Displaying reports 4181-4200 of 89162.Go to page Start 206 207 208 209 210 211 212 213 214 End
Reports until 17:10, Tuesday 14 October 2025
H1 ISC
elenna.capote@LIGO.ORG - posted 17:10, Tuesday 14 October 2025 (87473)
Apparent camera offset change

Jenne, Elenna, Oli, Ryan S, Ryan C, Matt

Today the engagement of the camera servos significantly reduced the buildups. The first attachment shows how the PRG, REFL LF and circ power signals dropped as the camera servo guardian engaged the cameras. After reengaging the ADS, we saw that the buildups increased again, although not to the exact same level that they were before the camera engaged. This suggested to us that the camera servos were not going to the same camera set point as before. Oli spoke to the vacuum team that had been doing work at EY and found out that the EY camera cable had been very taut and they tried to loosen it. It's possible they bumped the camera during their work.

While we were considering what to do, we noticed that OMC DCPD sum was increasing rapidly. We realized this was due to a PI ringing up at 10.2 kHz. It's not a PI we usually damp, so there were no PI guardian warnings, and we didn't know how to damp it. Matt thinks this is a PI that we usually see ring up early in the lock, but with a relatively small amplitude, as the Y arm mode passes by. It usually does not need damping. We started getting DCPD saturations warnings, and we were certain we were going to lose lock. We thought perhaps that if we were in a slightly different beam position, that could cause this PI to ring up more than usual. Matt also pointed out that the CO2s had stayed on much longer for commissioning today. I had also held the IFO at 25 W before and after moving spots to perform some ASC measurements. So this was definitely not a normal locking process. However, the PI started to turn around on its own (we think), and we held the lock.

Jenne and I tried engaging the camera servos again, and saw that indeed doing so does reduce the buildups. Our thinking is that if the EY camera got bumped, the digital offset we normally use has probably changed. We also noticed that the low frequency sensitivity was slightly worse than usual, suggesting that wherever the beam was, the A2L decoupling was bad. So, we decided to move the EY camera offsets to see if we could regain the buildups, following the assumption that something had changed at EY. We looked at the camera offset value that was present when the ADS lines were on. We changed the ETMY pitch and yaw offset values. This resulted in a 2 count change for ETMY pitch, from -230 to -228 and a 0.5 ct change in yaw from -349.5 to -349. Changing to these new offsets increased the buildups again. We also saw that the ADS had taken the ETMX camera error signal to a slightly different offset, so we tried changing the ETMX pitch value, but this had no change on the buildups so we reverted.

Even though this whole process was designed to bring us back to the nominal ETMY spot position, it appeared that the low frequency sensitivity was still bad, I ran the A2L script. I watched TJ's A2L script scope and noticed that the A2L starting value for ETMY pitch was very far from zero, so the script never took the A2L value to the minimum. Jenne and I ended up guesstimating what a good A2L value was so that the starting point would be close enough to the minimum that the script steps would go there. This results in a significantly different A2L gain than before for ETMY pitch. I copied the tables below for each A2L script attempt. The nominal ETMY pitch value before was 5.62 and now it is 6.43. According to the a2l lookup script, this is a 3.8 mm change in spot position. The ETMX A2L gains also updated slightly, as you can see below. I did not make any changes to the gains where the diff between final and inital was 0.01 in magnitude.

Now that we have been in NLN for 3.5 hours, the buildups still seem lower than usual. Circulating powers usually read about 382 "kW", but they are currently reading about 374 "kW". Kappa C is also 0.975, and it is usually 0.98. I'm not convinced that the beam is in the correct spot.

Jenne suggested that we could try going back to the old A2L gains, and then adjusting the camera offset until the ADS lines are minimized, which I think is a good idea. However, I do want to point out that our range is currently reading 160 Mpc on sensmon clean.

The new ETMY camera offsets and the updated A2L gains are saved in lscparams and loaded in ISC_LOCK. First try:

Optic DOF Initial Final Diff
ETMX P 3.07 3.13 0.06
ETMX Y 4.79 4.85 0.06
ETMY P 5.54 5.54 0
ETMY Y 1.42 1.37 -0.05
ITMX P -0.45 -0.46 -0.01
ITMX Y 3.16 3.15 -0.01
ITMY P 0.19 0.2 0.01
ITMY Y -2.75 -2.75 0

Second try:

Optic DOF Initial Final Diff
ETMX P 3.13 3.12 -0.01
ETMX Y 4.85 4.85 0
ETMY P 6.3 6.43 0.13
ETMY Y 1.37 1.37 0
ITMX P -0.46 -0.46 0
ITMX Y 3.15 3.16 0.01
ITMY P 0.2 0.19 -0.01
ITMY Y -2.75 -2.75 0
Images attached to this report
H1 General
ryan.crouch@LIGO.ORG - posted 16:29, Tuesday 14 October 2025 (87459)
OPS Tuesday Day shift summary

TITLE: 10/14 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 153Mpc
INCOMING OPERATOR: Oli
SHIFT SUMMARY: We ran into some issues after relocking following maintenance, but everything is stable currently. Is it in the best setup/orientation? Maybe not.
LOG:                                        

Start Time System Name Location Lazer_Haz Task Time End
22:52 SAF Laser HAZARD LVEA YES LVEA is Laser HAZARD \u0d26\u0d4d\u0d26\u0d3f(\u239a_\u239a) 15:51
14:34 FAC Eric Mech room N FAC checks 14:55
14:35 FAC Randy Yarm N Beam tube inspection, midy to corner 18:39
15:08 SUS Jeff CR N ETMX measurements, prep for satamp swap 16:08
15:08 SUS Matt CR N ITM measurements 15:25
15:12 TCS Matt LVEA Y Turn off sidebands 15:25
15:18 FAC Chris Out buildings N FAMIS checks 16:59
15:24 FAC Kim EndX N Tech clean 16:39
15:24 FAC Nellie EndX N Tech clean 16:38
15:25 VAC Gerardo, Jordan EY N Purge air 17:15
15:28 FAC Tyler Yarm N Termination slab checks 19:04
15:31 EE Fil CER Y ITM work 16:11
15:35 OPS RyanS LVEA Y -> N HAZARD TRANSITION, to safe 15:51
16:04 FAC Richard LVEA N Safety checks 16:25
16:05 VAC Anna LVEA N Join RGA team 17:15
16:06 VAC Travis MidX N Emergency pump checks 17:11
16:13 SUS Jeff CR N ETMY measurement 16:51
16:14 EE Fil Ends, X -> Y N Satamp swap, EY at 16:38 UTC 17:22
16:32 ISC Sam LVEA N Measure stuff 17:13
16:33   Keita, Alicia, Joan-Rene LVEA N Tour, take pictures 17:14
16:42 PSL Rahul, Jennie Optics lab LOCAL ISS PD array 18:23
16:43 FAC Nellie, Kim LVEA N Tech clean 18:21
16:51 SUS Jeff LVEA N ITMX SAT amp measurement 17:03
17:00 FAC Chris LVEA N FAMIS checks 17:25
17:22 EE Marc, Fil LVEA HAM5 N SUS R7 rack work, chassis installations 18:59
17:04 SUS Jeff LVEA N SR75 measurement in the Biergarten ITMX 18:05
17:11 VAC Travis MidY N Emergency pump checks 17:42
17:31 FAC Richard, Alicia, Joan-Rene OSB roof N Admire the view 17:47
17:33 VAC Janos, Anna LVEA N Move parts 18:01
17:35 VAC Jordan LVEA N 1000 amu RGA 18:01
17:48 IMC Matt CR N IMC injections 17:54
17:56 IMC Matt LVEA N Sidebands back on 17:58
18:00 TCS Matt LVEA N Turn back on TCS Y 18:10
18:27 VAC Jordan, Anna LVEA N YARM manifold rga 19:02
19:00 TCS Matt LVEA N Reset both CO2 lasers 19:04
19:03 OPS RyanS LVEA N LVEA sweep 19:14
19:24 ASC Elenna CR N Soft ASC loops measurement 21:06
19:49 PSL Rahul, Keita Optics lab N ISS Array work, laser safe 21:46
19:50 FAC Randy Yarm beamtube N Beamtube inspection 21:46
20:42 EE Fil MidY N Grab electronics parts 21:42
21:56   Matt Vac prep lab N Grab a part 22:06
21:56 PSL Jennie Optics lab N Double check something 22:11
Images attached to this report
H1 General
oli.patane@LIGO.ORG - posted 16:17, Tuesday 14 October 2025 (87476)
Ops EVE Shift Start

TITLE: 10/14 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 154Mpc
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 12mph Gusts, 7mph 3min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.18 μm/s 
QUICK SUMMARY:

Observing at 155Mpc and have been locked for almost three hours. Everything looking good.

H1 CDS
david.barker@LIGO.ORG - posted 15:16, Tuesday 14 October 2025 - last comment - 15:24, Tuesday 14 October 2025(87474)
CDS Maintenance Summary: Tuesday 14th October 2025

WP12827 SUS HLTS Estimator

Jeff, Oli, Brian L, Edgard, Dave, Ryan C:

New h1suspr3 and h1sussr3 models were installed. Slow channels had been renamed and therefore a DAQ restart was required.

WP12835 h1guardian1 reboot

TJ:

h1guardian1 was rebooted, all nodes now have the latest userapps files and changes will be tracked by GRD-CFC.

DAQ Restart

Dave, Jonathan:

The DAQ was restarted for the model changes. GDS0 needed a second restart. FW1 spontaneously restarted itself soon after the 1-leg restart.

 

Comments related to this report
david.barker@LIGO.ORG - 15:24, Tuesday 14 October 2025 (87475)

Tue14Oct2025
LOC TIME HOSTNAME     MODEL/REBOOT
08:32:35 h1sush2a     h1suspr3    <<< model restarts
08:33:06 h1sush56     h1sussr3    


08:34:52 h1daqdc0     [DAQ] <<< 0-leg restart
08:35:05 h1daqfw0     [DAQ]
08:35:05 h1daqtw0     [DAQ]
08:35:06 h1daqnds0    [DAQ]
08:35:13 h1daqgds0    [DAQ]
08:36:17 h1daqgds0    [DAQ] <<< GDS0 needed 2nd restart
08:41:11 h1daqdc1     [DAQ] <<< 1-leg restart
08:41:20 h1daqfw1     [DAQ]
08:41:21 h1daqtw1     [DAQ]
08:41:24 h1daqnds1    [DAQ]
08:41:30 h1daqgds1    [DAQ]
08:52:28 h1daqfw1     [DAQ] <<< FW1 spontaneously restarted itself
 

H1 IOO (ISC, PSL)
jennifer.wright@LIGO.ORG - posted 14:00, Tuesday 14 October 2025 - last comment - 08:24, Thursday 16 October 2025(87466)
ISS measurements - 10th -14th October

Jennie W, Keita, Rahul

 

On Friday, Keita and Rahul and I tried moving PDs 2 and 6 to align them better with the others. As can be seen from the scans we did of the DC voltage of the diodes as we moved the input alignemnt in horizontal translation and yaw from alog #87290, 2 and 6 have a range of alignment that is shifted relative to the other 6.

We also checked this with a IR sensitive camera with a zoom lens.

One person used the camera with a zoom lens to check the spot on the PDs as another person loosened the screws from behind the array and the third person held the barrel of the PD assembly to stop it moving or rotating in an undesired direction.

There is not a lot of space as 2 and 6 are in a column and are very close to diodes 1 and 5 on the right.

The horizontal scan we took after these moves showed we had made things worse, see this image.

Later that afternoon, Keita moved the PD 2 back and checked the alignment and it looks better.


The alignment as of yesterday (Monday) was 143mm in pitch (as read out by the allen key in the PZT mirror pitch actuator wheel) and 0.4145 inches in horizontal translation as read out by the translation stage the PZT mirror sits on.

Keita measured the coupling (after finding an error in my code from the previous coupling measurement I plotted last Thursday (alog #87400)).

The coupling in both vertical and horizontal is below 10, so this should be good enough for install if all else checks out.

 

Yesterday afternoon, Rahul and I did the vertical scan (slightly off from the horizontal reference position of 0.4145 inches that Keita had aligned to). The data in this graph was collected at a horizontal translation stage reading of 0.4162 inches.

We had to redo the horizontal scan today as I missed out some scan values yesterday. The data was collected with the pitch indicator at 143mm (the allen key on the pitch wheel actuator).

 

Images attached to this report
Comments related to this report
jennifer.wright@LIGO.ORG - 11:20, Wednesday 15 October 2025 (87471)

This morning Rahul recentred the QPD on the input beam (translation stage = 0.4145 inches, allen key - 143mm) and we scanned the translation stage horizontally to measure the calibration of the QPD.

This first scan had too large steps to give a good estimate of the slope for the X coordinate on the QPD near the centre, so I repeated the measurement with smaller steps. Although I thought I set the laser to ~120 mA for both measurements the power on the QPD sum was slightly different between the two, see this plot where the original measurement set is in orange and the second set in blue.

Looking at the plot the QPD has the same slope in Y for both measurements but the second set of Y measurements has lower voltages.

The X data overlaps between the two measurements which makes more sense to me, as we assume the QPD electronics normalise the readout of X and Y by the sum channel to account for power fluctuations.

I used the newer measurement to estimate the calibration in the x direction, and the older measurement to estimate the slope in the y-direction, I tried to only use the linear part of the data in my fit and also not use any points with a voltage abive 6 Volts as this is when we expect the QPD to not be linear.

The calibration plot is here with the X calibration line in orange and the Y calibration line in red.

The resultant calibration is 72.0 V/mm in the horizontal direction, at an angle of 7.4 deg with the QPD axis. This is similar to the last calibration we did before several moves of the QPD to recentre it, see alog  #87375

This is worked out by adding the two slopes in quadrature and using atan2(Y_calib/X_calib) to work out the angle of the QPD axis with the horizontal direction of the PZT mirror translation.

Images attached to this comment
rahul.kumar@LIGO.ORG - 08:24, Thursday 16 October 2025 (87505)

Attaching a picture of the recentered QPD on the input beam.

Images attached to this comment
H1 SUS
filiberto.clara@LIGO.ORG - posted 13:11, Tuesday 14 October 2025 - last comment - 11:42, Friday 24 October 2025(87469)
Sat Amps Modified: L2 (PUM) Stages for ETMX, ETMY, ITMX, and ITMY

WP 12836
ECR E2400330
Modified List T2500232

The following SUS SAT Amps were upgraded per ECR E2400330. Modification improves the whitening stage to reduce ADC noise from 0.05 to 10 Hz.

Suspension Old New OSEM
ETMX L2 (PUM) S1100146 S1100119 ULLLURLR
ETMY L2 (PUM) S1100137 S1100127 ULLLURLR
ITMX L2 (PUM) S1100135 S1100118 ULLLURLR
ITMY L2 (PUM) S1000277 S1100148 ULLLURLR


F. Clara, J. Kissel, O. Patane

Comments related to this report
oli.patane@LIGO.ORG - 17:22, Tuesday 14 October 2025 (87481)

Here's the characterization data and fit results for S1100148, assigned to ITMY L2's ULLLURLR OSEMs.

This sat amp is a UK 4CH sat amp, D0900900 / D0901284. The data was taken per methods described in T080062-v3, using the diagrammatic setup shown on PAGE 1 of the Measurement Diagrams from LHO:86807.

The data was processed and fit using ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Scripts/
plotresponse_S1100148_ITMY_L2_ULLLURLR_20250917.m

Explicitly, the fit to the whitening stage zero and pole, the transimpedance feedback resistor, and foton design string are:

Optic  Stage  Serial_Number  Channel_Number  OSEM_Name  Zero_Pole_Hz  R_TIA_kOhm  Foton_Design 
ITMY L2 S1100148 CH1 UL 0.095:5.19 120.5 zpk([5.19],[0.095],1,"n")
      CH2 LL 0.0957:5.24 120.0 zpk([5.24],[0.0957],1,"n")
      CH3 UR 0.0958:5.24 120.125 zpk([5.24],[0.0958],1,"n")
      CH4 LR 0.0967:5.28 120.375 zpk([5.28],[0.0967],1,"n")

The attached plot and machine readable .txt file version of the above table are also found in ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Results/
2025-09-17_UKSatAmp_S1100148_D0901284-v5_fitresults.txt

Per usual, R_TIA_kOhm is not used in the compensation filter -- but after ruling out an adjustment in the zero frequency (by zeroing the phase residual at the lowest few frequency points), Jeff nudged the transimpedance a bit to get the magnitude scale within the ~0.25%, shown in the attached results. Any scaling like this will be accounted for instead with the absolute calibration step, i.e. Side Quest 4 from G2501621, a la what was done for PR3 and SR3 top masses in LHO:86222 and LHO:84531 respectively.

Non-image files attached to this comment
oli.patane@LIGO.ORG - 17:19, Tuesday 14 October 2025 (87478)

Here's the characterization data and fit results for S1100119, assigned to ETMX L2's ULLLURLR OSEMs.

This sat amp is a UK 4CH sat amp, D0900900 / D0901284. The data was taken per methods described in T080062-v3, using the diagrammatic setup shown on PAGE 1 of the Measurement Diagrams from LHO:86807.

The data was processed and fit using ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Scripts/
plotresponse_S1100119_ETMX_L2_ULLLURLR_20250916.m

Explicitly, the fit to the whitening stage zero and pole, the transimpedance feedback resistor, and foton design string are:

Optic  Stage  Serial_Number  Channel_Number  OSEM_Name  Zero_Pole_Hz  R_TIA_kOhm  Foton_Design 
ETMX L2 S1100119 CH1 UL 0.0949:5.19 120 zpk([5.19],[0.0949],1,"n")
      CH2 LL 0.0971:5.32 120 zpk([5.32],[0.0971],1,"n")
      CH3 UR 0.0964:5.27 120 zpk([5.27],[0.0964],1,"n")
      CH4 LR 0.0957:5.23 120 zpk([5.23],[0.0957],1,"n")

The attached plot and machine readable .txt file version of the above table are also found in ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Results/
2025-09-16_UKSatAmp_S1100119_D0901284-v5_fitresults.txt

Per usual, R_TIA_kOhm is not used in the compensation filter -- but after ruling out an adjustment in the zero frequency (by zeroing the phase residual at the lowest few frequency points), Jeff nudged the transimpedance a bit to get the magnitude scale within the ~0.25%, shown in the attached results. Any scaling like this will be accounted for instead with the absolute calibration step, i.e. Side Quest 4 from G2501621, a la what was done for PR3 and SR3 top masses in LHO:86222 and LHO:84531 respectively.

Non-image files attached to this comment
oli.patane@LIGO.ORG - 17:18, Tuesday 14 October 2025 (87480)

Here's the characterization data and fit results for S1100118, assigned to ITMX L2's ULLLURLR OSEMs.

This sat amp is a UK 4CH sat amp, D0900900 / D0901284. The data was taken per methods described in T080062-v3, using the diagrammatic setup shown on PAGE 1 of the Measurement Diagrams from LHO:86807.

The data was processed and fit using ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Scripts/
plotresponse_S1100118_ITMX_L2_ULLLURLR_20250916.m

Explicitly, the fit to the whitening stage zero and pole, the transimpedance feedback resistor, and foton design string are:

Optic  Stage  Serial_Number  Channel_Number  OSEM_Name  Zero_Pole_Hz  R_TIA_kOhm  Foton_Design 
ITMX L2 S1100118 CH1 UL 0.0966:5.27 120 zpk([5.27],[0.0966],1,"n")
      CH2 LL 0.0961:5.25 120 zpk([5.25],[0.0961],1,"n")
      CH3 UR 0.0963:5.26 120 zpk([5.26],[0.0963],1,"n")
      CH4 LR 0.097:5.3 120 zpk([5.3],[0.097],1,"n")

The attached plot and machine readable .txt file version of the above table are also found in ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Results/
2025-10-14_UKSatAmp_S1100118_D0901284-v5_fitresults.txt

Per usual, R_TIA_kOhm is not used in the compensation filter -- but after ruling out an adjustment in the zero frequency (by zeroing the phase residual at the lowest few frequency points), Jeff nudged the transimpedance a bit to get the magnitude scale within the ~0.25%, shown in the attached results. Any scaling like this will be accounted for instead with the absolute calibration step, i.e. Side Quest 4 from G2501621, a la what was done for PR3 and SR3 top masses in LHO:86222 and LHO:84531 respectively.

Non-image files attached to this comment
oli.patane@LIGO.ORG - 17:21, Tuesday 14 October 2025 (87479)

Here's the characterization data and fit results for S1100127, assigned to ETMY L2's ULLLURLR OSEMs.

This sat amp is a UK 4CH sat amp, D0900900 / D0901284. The data was taken per methods described in T080062-v3, using the diagrammatic setup shown on PAGE 1 of the Measurement Diagrams from LHO:86807.

The data was processed and fit using ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Scripts/
plotresponse_S1100127_ETMY_L2_ULLLURLR_20250916.m

Explicitly, the fit to the whitening stage zero and pole, the transimpedance feedback resistor, and foton design string are:

Optic  Stage  Serial_Number  Channel_Number  OSEM_Name  Zero_Pole_Hz  R_TIA_kOhm  Foton_Design 
ETMY L2 S1100127 CH1 UL 0.0963:5.26 121.25 zpk([5.26],[0.0963],1,"n")
      CH2 LL 0.0958:5.24 121.25 zpk([5.24],[0.0958],1,"n")
      CH3 UR 0.0952:5.2 121.25 zpk([5.2],[0.0952],1,"n")
      CH4 LR 0.0954:5.21 121.25 zpk([5.21],[0.0954],1,"n")

The attached plot and machine readable .txt file version of the above table are also found in ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Results/
2025-09-16_UKSatAmp_S1100127_D0901284-v5_fitresults.txt

Per usual, R_TIA_kOhm is not used in the compensation filter -- but after ruling out an adjustment in the zero frequency (by zeroing the phase residual at the lowest few frequency points), Jeff nudged the transimpedance a bit to get the magnitude scale within the ~0.25%, shown in the attached results. Any scaling like this will be accounted for instead with the absolute calibration step, i.e. Side Quest 4 from G2501621, a la what was done for PR3 and SR3 top masses in LHO:86222 and LHO:84531 respectively.

Non-image files attached to this comment
filiberto.clara@LIGO.ORG - 11:26, Thursday 23 October 2025 (87685)

ITMY L2 (PUM) Sat Amp S1100148 installed on 10/14/2025. Replaced on 10/16/2024 with S1100080.

https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=87515

oli.patane@LIGO.ORG - 11:42, Friday 24 October 2025 (87723)

Note that the satamp for ETMY L2 has now been swapped back to a S1100137, which has been modified for ECR E2400330

alog: 87722

H1 General
ryan.short@LIGO.ORG - posted 12:51, Tuesday 14 October 2025 (87467)
LVEA Swept Post-Maintenance

After maintenance wrapped up this morning, I swept through the LVEA to prep for observing. I unplugged an unused extension cord near the PSL racks and the scissor lift in the vertex/west bay area. Everything else looked okay.

Jeff also mentioned that he moved an SR785 from the PSL racks into the Biergarten for his work this morning, but it's unplugged (in case someone goes looking for it later).

H1 CDS
david.barker@LIGO.ORG - posted 12:22, Tuesday 14 October 2025 (87465)
Guardian Pending Source File System (GRD-CFC)

I have created an EPICS IOC which reports any Guardian nodes which use source file(s) which have been modified in userapps but have not been loaded into the nodes. On the next restart of such nodes (e.g. guardian reboot) the new code will be automatically loaded, and so this system permits us to load new code in a scheduled and orderly way, for example by the code-author/node-manager during Tuesday maintenance.

This is similar to the front-end filter-module configuration file change (CFC) system, so I've called this GRD-CFC.

The CDS Overview MEDM has a "GRD CFC" button at the bottom showing the GRD-CFC status as GREEN/YELLOW. Pressing this button opens the H1CDS_GUARDIAN_CFC.adl MEDM (attached).

This MEDM has three main areas:

If any nodes are reporting pending changes, you can get pending file details by running the shell command:

guardian_modified_not_loaded

The output from this command provides information on how to list the line differences between pending files and what is running.

Images attached to this report
LHO VE
david.barker@LIGO.ORG - posted 10:14, Tuesday 14 October 2025 (87464)
Tue CP1 Fill

Tue Oct 14 10:08:10 2025 INFO: Fill completed in 8min 7secs

 

Images attached to this report
H1 GRD (CDS)
thomas.shaffer@LIGO.ORG - posted 08:55, Tuesday 14 October 2025 (87463)
h1guardian1 machine rebooted

Rebooted h1guardian1 at 1547UTC so that we could start with fresh fresh and it would become easier to manage any file differences with help from some of Dave's new screens and scripts.

All nodes started up on their own, and Ryan C helped me recover them all back to a maintenance state.

H1 SEI (GRD, ISC)
thomas.shaffer@LIGO.ORG - posted 08:47, Tuesday 14 October 2025 - last comment - 13:23, Tuesday 14 October 2025(87462)
SEI_ENV node testing with High ASC gain testing

I went to test the high gain ASC states I made for SEI_ENV this morning while we were still locked this morning. The good news is that there were no errors in the code and it did exactly what I asked of it. The bad news is that we lost lock while transitioning back to a low gain state. This wasn't a great test though because I had a brain fart and forgot to change the thresholds for the test. The high gains were turned on, then immediately turned back. So I'm not entirely sure if the lock loss was from the transition back, or just the fact that we quickly flipped it back and forth. 

The major change between what SEI_ENV does and what the script the operators use right now is that the sleep timers between engaging/disengaging each loop are almost completly gone. At minimum for the next test it seems that we need some for the return back to low gain, or maybe increased tramps.

On the bright side, it looks like the structure of the node and the code seems to work, just need to tune it a bit. For now I've returned this node back to its normal operation, without the high asc states.

Images attached to this report
Comments related to this report
ryan.crouch@LIGO.ORG - 13:23, Tuesday 14 October 2025 (87470)

It looks like we lost it from a big DHARD_P oscillation and it corresponds to CHARD_P gain increasing back to nominal right as the P filters are reset? I also made plots of the filter bits from Oli's filter history right click tool.

Images attached to this comment
H1 General
matthewrichard.todd@LIGO.ORG - posted 08:42, Tuesday 14 October 2025 - last comment - 16:02, Thursday 30 October 2025(87461)
OMC scans -- 2025-10-14

M. Todd


Today I ran another OMC scan (following last week's instructions alog 87316 and 87342) after the morning lockloss to see if could a better measurement of the hot state overlaps.

I was still limited to about 12 minutes after the lockloss, so we expect some amount of difference in the full hot state.

I've plotted the results on top of last week's scans, in yellow. Analysis of this will follow in a comment.

Images attached to this report
Comments related to this report
matthewrichard.todd@LIGO.ORG - 16:02, Thursday 30 October 2025 (87870)

Adding mode overlap estimates.

Images attached to this comment
H1 CDS
erik.vonreis@LIGO.ORG - posted 08:35, Tuesday 14 October 2025 (87460)
Workstations updated

Workstations were updated and rebooted.  This was an OS packages update.  Conda packages were not updated.

LHO FMCS
eric.otterman@LIGO.ORG - posted 08:07, Tuesday 14 October 2025 (87458)
LVEA Zone 3B temperature control
The second stage heating contactor had burned up, reducing heating capacity. This is why the zone had difficulty maintaining set point on 10/13. I replaced the ruined contactor and checked functionality. 
H1 PEM (PEM, SEI)
corey.gray@LIGO.ORG - posted 14:10, Friday 10 October 2025 - last comment - 13:05, Tuesday 14 October 2025(87415)
H1 & L1 Down Due to M7.6 EQ (+also some high-ish winds)

Another big EQ rolling through.  This one is down near Antartica!  Debated when to transition to "ASC Hi Gn", since R-wave was going to be 45-60min.  But S&P waves triggered EQ Mode + saw a yellow Picket Fence---Clicked on ASC Hi Gn button, but during the transition H1 lost lock.  This might have been too big for ASC Hi Gn regardless, but kinda wished I clicked it earlier.

Winds were peaking just under 40mph around the lockloss as well.

Will be hanging out here for a few hours. 

Now we wait for R-wave which is probably due to arrive around 2135-ish utc.

Images attached to this report
Comments related to this report
ryan.crouch@LIGO.ORG - 13:05, Tuesday 14 October 2025 (87468)

We lost lock ~3 seconds after CHARD_Y filters bits are changed, there's also a big jump in ground motion at the same time, and it was gusting >30mph at the corner station.

Images attached to this comment
Displaying reports 4181-4200 of 89162.Go to page Start 206 207 208 209 210 211 212 213 214 End