is at atmosphere and ready to pump down as soon as it is requested.

Images attached to this comment
H1 TCS
matthewrichard.todd@LIGO.ORG - posted 09:53, Monday 08 December 2025 - last comment - 14:20, Friday 24 April 2026(88413)
Weekend HWS transients

M. Todd, S. Dwyer, J. Driggers


Summary

Measurement Value [uD / W] Notes
Ring Heater Coupling to Substrate Lens -21.0 +/- 0.3 relative to modeled coupling, 79 +/- 1 % efficiency compared to
predicted 75-80% efficiency from arm cavity measurements.
Modeled couplings assuming 100% efficiency report around -26.5 uD/W.
SR3 Heater Coupling to Substrate Lens

ITMX HWS: 4.7 +/- 0.2

ITMY HWS: 4.6 +/- 0.1

The ITMX HWS seems to be noisier than ITMY, but give very similar mean estimates.
The estimate from Gouy phase measurements is around 5.0 uD/W.

We turned on inverse ring heater filters to speed up the heating for those (using nominal values for the settings). Because of the weekend mayhem with the earthquakes we did not get a SUPER long HWS transient measuring the full response, but we could get a pretty good estimate of the ring heater effect on the substrate thermal lens without any other heating in the measurement. This is good to compare to modeled values that we have.

I also turned on SR3 heater on Sunday to get estimates of the coupling of SR3 heating to the defocus of SR3. To do this, Jenne helped me untrip a lot of the SU watchdogs for the relevant optics to the HWS. About 3 hours after the SR3 was turned on the watchdogs must have tripped again and misaligned the optics. But fortunately we got the cooldown data for this as well and it's all pretty consistent. These measurement suggest a 4.7 uD/W coupling for SR3 heating, which is very similar to modeled coupling from Gouy phase measurements at different SR3 heater powers.

Overall, while these measurements provide more pieces to the puzzle, they make previous analyses a bit more confusing, requiring some more thought (as usual).

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 10:00, Wednesday 15 April 2026 (89900)

In the estimates for SR3 heater above, Matt is using the requested power on SR3 to do the estimation, which is higher than the reported power.  

For both the October 2019 Gouy phase measurement and for the December 2025, the SR3 requested power was 4 W while the readback power was 3.2W.  

I used the same cool down time that Matt used above, reading 38uD change in spherical power from the X HWS and 34.5uD, if we use the reported power change of 3.2W we get 5.9 uD/W reported by HWS X and 5.4uD/W reported by HWS Y.  

sheila.dwyer@LIGO.ORG - 14:20, Friday 24 April 2026 (90002)

When Matt quotes uD/W for the ring heaters above, he is talking about total ring heater power, while the ndscope screenshot he attaches shows per segment power.  

So he arrives at his 21uD/W = (change of 36uD/(2segments*0.44Watts per segment))/(factor of 2 for going from spherical power to defocus). 

This is about twice the actuation strength measured in 89038, which agrees with the number and the simulation in Matt's thesis, and the value of -9.9uD/W used in finesse. 

For a similar measurement of the CO2 heating, see 89999

H1 TCS (ISC, SQZ)
jennifer.wright@LIGO.ORG - posted 16:33, Monday 04 August 2025 - last comment - 09:43, Wednesday 15 April 2026(86184)
Calculating curvature of SR3 when heated up by 2W.

Jennie W, Camilla C

 

A while ago we heated up then cooled down the SR3 heater (alog #84749).

As part of measurements using this data I calculated the curvature change, following the approach at LLO by Aidan given iin alog #27262. Matlab code is below.

 

%calculate SR3 spherical lens

Pin = 2;%W

double_pass = 2;

SR3_t = (3*3600) + (11*60); % Time for cooldown in s.

delta_ITMY = -2.67e-5;% decrease in defocus of ITMY according to Hartmann sensor.

D_ITMY = delta_ITMY./double_pass;% defocus change in Dioptres

D_ITMY_error = 5e-6;% error on defocus in Dioptres.

R_SR3 = 36.013;% cold radius of curvature in m

delta_R = (2./((2/R_SR3)+D_ITMY))-R_SR3; % change in curvature during cooldown in m/

delta_delta_R = D_ITMY_error.*(2./((2./R_SR3)+D_ITMY)); % error on curvature change.

 

This means the rate of defocus change is 6.6750uD per Watt.

The final curvature change is + 0.0087 m +/- 0.0002 m as the mirror becomes less curved due to cooldown.

 

Comments related to this report
sheila.dwyer@LIGO.ORG - 09:43, Wednesday 15 April 2026 (89899)

In 84749Camilla had a look at the HWS images from these times, and I think her conclusion is that we shouldn't trust the reported spherical powers that Jennie is using above to estimate the curvature change.  Matt later redid a HWS measurement using the SR3 heater heater, in 88413, we can use the value from that alog for uD/W instead and scale that to the power used here.\

In the time that Jennie is using above, the SR3 heater is set to 2W requested power, but the power readback reports 1.9W.  