Displaying reports 4801-4820 of 89220.Go to page Start 237 238 239 240 241 242 243 244 245 End
Reports until 21:39, Friday 12 September 2025
H1 SEI
sheila.dwyer@LIGO.ORG - posted 21:39, Friday 12 September 2025 (86896)
Big earthquake, suspensions and ISIs tripped, damped and isolated

ops overvoew screenshot attached.  I untripped things but will not try locking tonight. 

While untripping suspensions I noticed that oddly IM2 watchdog rms monitors were just below the trip threshold, while the other IMs were 2-3 orders of magnitude smaller. The second screen shot shows this curious behavoir.  What about IM2 undamped is so different from the other IMs?

Images attached to this report
H1 General (DetChar)
jane.glanzer@LIGO.ORG - posted 20:19, Friday 12 September 2025 (86895)
Glitch rates before/after power outage and ISS loop on/off test

Summary: omicron glitch rate increases after the power outage, and when the ISS loop is turned off

Using omicron, I made some plots of the glitch rates both before/after the power outage, and then again when the ISS loops were turn on/off. The times chosen were based on the detchar request made by Elenna in alog 86878. For the glitches, I used the omicron frequency/snr parameters of 10 < freq < 1000 Hz and 5 < snr < 500. The first slide in the attached pdf is a comparison of before/after the power outage. It's fairly obvous from the summary pages that the glitch rate increased, but I wanted to quantify just how much it changed. Before the power outage, it was around 45 glitches per hour, and after, it jumped up to about 600 glitches per hour. For both periods, it was around 10 hours of low noise I used for the comparison.

I then did a comparison between when the ISS loop was on versus off. I have found that the glitch rate increased when the ISS loop was turned back off, as can be seen in slide 2.  On slide 3, I have summary page plots showing the WFS A YAW error signal, which looks noisier when the ISS loop is off, and the glitchgram below. On slide 4, I made a spectra comparing H1:CALIB_STRAIN_CLEAN during when the ISS loop was off/on, and we can see an increase in noise from ~ 0.06 Hz - 2 Hz, and at slightly higer frequencies of ~ 10 Hz - 40 Hz.

Non-image files attached to this report
LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 18:27, Friday 12 September 2025 (86894)
OPS Midshift Report

IFO is still trying to lock. I was given instructions to lock until PREP_ASC_FOR_FULL_IFO but after an initial alignment, the highest we could get to was CARM_TO_ANALOG. DRMI is just very unstable, even with manual intervention to maximize POP signal width.

IFO will keep trying to lock until PREP_ASC_FOR_FULL_IFO. I will change the request per instructions.

LHO General
ryan.short@LIGO.ORG - posted 17:28, Friday 12 September 2025 (86891)
Ops Day Shift Summary

TITLE: 09/12 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: Been another busy day of troubleshooting following the power outage. There have been many logs entered with things people have looked into and tried (please see those for more information, as it would be impossible for me to summarize all of it here), but the gist is that we have accepted for now the apparent alignment shift through the IMC, even though this shows much higher reflected power, and reduced the amount of light on the IMC REFL WFS to keep them safe. Since then, we have been trying to relock H1 in this new configuration, but this has been so far plagued with challenges; see Elenna's alog for more on that.
LOG:

Start Time System Name Location Lazer_Haz Task Time End
15:41 FAC Randy Hi-bay N Moving boom lift outside 16:41
15:54 ISC Sheila LVEA N Plugging SR785 in for IMC measurement 16:06
16:11 VAC Richard LVEA N Checking vacuum pump 16:18
17:48 PEM TJ LVEA N Check DM by HAM6 18:18
18:44 VAC Gerardo LVEA N Replacing AIP controller on HAM6 19:05
19:42 ISC Camilla Opt Lab N Getting some bolts and power meter 20:15
19:58 ISC Sheila, Elenna LVEA LOCAL Adjusting IOT2L waveplate 20:59
21:01 ISC Elenna LVEA N Check SR785 21:37
21:37 CDS Marc MY N Finding parts 22:37
H1 ISC (IOO, OpsInfo)
elenna.capote@LIGO.ORG - posted 17:15, Friday 12 September 2025 (86893)
Failing to lock- possible issues with ASC

We have been trying to lock the IFO since we reduced the IMC REFL power. DRMI locking has been causing lots of trouble. First time we locked DRMI quickly, but then as the ASC engaged it pulled the buildups away and I couldn't turn off the ASC fast enough before a lockloss occurred. Then, locking DRMI and PRMI starting talking a very long time, 30 minutes or more. Sheila and I tried turning off the DRMI ASC except the beamsplitter. Then, Ryan S touched up the rest of the DRMI alignment by hand. We made it to ENGAGE ASC FOR FULL IFO, but then as the ASC engaged again the POP 18 buildup started dropping, and then we saw large glitches in all the signals- LSC and ASC, then lockloss. We don't know what caused the issues in full IFO ASC, but it seems similar to the DRMI issue- for whatever reason the ASC is not working properly.

We would like to go back to PREP ASC FOR FULL IFO and slowly engage the ASC by hand to figure out what's going wrong. But DRMI locking is still taking 30 minutes or more, and our recent attempt even the beamsplitter ASC didn't work properly. I think it's safe to say we won't be able to lock, let alone observe, for a while. Even if we could solve these ASC issues, we still need to get to laser noise suppression and check various things to ensure the IMC and ISS loops are working properly, we have the right amount of laser power, no significant glitches or degradations, etc.

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:10, Friday 12 September 2025 (86890)
OPS Eve Shift Start

TITLE: 09/12 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 14mph Gusts, 8mph 3min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.23 μm/s
QUICK SUMMARY:

IFO is LOCKING in DRMI

We still don't know excactly what happened and if we fixed it but:

Now dealing with DRMI instability. Hoping to get locked.

LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 16:00, Friday 12 September 2025 (86889)
HAM6, Removed and Replaced The AIP Controller

Removed and replaced the ion pump controller for the annulus system at HAM6.

No issues doing the replacement, but system AIP system continues railed, we wait and we will continue with troubleshooting next week.

LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 15:58, Friday 12 September 2025 (86888)
Attempt to Activate NEG pump 3

(Anna I., Jordan V., Gerardo M.)

Late entry.

Last Tuesday we attempted to "activate" the NEG pump located on one of the top ports of the output mode cleaner tube, but we opted to do a "conditioning" instead, this due to issues encountered with the gauge related to this NEG pump.  Also, what prompted the work on the NEG pump was the "noted" bump on the pressure inside the NEG housing by the gauge, bump on pressure also noted inside the main vacuum envelope, see attachment for pressure at the NEG housing (PT193) and pressure at PT170.

Side note: Two modes of heating for the NEG pump are available, ACTIVATION and CONDITIONING.  The difference between both options is the maximum applied temperature, for "conditioning" the max temperature is 250 oC, where for "conditioning" the max temperature is 550 oC.  The maximum temperature holds for 60 minutes.

We started by making sure that the isolation valve was closed, checked it and it was closed.  We connected a pump cart+can turbo pump to the system and pump down the NEG housing volume, the aux cart dropped down to 5.4x10^-05 torr, ready for "activation".  However, we noted no response from the gauge attached to this volume, PT193 signal remained flat.  So, we aborted the "activation" and instead we ran a "conditioning" on the NEG.  After the controller finished running the program, we allowed the system to cool down, while pumping on it, then the NEG housing was isolated from the active pumping, hoses and can turbo were removed, then system was returned to "nominal status" or no mechanical pumping on it.

Patrick logged in h0vaclx, but system showed the gauge nominal, and the system did not allowed to turn filaments because pressure is high.

Long story short, the gauge is broken.  Next week we'll visit NEG1, and its gauge PT191.

Images attached to this report
H1 SUS
anthony.sanchez@LIGO.ORG - posted 14:56, Friday 12 September 2025 (86887)
Weekly In-Lock SUS Charge Measurement Analysis

ls /opt/rtcds/userapps/release/sus/common/scripts/quad/InLockChargeMeasurements/rec_LHO  -lt | head -n 6
total 295
-rw-r--r-- 1 guardian           controls  160 Sep  9 07:58 ETMX_12_Hz_1441465134.txt
-rw-r--r-- 1 guardian           controls  160 Sep  9 07:50 ETMY_12_Hz_1441464662.txt
-rw-r--r-- 1 guardian           controls  160 Sep  9 07:50 ITMY_15_Hz_1441464646.txt
-rw-r--r-- 1 guardian           controls  160 Sep  9 07:50 ITMX_13_Hz_1441464644.txt
-rw-r--r-- 1 guardian           controls  160 Sep  2 07:58 ETMX_12_Hz_1440860334.txt

In-Lock SUS Charge Measurements did indeed run this Tuesday.

python3 all_single_charge_meas_noplots.py

Cannot calculate beta/beta2 because some measurements failed or have insufficient coherence!
Cannot calculate alpha/gamma because some measurements failed or have insufficient coherence!
Something went wrong with analysis, skipping ITMX_13_Hz_1440859844

 


 

Images attached to this report
H1 General
anthony.sanchez@LIGO.ORG - posted 14:41, Friday 12 September 2025 (86851)
DRMI Histograms

Ive put togther a number of Histograms that can be used for quick glance of locking state performance marks.

Sheila & Elenna wanted some DRMI Stats dating back to Aug 19th .

Images attached to this report
Non-image files attached to this report
H1 IOO
elenna.capote@LIGO.ORG - posted 13:57, Friday 12 September 2025 - last comment - 17:15, Friday 12 September 2025(86884)
Power on IMC REFL reduced

Sheila and I went out to IOT2L. We measured the power before and after the splitter called "IO_MCR_BS1" in this diagram of IOT2L. This is listed as a 50/50 beamsplitter. However, there is no possible way it can be, because we measure about 2.7 mW just before that splitter, and 2.45 mW on the IMC refl path and 0.25 mW on the WFS path. So we think it must be a 90/10.

Sheila then adjusted the have wave plate upstream of this splitter so that the light on IMC refl dropped from 2.4 mW to 1.2 mW., as measured from the IMC refl diode.

Comments related to this report
elenna.capote@LIGO.ORG - 14:22, Friday 12 September 2025 (86885)

We compensated this change by raising the IMC gains by 6 dB in the guardian. I doubled all the IMC WFS input matrix gains, SDF attached.

Images attached to this comment
elenna.capote@LIGO.ORG - 14:33, Friday 12 September 2025 (86886)

SDFed the IMC PZT position that we think we like.

Images attached to this comment
ryan.short@LIGO.ORG - 17:15, Friday 12 September 2025 (86892)

After the waveplate adjustment and updating of gains in Guardian, we took an IMC OLG measurement with the IMC locked at 2W input. The UGF was measured at 35.0 kHz.

Non-image files attached to this comment
H1 ISC (ISC, PSL)
keita.kawabe@LIGO.ORG - posted 12:54, Friday 12 September 2025 (86882)
Alignment change on the PSL table

(In the attached 1 week trend, [-7 day, -2 day] range is before the power outage and [-1day, 0 day] is after the long high power lock post power outage. Ignore [-2 day, -1 day] because the ISS 2nd loop was messing with the AOM during that time.)

ISS QPD (top right) shows a clearly measurable shift in the alignment mostly in DX (YAW). The QPD is downstream of the PMC, the calibration is supposed to be in mm so nominally it's just 5.4 um but there's a focusing lens in front of it and unfortunately I don't know the focal length nor the distance between the lens and the QPD for now, so the only thing I can say is that the alignment changed downstream of PMC in YAW.

BEA (Bull's Eye Sensor, top left) also shows an alignment shift upstream of PMC. Input matrix of this one is funny, don't read too much into the magnitude of the change. I'm not even sure if it was mostly in PIT or in YAW. (The beam size,  2nd from the top on the left column, also shows a change but I won't trust that because that output is supposed to change when there's an alignment change.)

Images attached to this report
H1 IOO
sheila.dwyer@LIGO.ORG - posted 12:53, Friday 12 September 2025 (86881)
IMC visibility not degrading further today

In our first long lock after the power outage, ISS second loop increased the input power to the IMC by 0.1 W/ hour for 10 hours, MC2 trans was stable, and IMC refl DC increased by 1.7 (mW) per hour (first screenshot)

Last night we left the IMC at 2W, and saw no further degredation. (second screenshot).

Now we increased the power to 60W for an hour and see no further degredation after the transient while the ASC was moving and maybe there was a thermal transient.  (third screenshot)

Images attached to this report
H1 ISC
camilla.compton@LIGO.ORG - posted 12:14, Friday 12 September 2025 - last comment - 12:55, Friday 12 September 2025(86880)
Power on IMC REFL RF PD has increased, plan to decrease it so PD continues to work well

Daniel suggested that as the power has increased on the IMC REFL PD (IOT2L D1300357) by a factor of around 3, was 19mW at 60W in, now 60mW at 60Win, we should reduce the power on this diode as it doesn't work well with high powers. H1:IMC-REFL_DC_OUT16

At 2W input, it was 0.73mW, is now 2mW. Aim for a factor of 2 reduction (to make it simple to reduce electronics gains).

Aim to reduce power on IMC REFL to 1mW using IOT2L waveplate when there is 2W incident on IMC.

Comments related to this report
camilla.compton@LIGO.ORG - 12:55, Friday 12 September 2025 (86883)

Decided we should do this with the IMC OFFLINE. Ryan S put 0.1W into the IMC with the PSL waveplate. This gives 2.37mW on H1:IMC-REFL_DC_OUT16.

Aim to reduce this by a factor of 2 to 1.18mW.

H1 IOO
elenna.capote@LIGO.ORG - posted 11:44, Friday 12 September 2025 (86879)
Change in IMC visibility

A quick calculation of the IMC visibility:

Before power outage:

IMC refl when offline = 46.9

IMC refl when online at 2 W = 0.815

1 - 0.815/46.9 = 0.982

After power outage:

IMC refl when offline = 46.5

IMC refl when online at 2 W = 2.02

1 - 2.02/46.5 = 0.965

So we think we have lost 2.6% of the visibility

H1 DetChar (DetChar, DetChar-Request)
elenna.capote@LIGO.ORG - posted 11:32, Friday 12 September 2025 - last comment - 10:20, Monday 15 September 2025(86878)
Detchar request- help understanding our IMC-related glitches.

I posted the following message in the Detchar-LHO mattermost channel:

Hey detchar! We could use a hand with some analysis on the presence and character of the glitches we have been seeing since our power outage Wednesday. They were first reported here: https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=86848 We think these glitches are related to some change in the input mode cleaner since the power outage, and we are doing various tests like changing alignment and power, engaging or disengaging various controls loops, etc. We would like to know if the glitches change from these tests.

We were in observing from roughly GPS time 1441604501 to 1441641835 after the power outage, with these glitches and broadband excess noise from jitter present. The previous observing period from roughly GPS 1441529876 to 1441566016 was before the power outage and these glitches and broadband noise were not present, so it should provide a good reference time if needed.

After the power outage, we turned off the intensity stabilization loop (ISS) to see if that was contributing to the glitches. From 1441642051 to 1441644851, the ISS was ON. Then, from 1441645025 to 1441647602 the ISS was OFF.

Starting from 1441658688, we decided to leave the input mode cleaner (IMC) locked with 2 W input power and no ISS loop engaged. Then, starting at 1441735428, we increased the power to the IMC from 2 W to 60 W, and engaged the ISS. This is where we are sitting now. Since the interferometer is has been unlocked since yesterday, I think the best witness channels out of lock will be the IMC channels themselves, like the IMC wavefront sensors (WFS), which Derek reports are a witness for the glitches in the alog I linked above.

Comments related to this report
elenna.capote@LIGO.ORG - 10:20, Monday 15 September 2025 (86927)

To add to this investigation:

We attenuated the power on IMC refl, as reported in alog 86884. We have not gone back to 60 W since, but it would be interesting to know if a) there was glitches in the IMC channels at 2W before the attenuation, and b) if there were glitches at 2 W after the attenuation. We can also take the input power to 60 W without locking to check if the glitches are still present.

Displaying reports 4801-4820 of 89220.Go to page Start 237 238 239 240 241 242 243 244 245 End