Displaying reports 1881-1900 of 88654.Go to page Start 91 92 93 94 95 96 97 98 99 End
Reports until 13:06, Monday 02 March 2026
H1 PSL
ryan.short@LIGO.ORG - posted 13:06, Monday 02 March 2026 (89322)
PSL 10-Day Trends

FAMIS 31127

Jason made a brief trip into the enclosure 4 days ago, which is seen in the usual places. Also, the differential pressure between the laser room and anteroom changed around that time. Nothing much else to report this week.

Images attached to this report
LHO General
ryan.short@LIGO.ORG - posted 07:38, Monday 02 March 2026 (89320)
Ops Day Shift Start

TITLE: 03/02 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
    SEI_ENV state: MAINTENANCE
    Wind: 3mph Gusts, 0mph 3min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.14 μm/s 
QUICK SUMMARY: The HAM1 annulus has been pumping over the weekend, and if that's reached a low enough pressure, then pumping can start on the HAM1 main volume today. A few decent-sized earthquakes rolled through overnight as well.

LHO VE
david.barker@LIGO.ORG - posted 10:23, Sunday 01 March 2026 (89319)
Sun CP1 fill

Sun Mar 01 10:09:25 2026 INFO: Fill completed in 9min 21secs

 

Images attached to this report
LHO VE
david.barker@LIGO.ORG - posted 10:12, Saturday 28 February 2026 (89318)
Sat CP1 Fill

Sat Feb 28 10:10:32 2026 INFO: Fill completed in 10min 28secs

 

Images attached to this report
H1 TCS
sophie.muusse@LIGO.ORG - posted 17:56, Friday 27 February 2026 (89315)
CHETA Updates

S. Muusse, G. Valente


Electronics integration

We are running into some issue with the linear translation stage and rotation stages which we can't operate through the medm. Both stages are operational when using a newport motor driver and when driven through directly through beckhoff into the CHETA chassis and motor driver chassis but havent been shown to work with the code taken from the CO2 rotation stages. Patrick has been looking through the software but we are yet to find the solution. Yesterday (02/26) we determined the motor power cables from the CHETA chassis to the motor driver chassis were crossed which was a possible source of this issue, however, this was consistent with the wiring in the motor driver chassis albeit unorthodox. We elected to modify the cables so they are wired conventionally and in turn changed the wiring in the motor driver chassis by switching the + and - wires at the back of the chassis where the power is outputted. Now internally  the black = positive and red = Negative which is unfortunate but the best solution. We have seen both stages work after this effort using the newport motor driver so we dont believe this is the issue. 


Setting up Table 2

Table 2 is in the process of being populated. Today we installed the PD system using the electronics to align the PDs and also have inserted the first telescope lens. Initially, when installing and aligning the PDs the PD power supply chassis was supplied with pos =+24 and gnd =0V instead of ±18V leading to both PDs outputing -11V. This fried the first transimpedence amp in the circuit board which we have now replaced with alot of help from Marc. Both PDs are now working and aligned on the table. 


Calibration and power budget on table 1

We measured the power after all optics, where the powermeter fit ,as well as the I[A]/P[W] relationship of the laser to calibrate laser power on the MEDM.
The min/max power that can be achieved using the waveplate in rotation stage and the 2 polariser was measured:
Min ≈20mW ,
Max = 1.44W 
Both powers were measured after the 2nd polariser. This corresponds to a maximum power which can be output off the table of 1.308W, which was measured after the last pickoff. 
I'll attach plots/ figures in the comments showing these measurements.

H1 CDS
jonathan.hanks@LIGO.ORG - posted 17:10, Friday 27 February 2026 (89314)
WP 13002 Migrate services to the new VM cluster

As part of WP 13002 we migrated more services from the old VM cluster to the new one.  The most visible one was migration of the dust monitor and weather station IOCs.

We waited to do this migration until the doors were back on to make sure the dust monitors did not disappear while they were needed.

We have one more VM to migrate, we will do that on Monday and then de-commission the old VM cluster and supporting file servers.

LHO General
ryan.short@LIGO.ORG - posted 16:44, Friday 27 February 2026 (89310)
Ops Day Shift Summary

TITLE: 02/28 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
INCOMING OPERATOR: N/A
SHIFT SUMMARY: Both doors and all viewports are now in place on HAM1 and the annulus is pumping down. Next week, after the main volume is at low enough pressure, we'll start commissioning the new JAC in with the rest of the IFO.
LOG:

Start Time System Name Location Lazer_Haz Task Time End
15:36 FAC Kim, Nellie LVEA N Technical cleaning 16:19
15:46 FAC Randy LVEA N Prep for HAM1 door 16:31
16:09 VAC Jordan LVEA N Isolate turbopump on BSC8 16:17
16:49 VAC Travis LVEA N HAM1 viewport and door prep 17:34
16:50 VAC Jordan LVEA N HAM1 viewport and door prep 17:34
16:50 FAC Kim, Nellie LVEA N Technical cleaning 18:03
17:10 SAF Richard LVEA N Checking in w/ VAC team 17:32
17:48 FAC Randy LVEA N Measuring cleanrooms in W-bay 19:48
17:54 SPI Jeff Opt Lab Local SPI fiber characterization 20:11
17:55 VAC Jordan, Mitchell LVEA N Prep for HAM1 cleanroom move (Mitchell out @ 18:11) 19:27
17:57 VAC Betsy, Travis LVEA N HAM1 door and cleanroom move (Betsy out @ 18:12) 19:27
18:25 TCS Sophie, Gabriele Prep Lab Local CHETA table work 18:45
18:49 FAC Kim LVEA N Technical cleaning 19:35
18:51 SAF Richard LVEA, CER N Safety checks in walls 18:58
18:54 TCS Sophie Prep Lab Local CHETA table work 20:03
20:22 SPI Jeff, Jim Opt Lab Local SPI fiber characterization (Jeff out @ 23:30) 23:38
20:29 FAC Randy LVEA N Craning scissor lift 21:10
20:37 VAC Jordan LVEA N Setting up HAM1 pump carts 21:38
20:42 VAC Travis LVEA N Setting up HAM1 pump carts 21:38
22:15 SQZ Sheila LVEA N Turning on SQZ laser 22:45
22:45 VAC Travis LVEA N Checking HAM1 pumps 23:03
22:54 TCS Gabriele, Sophie Prep Lab Local CHETA table work (Gabriele out @ 23:15) Ongoing
23:08 JAC Jennie, Keita LVEA N Checking parts, turning off JAC heater (Keita out @ 23:40) 00:08
00:23 ISC Elenna, Oli Opt Lab N Assembling optics Ongoing
H1 CDS
david.barker@LIGO.ORG - posted 16:35, Friday 27 February 2026 - last comment - 09:38, Monday 02 March 2026(89312)
CHETA slow controls chassis now connected to MSR chassis by copper the whole length

Richard, Marc, Jonathan, Erik, Dave:

On Monday 23rd the CHETA slow controls chassis was installed in the Vacuum Prep Lab (VPL). We connected its ECAT ethernet port to the MSR Beckhoff chassis AUX-1 port partially by copper (VPL to Rm163 into CUR) and partially by fibre (CUR CDS edge switch to MSR edge switch).

This appeared to work, but later we found out that the CDS core switch was complaining constantly of rapid movement of a MAC address on the ports used by CHETA. Further reading suggests ECAT does not strictly support unique MAC addresses per Beckhoff terminal, and it appears they may all have the same non-standard MAC address.

In addition, since Monday we have been seeing regular dropouts of the CUR network switch stacks, every 6 hours at 00:41, 06:41, 12:41 and 18:41 for about a minute apiece.

This afternoon we ran a long 148' cat5e ethernet cable from room 163 to the far end of the MSR. At 16:01 we routed the CHETA chassis connection to use this cable, we now have contiguous copper run between the two chassis.

This will fix the MAC movement issues on the CDS core, and time will tell if if fixes the CUR switch dropout.

Comments related to this report
david.barker@LIGO.ORG - 08:58, Saturday 28 February 2026 (89317)

Initial reports suggest the 6-hourly drop outs of sw-cur-aux-stk has been fixed by this move.

daniel.sigg@LIGO.ORG - 09:38, Monday 02 March 2026 (89321)

EtherCAT terminals do not have MAC addresses. Typically, the network adapter sends an Ethernet frame with its own Ether type that will flow through all terminals without being absorbed. Terminals will just read or write individual bits and bytes of this frame as it passes by, and eventually this frame will be reflected back to the adapter. This is called EtherCAT direct mode and has very good latency characteristics, but it is not comaptible with an IP based infrastructure.

H1 IOO (INS, IOO, ISC)
keita.kawabe@LIGO.ORG - posted 16:25, Friday 27 February 2026 (89311)
Preparing JAC/HAM1 electronics for pumpdown (Jennie, Keita)

JAC PZT: H1:JAC-PZT_DRIVER_OFFSET was set to zero, PZT scan was disabled, and the high voltage power supply for JAC PZT driver between the PSL room and the ISC R4 was turned off.

JAC Heater: H1:JAC-HEATER_POWER_SET was set to zero (used to be 1) and the heater driver chassis (ISC R4 slot 23) was turned off. 

HAM1 picos: HAM1+HAM3 picomotor controller was disabled via medm screen.

H1 PSL
ryan.short@LIGO.ORG - posted 15:40, Friday 27 February 2026 (89309)
PSL Status Report - Weekly

FAMIS 39753

Laser Status:
    NPRO output power is 1.845W
    AMP1 output power is 70.51W
    AMP2 output power is 138.5W
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 2 days, 4 hr 16 minutes
    Reflected power = 27.05W
    Transmitted power = 103.9W
    PowerSum = 131.0W

FSS:
    It has been locked for 0 days 4 hr and 23 min
    TPD[V] = 0.4902V

ISS:
    The diffracted power is around 3.7%
    Last saturation event was 2 days 4 hours and 23 minutes ago


Possible Issues:
    PMC reflected power is high

LHO VE (VE)
travis.sadecki@LIGO.ORG - posted 15:18, Friday 27 February 2026 - last comment - 16:01, Monday 09 March 2026(89308)
HAM1 +Y door installed

The HAM1 +Y door was installed today.  Installation went smoothly and the O-ring cooperated by staying in place today.  I will note that torquing the door bolts is becoming more of an issue due to wrench access being increasingly limited near the 5-way cross/feedthru areas now that all the in-air cables have been attached.

The HAM1/HAM2 annulus system is being pumped by 2 turbos/aux carts on the -Y side of the chambers.  The mysterious ~order-of-magnitude pressure readout difference at the two carts on the shared annulus system is again present, as was noted the last time this annulus system was pumped down.  Not an issue per se, just some vacuum phenomena that leaves us scratching our heads. 

Comments related to this report
gerardo.moreno@LIGO.ORG - 16:33, Friday 06 March 2026 (89415)VE

Vent Recovery Update

Annulus ion pumps for HAM1 and HAM2 continue to pumpdown, we closed the isolation valves for both of them, but the ion pumps were not able to maintain pressure.  On 3/4/26 valves were opened again to continue using the aux carts, and yesterday (3/5/2026) we isolated the aux cart for HAM2 only, all of that can be seen on the attached plot.

Aux carts will be left pumping and annulus systems are going to be evaluated next Monday.

Images attached to this comment
jordan.vanosky@LIGO.ORG - 16:01, Monday 09 March 2026 (89440)

I isolated the HAM1 aux cart (HAM2 was isolated on Friday) from the annulus this morning. The IP current only rose to ~4.7mA before turning around showing it could hold the annulus pressure.

HAM1/2 annulus aux carts were shut down and decoupled this afternoon. The SS500 cart remains at HAM1 and will continue to pump until the pressure is low enough to valve in the HAM1 ion pump.

Images attached to this comment
H1 GRD (CDS, SQZ)
ryan.short@LIGO.ORG - posted 13:23, Friday 27 February 2026 (89306)
CDS_CA_COPY Guardian Fixed

The CDS_CA_COPY Guardian had not been running for roughly the past month due to three disconnected channels reported by SPM (H1:VID-FC_TRANS_A_{X,Y,SUM}). These channels went dead on January 27th when the new VM cluster was installed (alog88919) because they had been running on a dummy IOC called "cam_fc_trans_a_dummy_ioc" (created in March 2024, see alog76146) that must not have been brought over to the new VM cluster. Dave and I decided that since these channels have all been reporting zeroes for almost three years, possibly because that camera is not working, we would simply comment out these channels from the cds_ca_copy_list.txt file so they aren't referenced. After doing that and restarting the Guardian code, the node is working properly again.

H1 ISC
jennifer.wright@LIGO.ORG - posted 12:33, Friday 27 February 2026 (89305)
IMC WFS MASTER updated

Jennie W

 

I updated the medm for the IMC WFS to remove the feedback references to the PSL PZT. This feedback path had been removed from the model this morning (thanks Dave for the rev-locked build of h1ascimc and the DAQ restart). The WFS screen output matrices have been updated to put back the fifth DOF and removed the path to the PZT. We never control this fifth degree of freedom but it is still in the simulin model so we should leave it in. The second picture shows the output matrix screens which no longer contain the PZT feedback column.

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 09:28, Friday 27 February 2026 - last comment - 10:15, Friday 27 February 2026(89299)
h1ascimc model cleanup, DAQ restart

Jennie, Keita, Ryan S, EJ, Dave:

Jennie and Keita did a clean up of the h1ascimc model which was installed this morning. A DAQ restart was required, 14 slow channels had been removed.

As we had seen previously, restarting h1ascimc still causes DAC errors on h1iopasc0, and the safest way to restart h1ascimc is part of a full model restart on h1asc0.

Ryan confirmed a good SDF status and all the models were restarted (h1iopasc0, h1asc, h1ascimc, h1ascsqzifo).

The DAQ was then restarted, no issues other than GDS1 needing a second restart.

Comments related to this report
david.barker@LIGO.ORG - 10:13, Friday 27 February 2026 (89302)

FW1 had a spontaneous restart 10 minutes after the 1-leg restart.

david.barker@LIGO.ORG - 10:15, Friday 27 February 2026 (89303)

Fri27Feb2026
LOC TIME HOSTNAME     MODEL/REBOOT
09:02:27 h1asc0       h1ascimc    <<< first model restart, DAC error on IOP
09:06:53 h1asc0       h1iopasc0   <<< full restart of all asc0 models
09:07:07 h1asc0       h1asc       
09:07:21 h1asc0       h1ascimc    
09:07:35 h1asc0       h1ascsqzifo 


09:12:59 h1daqdc1     [DAQ] <<< DAQ 1-leg
09:13:09 h1daqfw1     [DAQ]
09:13:09 h1daqtw1     [DAQ]
09:13:13 h1daqnds1    [DAQ]
09:13:18 h1daqgds1    [DAQ]
09:13:58 h1daqgds1    [DAQ] <<< gds1 second restart


09:16:17 h1daqgds0    [DAQ] <<< DAQ 0-leg
09:16:23 h1daqfw0     [DAQ]
09:16:23 h1daqtw0     [DAQ]
09:16:24 h1daqnds0    [DAQ]


09:22:03 h1daqfw1     [DAQ] <<< FW1 spontaneous restart
 

H1 AOS
betsy.weaver@LIGO.ORG - posted 16:23, Thursday 26 February 2026 - last comment - 20:21, Friday 27 February 2026(89289)
HAM1 JAC Viewport window re-FirstContact cleaning
Jordan and Camilla pulled the FirstContact from the JAC viewport in prep to install it on the -Y door.  Unfortunately the inner glass surface was still showing many dots of particulate so we decided to re-FirstContact clean it.  I poured on a new sheet and we are now letting it dry overnight.  Install will need to happen tomorrow after we pull the sheet and hopefully have better results.  This seems to be typical of FirstContact these days - needing to reapply a second time on numerous optics...
Comments related to this report
travis.sadecki@LIGO.ORG - 20:21, Friday 27 February 2026 (89316)

The second application of FirstContact was peeled from the vacuum-side of the viewport this morning.  During the peel, the TopGun N2 ionizer output was at ~10 psi, with a follow-up TopGun pass at ~30 psi.  I observed no macroscopic particulate within the ~2.5 inch diameter of the FC coverage after removal.  At the edges of the FC sheet (the ~2.5 inch diameter centered on the viewport optic), I noted two "smudges" of FC film.  I removed these smudges with a small Contec swab dipped in reagent grade acetone.  Another ~1 mm droplet of FC was noted at the optic/mounting ring interface.  I also attempted to remove this with a swab/acetone wipe, but since it was in an interior corner, some FC remained where it had wicked into the interface.

The viewport was then installed on the HAM1 -Y door A2F3 flange.  Torquing of the CF flange and installation of the guillotine assembly went without a hitch.  We didn't do any cleaning to the in-air side of the viewport post-installation.  

LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 00:20, Thursday 26 February 2026 - last comment - 13:54, Friday 27 February 2026(89275)
BSC8 Annulus Ion Pump Replaced

(Travis S., Jordan V., Randy T., Gerardo M.)

Wednesday afternoon we had the opportunity to remove and replace the annulus ion pump body for BSC8 annulus system.  To reach the ion pump body we used the scissor lift that Randy moved near the chamber.
No issues were encountered on the removal or installation of the ion pump body.  The annulus ion pump system was evacuated and we left it pumping down with an aux cart and a small "can" turbo.  On this system we used a noble diode pump, which required us to replace the controller for a positive one.  Setpoints were set on the aux cart and at the end of the day the annulus system had reached below 5.0x10-05 Torr.

Images attached to this report
Comments related to this report
jordan.vanosky@LIGO.ORG - 13:54, Friday 27 February 2026 (89307)

I powered on the ion pump yesterday morning. After pumping with both the ion pump and aux cart overnight, the IP current began decreasing, so I isolated the aux cart this morning. Ion pump was able to hold pressure no problem, so we disconnected the aux cart and brought it over for the HAM1/2 annulus pumpdown. 

H1 SEI
erik.vonreis@LIGO.ORG - posted 11:22, Monday 23 February 2026 - last comment - 11:48, Friday 27 February 2026(89229)
Picket Fence down to four stations

Picket Fence earthquake early warning system can't connect to station "UO_TOOM:HHZ", so we're only monitoring on four out of five stations.

Comments related to this report
edgard.bonilla@LIGO.ORG - 21:20, Thursday 26 February 2026 (89295)

This is strange. We shouldn't be monitoring TOOM. We deprecated it a while ago when we connected to the PNSN.

Line 39 of LHO-picket-fence.py should read:

pickets= ["HLID", "NEW", "OTR", "MSO", "DING"]
Is this correct in your version?

 

erik.vonreis@LIGO.ORG - 11:48, Friday 27 February 2026 (89304)

Edgard's list is correct.  I was looking at some older code.  All five stations are working again.