Displaying reports 5401-5420 of 83944.Go to page Start 267 268 269 270 271 272 273 274 275 End
Reports until 16:55, Saturday 26 October 2024
H1 General
oli.patane@LIGO.ORG - posted 16:55, Saturday 26 October 2024 (80889)
Not-Ops Day End

Only partially an operator today but I still wanted to put in the info from the reservation system today. NPRO work will continue tomorrow.                       

Start Time System Name Location Lazer_Haz Task Time End
16:20 PSL Jason, RyanS PSL Encl y(local) NPRO work 19:48
20:41 PSL Jason, RyanS PSL Encl y(local) NPRO work 22:31
21:01 FIT Neil YARM, XARM n Running a lot 22:12
LHO VE
david.barker@LIGO.ORG - posted 10:20, Saturday 26 October 2024 (80888)
Sat CP1 fill

Sat Oct 26 10:10:15 2024 INFO: Fill completed in 10min 11secs

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 08:44, Saturday 26 October 2024 (80887)
VACSTAT BSC3 sensor glitch, false positive

03:51 Sat 26oct2024 PDT: VACSTAT BSC3 PT132_MPD2 glitch. This is another sensor glitch, delta-P = 1.8e-08 Torr square-wave 2 seconds in width.

As before it is the delta-P which trips (180% of trip value) and not the dP/dt (50% of trip value).

I've reset VACSTAT.

Images attached to this report
H1 General (CAL)
anthony.sanchez@LIGO.ORG - posted 22:12, Friday 25 October 2024 (80886)
PCAL End Y End Station Measurement


TITLE: 10/26 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR:  Ryan S
SHIFT SUMMARY:

PSL is still down, PSL team will be in tomorrow to continue their work. 
I just worked on PCAL measurements for Oct.



PCAL:
Neil and I followed the instructions found on Procedure and Log T1500062 to get an End Y ES measurement done.
Beam Spots Looked great: Beam Spot

The Png files for Martel measurement , WS@TX , WS@RX , WS@ RX with Both Beams at the same time all look fine with out any transients of large spikes.

Analysis of ES data:
Anthony.sanchez@cdsws25: python3 generate_measurement_data.py --WS "PS4" --date "2024-10-25"
Reading in config file from python file in scripts
../../../Common/O4PSparams.yaml
PS4 rho, kappa, u_rel on 2024-10-25 corrected to ES temperature 299.7 K :
-4.710029781861174 -0.0002694340454223 4.653616030093759e-05
Copying the scripts into tD directory...
Connected to nds.ligo-wa.caltech.edu
martel run
reading data at start_time:  1413925750
reading data at start_time:  1413926150
reading data at start_time:  1413926530
reading data at start_time:  1413927000
reading data at start_time:  1413927400
reading data at start_time:  1413927750
reading data at start_time:  1413928050
reading data at start_time:  1413928750
reading data at start_time:  1413929200
Ratios: -0.5343062568395852 -0.5430208346109687
writing nds2 data to files
finishing writing
Background Values:
bg1 =        18.462896; Background of TX when WS is at TX
bg2 =        4.560107; Background of WS when WS is at TX
bg3 =        18.342034; Background of TX when WS is at RX
bg4 =        4.550359; Background of WS when WS is at RX
bg5 =        18.459919; Background of TX
bg6 =        -0.112689; Background of RX

The uncertainty reported below are Relative Standard Deviation in percent

Intermediate Ratios
RatioWS_TX_it      = -0.534306;
RatioWS_TX_ot      = -0.543021;
RatioWS_TX_ir      = -0.527076;
RatioWS_TX_or      = -0.534647;
RatioWS_TX_it_unc  = 0.057219;
RatioWS_TX_ot_unc  = 0.053201;
RatioWS_TX_ir_unc  = 0.057906;
RatioWS_TX_or_unc  = 0.061871;
Optical Efficiency
OE_Inner_beam                      = 0.986371;
OE_Outer_beam                      = 0.984424;
Weighted_Optical_Efficiency        = 0.985397;

OE_Inner_beam_unc                  = 0.044054;
OE_Outer_beam_unc                  = 0.045775;
Weighted_Optical_Efficiency_unc    = 0.063530;

Martel Voltage fit:
Gradient      = 1637.918309;
Intercept     = 0.377773;


 Power Imbalance = 0.983952;

Endstation Power sensors to WS ratios::
Ratio_WS_TX                        = -0.928223;
Ratio_WS_RX                        = -1.383682;

Ratio_WS_TX_unc                    = 0.045315;
Ratio_WS_RX_unc                    = 0.040949;

=============================================================
============= Values for Force Coefficients =================
=============================================================

Key Pcal Values :
GS           =      -5.135100; Gold Standard Value in (V/W)             
WS           =      -4.710030; Working Standard Value             

costheta     =      0.988362; Angle of incidence
c            =      299792458.000000; Speed of Light
             
End Station Values :
TXWS         =        -0.928223; Tx to WS Rel responsivity (V/V)
sigma_TXWS   =        0.000421; Uncertainity of Tx to WS Rel responsivity (V/V)
RXWS         =        -1.383682; Rx to WS Rel responsivity (V/V)
sigma_RXWS   =        0.000567; Uncertainity of Rx to WS Rel responsivity (V/V)

e            =        0.985397; Optical Efficiency
sigma_e      =        0.000626; Uncertainity in Optical Efficiency

Martel Voltage fit :
Martel_gradient         =        1637.918309; Martel to output channel (C/V)
Martel_intercept   =        0.377773; Intercept of fit of     Martel to output (C/V)

Power Loss Apportion :
beta          =        0.998844; Ratio between input and output (Beta)  
E_T          =        0.992098; TX Optical efficiency
sigma_E_T          =        0.000315; Uncertainity in TX Optical efficiency
E_R          =        0.993246; RX Optical Efficiency
sigma_E_R          =        0.000316; Uncertainity in RX Optical efficiency

Force Coefficients :
FC_TxPD          =        9.135057e-13; TxPD Force Coefficient
FC_RxPD          =        6.218936e-13; RxPD Force Coefficient
sigma_FC_TxPD          =        5.086596e-16; TxPD Force Coefficient
sigma_FC_RxPD          =        3.245715e-16; RxPD Force Coefficient
data written to ../../measurements/LHO_EndY/tD20241025/

EY ES Trends found here:
../../measurements/LHO_EndY/tD20241025/


PS4_PS5 Lab measurements
There was also Lab measurements to pair with this:
https://git.ligo.org/Calibration/pcal/-/tree/master/O4/lab/measurements/t20241025_183704_PS4_PS5_FB?ref_type=heads
https://git.ligo.org/Calibration/pcal/-/tree/master/O4/lab/measurements/t20241025_200318_PS4_PS5_BF?ref_type=heads

I checked out these measurements, added them to a trend to see where they fall next to our previous lab measurements , and used them to run the analysis of the ES data with the Latest PS4/PS5 measurments. 
Lab Trends ( Found Here):

PS4PS5_rho_trends
PS4PS5_background_trends.
PS4PS5_alpha_trends.

This Adventure has been brought to you by Tony S and Neil D.
 

 

Images attached to this report
Non-image files attached to this report
H1 PSL
jason.oberling@LIGO.ORG - posted 17:29, Friday 25 October 2024 (80885)
PSL NPRO Swap Day 4 (WP12155)

J. Oberling, R. Short

We continued on from yesterday.  We started by rough aligning our beam through Amp1 in preparation for beam propagation measurements to assess how well we installed our mode matching solution.  We had done a rough alignment previously so expected this to go quick, but it was more off than I expected.  We also checked our beam polarization going into FI01 (after WP01) and going into Amp1 (after WP02) using a temporary PBSC as an analyzer.  The beam should be vertically polarized w.r.t. the table top in both locations.  Going into FI01 the beam was definitely as vertically polarized as WP01.  But after WP02 roughly 50% of the beam was in horizontal polarization (~50mW beam, almost 24mW in horizontal polarization).  This is not good and not how we left this after our PSL recover work in March of 2023; wrong polarization through the amplifiers has a large effect on output beam quality (as learned with the O3 70W amplifier).  This immediately sent up red flags for us, referencing our slowly increasing PMC Refl (increasing since March '24, we swapping the PMC in July because of this).  Immediately we suspected something in FI01 was bad/broke/wrong, and could have been for a while (if something in FI01 had been slowly failing and changing the output beam polarization while failing, that would explain the slowly increasing PMC Refl, as changing the beam polarization from vertical through the amps negatively affects their output beam quality).  We have been using the old Faraday isolator from the 35W Front End laser, but we have 2 spare Newport FIs, identical to the one being used between the amplifiers.  Unfortunately we only have one other FI pedestal base, and it puts the FI at a 100mm beam height, not 4".  We looked through all of the spare pedestal bases from the O4 laser upgrade hoping to find one like is used for FI02 (puts the beam height at 4"), but no other spare FI bases were found.  We also measured the throughput of this Faraday at ~85%, which is lower than the ~93% we had at install.  Something here isn't right.

While checking the FI mount situation out, the alignment situation was bugging me so we took another look.  Checking back through our alignment again we noticed it was off on our alignment iris in front of L02.  So L21 and the EOM were removed and alignment checked again.  The alignment was fine on our first iris but a little off on our second.  M02 was tweaked to fix this, then the EOM installed and its alignment tweaked.  At a point where the EOM alignment looked good on our iris near L02 we decided to check power in and power out, and found we were losing ~6mW through the EOM (this is at a lower alignment power of ~74mW).  We put the power meter at the output of the EOM and adjusted the EOM alignment until the power out of it was maxed; best we could do was ~70mW out with 74mW in.  At this point we looked at the iris near L02 and the beam was a tiny bit high but for the most part looked OK, so we moved on.  L21 was reinstalled and its alignment tweaked.  Now to deal with the Faraday, but first lunch.

After lunch we swapped the Faraday with one of the Newport spares.  Since the pedestal base was a little too short we used a couple of shims under the Faraday to get it at the correct height.  Without making any adjustments to the Faraday we checked the beam on our temporary PBSC, still installed after WP02, and found almost no beam in transmission.  With no changes to the waveplates or tweaking of the Faraday the beam was now much better vertically polarized, lending credence to the theory that something had finally failed in the older Faraday we'd been using (we'll see if this was the source of our PMC Refl issue once we have the PMC up and running again).  We tweaked the angle of the input PBSC on the Faraday to minmize the rejected beam; lowest we could get was 0.40mW.  We then flipped it around and tweaked the output PBSC to minimize the transmitted beam, lowest we could get here was ~17µW; we saw ~11µW once, but we were unable to maintain this while clamping the output PBSC.  Since we found this at ~55 µW we called it a win and moved on.  The Faraday was flipped once again and we began setting up for beam propagation measurements.

These measurements are done with a leakage beam through M03, so we installed a rail (we have blocks in place to make this easy) and set up the WinCam beam profiler.  We then increased the power back to ~1.8W by rotating WP14.  After a little bit figuring out the basics of Varun's script, which we haven't ran since 2023, we were able to take one measurement before we called it for the day:

Our target is 165µm @ 1794.0mm, so we have a little work to do here.  We called it here for the day and will continue with mode matching tweaks and Amp1 recovery tomorrow.

H1 General (Laser Transition, VE)
ryan.crouch@LIGO.ORG - posted 16:35, Friday 25 October 2024 (80875)
OPS Friday day shift summary

TITLE: 10/25 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR: Tony
SHIFT SUMMARY: NPRO swap continues...
LOG:                                                                                                                                                                                                                                                                                                                                                               

Start Time System Name Location Lazer_Haz Task Time End
15:10 SAF LVEA LVEA N LVEA is LASER SAFE 16:34
15:30 TCS TJ LVEA N Looking for TCS pipe fittings 15:53
15:49 PSL RyanS, Jason PSL encl Y NPRO work, camera check 19:07
16:28 OPS Oli LVEA N->Y LAZER HAZARD transition 16:31
16:34 SAF LVEA LVEA Y LVEA is LASER HAZRD 15:14
16:50 SQZ Vicky, Sheila LVEA Y SQZT0 work 18:56
18:17 TCS Camilla, TJ Mech rm, LVEA Y Drain CO2Y chiller 19:20
18:21 SUS Rahul Optics lab N Look for HTTS parts 18:34
18:21 FAC Mitch LVEA Y East bay inventory 18:34
20:01 CAL Tony, Neil PCAL lab Y PCAL measurement prep 20:07
20:03 TCS TJ, Camilla, Brice Mech room N CO2 laser swap 21:00
20:07 CAL Tony, Neil EndY Y PCAL measurement 22:18
20:30 SQZ Sheila, Vicky LVEA Y SQZT0 work 22:56
20:45 PSL Jason, RyanS PSL laser room Y NPRO swap 23:34
21:10 TCS Camilla, TJ LVEA Y TCS table work, CO2Y 21:47
21:47 SUS TJ Optics lab N Find TTS 22:03
22:32 CAL Francisco PCAL lab Y Laptop dropoff 22:47
22:33 CAL Tony PCAL lab Y PCAL post 22:55
Images attached to this report
H1 TCS
camilla.compton@LIGO.ORG - posted 15:57, Friday 25 October 2024 (80883)
Borrowed one of the CO2Y ISS PDs

TJ and I marked the position of the in-loop ISS PD ASSY-D1201065-S1400286photo, removed it and placed a beam dump to catch the beam, photo

Cable (labeled H1:TCSY_4 PD_1) was unplugged moved out the way, corresponds to channels H1:TCS-ITMY_CO2_ISS_IN. We will temporarily use this PD in the CHETA experiment at Caltech. 

We haven't used the CO2 ISS since at least O3, still need to understand if we'll need to start suing the ISS again in O5. 

Images attached to this report
H1 TCS
thomas.shaffer@LIGO.ORG - posted 15:45, Friday 25 October 2024 - last comment - 08:11, Monday 28 October 2024(80882)
TCS X&Y Chiller Flush

Camilla C, Brice W, TJ S

Following the procedure written out by Alastair - T1600050 - today we did a full flush of both chiller lines with ~13gal each.

The last time a full flush was done, and not just refills from line leaks or chiller swaps, was back in 2016 (alog30017). This is notably, much longer than the 6mo service interval the manufacturer recommends. Just like back then, after turning off the lasers, power supplies, and AA chassis, we disconnected all electrical and tried to drain the chillers to start. We struggled to get much out of the chiller via the drain pipe, but a trickle would come out of the process input if the ball valve on the back of the chiller is set to a 45deg angle. After the chillers were mostly drained, we tried to wipe the reservoirs to get out any junk that was in there. We then set up a hose with a quick connect and connected it to the process input line and ran it to a bucket below the mezzanine to avoid carrying large quantities of water down those stairs (see attachment 1). The process output was hooked up to the chiller, then with two people on the mezzanine and one below to watch the bucket and hose, we turned on a chiller and filled the reservoir as the level dropped. We put about 13 gal through the system for each before turning off the chiller, which should be more than each system contains (alog30638).

Seperately, I noticed while we were swapping the TCSY laser that some of the 1/4" tubing connected to the RF driver felt softer than others also connected to it. Turns out, 2 of the 8 connected to it are a different type - Tygon 2001 (softer) vs Tygon2475. According to a data sheet I found, the 2001 has a max working pressure of  30psi compared to the 2475 max at 50psi. We should really think about replaing all of these lines post O4, but I'll need to look into how much pressue these lines actually have.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 08:11, Monday 28 October 2024 (80898)

Checked on the chillers this morning, no extra water was needed, this means we didn't let much air into the system while flushing. Updated T2200289.

H1 CDS
david.barker@LIGO.ORG - posted 11:40, Friday 25 October 2024 - last comment - 17:04, Saturday 26 October 2024(80880)
Slight power glitch Thu 20:38:13 24oct2024 PDT

Jonathan, Dave:

The GC UPS went onto battery power yesterday evening at 20:38 and sent email to sysadmin. The MSR UPS did not send email, it went onto battery power for less than one second. The attached mains_mon trend shows that this glitch was seen in the CS-EBAY, but it was a very slight dip in voltage on two of the phases. Perhaps the glitch was more significant in the GC server area.

Images attached to this report
Comments related to this report
richard.mccarthy@LIGO.ORG - 17:04, Saturday 26 October 2024 (80891)

The GC tolerances are set a little tighter.  We get far more transition on it that the other UPSs.

LHO VE
david.barker@LIGO.ORG - posted 10:22, Friday 25 October 2024 (80879)
Fri CP1 Fill

Fri Oct 25 10:08:35 2024 INFO: Fill completed in 8min 32secs

Images attached to this report
H1 TCS
camilla.compton@LIGO.ORG - posted 09:41, Friday 25 October 2024 - last comment - 10:42, Friday 25 October 2024(80873)
CO2Y Power Control Rotation Stage Calibrated after Laser Swap

After we swapped CO2Y in 80812. We used Ryan's updated Rotation Stage calibration code, now saved as /opt/rtcds/userapps/release/tcs/h1/scripts/RS_calibration/CalibRotStage.py
to calibrate the CO2Y rotation stage. I added another argument so we can use the same code and specify --optic ITMX or ITMY. Updated instructions in the README.txt

Current fitting coefficients: 4.16, 1.99, 59.58, 0.0
New fitting coefficients: 6.5377, 1.9908, 60.5383, 0.0179

Accepted in sdf. Requested using power control for 1.7W, got 1.71W output. Then tested with TCS_ITMY_CO2_PWR guardian (includes bootstrapping) and got 1.71W too. Great.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 10:42, Friday 25 October 2024 (80876)

I checked CO2X by using power control request for 1.7W, got 1.65W output. CO2_PWR guardian bootstrapping has been fixing this to ~1.7W. Re-calibrated to make it more accurate:

Current fitting coefficients: 8.9 1.99 36.41 0.0
New fitting coefficients: 9.0022 1.9905 36.8446 0.017

Plots and accepted sdf's attached. Requested using power control for 1.7W, got 1.72W output. Then tested with CO2_PWR guardian (includes bootstrapping) and got 1.72W too.

Images attached to this comment
H1 General
ryan.crouch@LIGO.ORG - posted 07:34, Friday 25 October 2024 - last comment - 13:20, Friday 25 October 2024(80871)
OPS Friday DAY shift start

TITLE: 10/25 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
    SEI_ENV state: SEISMON_ALERT
    Wind: 11mph Gusts, 9mph 3min avg
    Primary useism: 0.09 μm/s
    Secondary useism: 0.25 μm/s
QUICK SUMMARY:

Comments related to this report
david.barker@LIGO.ORG - 08:42, Friday 25 October 2024 (80872)

h1pslcam1 stopped giving an image sometime between 18:00 and 19:00 Tue 22oct2024. The camera cannot be pinged.

A reminder of this camera's image is attached.

Images attached to this comment
david.barker@LIGO.ORG - 09:51, Friday 25 October 2024 (80878)

PSL Team have fixed the camera.

ryan.crouch@LIGO.ORG - 13:20, Friday 25 October 2024 (80881)

The camera looks dead again, PSL team said they didn't actually do anything when they checked out the camera earlier.

H1 CDS
david.barker@LIGO.ORG - posted 10:29, Thursday 24 October 2024 - last comment - 08:44, Friday 25 October 2024(80861)
FMCSSTAT alert due to LVEA zone4 temp increase

FMCSSTAT is currently RED on the CDS Overview due to a sharp increase in LVEA Zone4 temperature (around HAM6) at 08:59 PDT. TJ confirmed this was due to powering up a clean room.

A reminder that the FMCSSTAT button on the CDS Overview stays RED for up to 2 hours after the alert to give everyone time to see it.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 16:29, Thursday 24 October 2024 (80865)

Megaclean room was turned off ~4:15pm. 

david.barker@LIGO.ORG - 08:44, Friday 25 October 2024 (80874)

FMCS STAT correctly reported the cool down of zone4

Images attached to this comment
H1 SEI (CSWG, ISC, SEI, SUS, SYS)
jeffrey.kissel@LIGO.ORG - posted 13:04, Tuesday 15 October 2024 - last comment - 16:07, Monday 28 October 2024(80683)
Measurements of HAM2ISI to/from SUS PR3 Sus Point and M1 Stages Successful, But Incomplete
J. Kissel
WP 12140

I've completed 6 SUS + 4 ISI = 10 of 12 total DOF excitations that I wanted to drive before I ran out of time this morning. Each drive was "successful" in that I was able to get plenty of coherence between the 4 DOFs of ISI drive and SUS response, and some coherence between 6 SUS drive DOFs and ISI response. As expected, the bulk of the time was spent tuning the ISI excitations. I might have time to "finish" the data set and get the last two missing DOFs, but I was at least able to get both directions of LPY to LPY transfer functions, which are definitely juicy enough to get the analysis team started.

Measurement environmental/configuration differences of the HAM2 ISI from how they are nominally in observing:
    - PR3 M1 DAMP local damping loop gains are at -0.2, where they are nominally at -1.0. (The point of the test.)
    - CPS DIFF is OFF. (needed to do so for maintenance day)
    - Coil Driver z:p = 1:10 Hz analog low-pass (and digital compensation for it) is OFF. (need to do so to get good SNR on SUS M1 drive without saturating the SUS DACs)

Interesting things to call out that are the same as observing:
    - The PR3 alignment sliders were ON. P = -122 [urad]; Y = 100 [urad]. (Don't *expect* dynamics to change with ON vs. OFF, but we have seen diagonal response change if close an EQ stop. Haven't ever looked, but I wouldn't be surprised of off-diagonal responses change. Also DAC range gets consumed by DC alignment request, which is important for driving transfer functions.)
    - Corner station sensor correction, informed by the Bier Garten "ITMY" T240 on the ground. (the h1oaf0 computer got booted this morning, so we had to re-request the SEI_CS configuration guardian to be in WINDY. The SEI_ENV guardian had been set to LIGHT_MAINTENANCE.)
    - PR3 is NOT under any type of ISC global control; neither L, P, or Y. (global ISC feedback for the PRC's LPY DOFs goes to PRM and PR2.)

There are too many interesting transfer functions to attach, or even to export in the limited amount of time I have. 
So -- I leave it to the LSC team that inspired this test to look at the data, and use as needed.

The data have been committed to the SVN here:
    /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/PR3/SAGM1/Data/
        2024-10-15_1627_H1SUSPR3_M1_WhiteNoise_L_0p02to50Hz.xml
        2024-10-15_1627_H1SUSPR3_M1_WhiteNoise_T_0p02to50Hz.xml
        2024-10-15_1627_H1SUSPR3_M1_WhiteNoise_V_0p02to50Hz.xml
        2024-10-15_1627_H1SUSPR3_M1_WhiteNoise_R_0p02to50Hz.xml
        2024-10-15_1627_H1SUSPR3_M1_WhiteNoise_P_0p02to50Hz.xml
        2024-10-15_1627_H1SUSPR3_M1_WhiteNoise_Y_0p02to50Hz.xml

    /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/PR3/Common/Data
        2024-10-15_1627_H1ISIHAM2_ST1_WhiteNoise_PR3SusPoint_L_0p02to50Hz.xml
        2024-10-15_1627_H1ISIHAM2_ST1_WhiteNoise_PR3SusPoint_T_0p02to50Hz.xml
            [ran out of time for V]
            [ran out of time for R]
        2024-10-15_1627_H1ISIHAM2_ST1_WhiteNoise_PR3SusPoint_P_0p02to50Hz.xml
        2024-10-15_1627_H1ISIHAM2_ST1_WhiteNoise_PR3SusPoint_Y_0p02to50Hz.xml


For the SUS drives templates, I gathered:
     Typical:
     - The top mass, M1, OSEM sensors, in the LTVRPY Euler Basis, calibrated into microns or microradians, [um] or [urad].
         H1:SUS-PR3_M1_DAMP_?_IN1_DQ             [Filtered with the 64x filter, then downsampled to to fs = 256 Hz]
     - The top mass, M1, OSEM sensors, in the T1T2T3LFRTSDD OSEM Sensor/Coil Basis, calibrated into microns, [um].
         H1:SUS-PR3_M1_OSEMINF_??_OUT_DQ         [Filtered with the 64x filter, then downsampled to to fs = 256 Hz]
     - The top mass, M1, OSEM coils' requested drive, in the T1T2T3LFRTSD OSEM Sensor/Coil Basis, in raw (18 bit) DAC counts, [ct_M1SUS18bitDAC].
         H1:SUS-PR3_M1_MASTER_OUT_??_DQ          [Filtered with the 32x filter, then downsampled to to fs = 512 Hz]

     For this set of templates:
     - The bottom mass i.e. optic, M3, OSEM sensors, in the LPY Euler Basis, calibrated into microns or microradians, [um] or [urad].
         H1:SUS-PR3_M3_WIT_?_DQ                  [Filtered with the 64x filter, then downsampled to to fs = 256 Hz]
     - The bottom mass i.e. optic, M3, optical lever, in PIT YAW Euler Basis, calibrated into mircoradians, [urad].
         H1:SUS-PR3_M3_OPLEV_???_OUT_DQ          [Filtered with the 64x filter, then downsampled to to fs = 256 Hz]
     - The ISI's Stage 1 GS13 inertial sensors, projected to the PR3 suspension point LTVRPY Euler basis, calibrated into nanometers or nanoradians, [nm] or [nrad]
         H1:ISI-HAM2_SUSPOINT_PR3_EUL_?_DQ       [Filtered with the 4x filter, then downsampled to to fs = 1024 Hz]
     - The ISI's Stage 1 super sensors, in the ISI's Cartesian XYZRXRYRZ basis, calibrated into nanometers or nanoradians, [nm] or [nrad]
         H1:ISI-HAM2_ISO_*_IN1_DQ                [Filtered with the 2x filter, then downsampled to to fs = 2048 Hz]

Note: The six M1 OSEM sensors in the Euler Basis are set to be the "A" channels, such that you can reconstruct the transfer function between the M1 Euler Basis to all the other response channels in the physical units stated above. As usual the excitation channel for the given drive DOF (in each template, that's H1:SUS-MC3_M1_TEST_?_EXC) is automatically stored, but these channels are in goofy "Euler Basis (18-bit) DAC counts," so tough to turn into physical units.

For the brand new ISI drive templates, I gathered:
     - The ISI's Stage 1 super sensors, in the ISI's Cartesian XYZRXRYRZ basis, calibrated into nanometers or nanoradians, [nm] or [nrad]
         H1:ISI-HAM2_ISO_*_IN1_DQ                [Filtered with the 2x filter, then downsampled to to fs = 2048 Hz]
     - The ISI's Stage 1 GS13 inertial sensors, projected to the PR3 suspension point LTVRPY Euler basis, calibrated into nanometers or nanoradians, [nm] or [nrad]
         H1:ISI-HAM2_SUSPOINT_PR3_EUL_?_DQ       [Filtered with the 4x filter, then downsampled to to fs = 1024 Hz]

     - The top mass, M1, OSEM sensors, in the LTVRPY Euler Basis, calibrated into microns or microradians, [um] or [urad].
         H1:SUS-PR3_M1_DAMP_?_IN1_DQ             [Filtered with the 64x filter, then downsampled to to fs = 256 Hz]
     - The bottom mass i.e. optic, M3, OSEM sensors, in the LPY Euler Basis, calibrated into microns or microradians, [um] or [urad].
         H1:SUS-PR3_M3_WIT_?_DQ                  [Filtered with the 64x filter, then downsampled to to fs = 256 Hz]
     - The bottom mass i.e. optic, M3, optical lever, in PIT YAW Euler Basis, calibrated into mircoradians, [urad].
         H1:SUS-PR3_M3_OPLEV_???_OUT_DQ          [Filtered with the 64x filter, then downsampled to to fs = 256 Hz]
     - The ISI's Stage 1 actuators' requested drive, in the H1H2H3V1V2V3 ISI actuator basis, in raw (16-bit) DAC counts, [ct_ISIST116bitDAC].
         H1:ISI-HAM2_OUTF_??_OUT                 [Didn't realize in time that there are DQ channels H1:ISI-HAM2_MASTER_??_DRIVE_DQ stored at fs = 2048 Hz, or I would have used those.]

Note: Here, I set the number of "A" channels to twelve, such that both the ISI's Cartesian basis and the PR3 Suspoint basis versions of the GS13s can be used as the transfer function reference channel. 
Comments related to this report
jeffrey.kissel@LIGO.ORG - 13:50, Tuesday 15 October 2024 (80688)
OK ok ok. I couldn't resist and it didn't take that long. 

I attach the unit-full transfer functions between the ISI Sus. Point Drive DOFs (L, P, Y, and T) and the Top Mass SUS M1 OSEMs response in L, P, Y.

It's.... a complicated collection of TFs; and this isn't all of them that are relevant!

Just to make the point that Dan DeBra taught Brian Lantz, who taught me, and we're passing down to Edgard Bonilla: *every* DOF matters; the one you ignore is the one that will bite you.
The transverse, T, DOF drive data set demonstrates this point. None of these transverse to LPY couplings nominally exist if we just consider first principles equations of rigid-body motion of an ideal suspension. But alas, the on-resonance coupling from T to L, P, Y ranges from 0.1 ... to 50 [m/m] or [rad/m]. 

I may need to drive the ISI with an entirely different color of excitation to resolve these transfer functions above 5 Hz, where it's perhaps most interesting for DARM, but this is a good start.

The ISI drive templates have been re-committed to the repo with the calibrations of each channel in place. (It was really easy: just multiplying each channel by the appropriate 1e-9 [m/nm] or 1e-6 [m/um] in translation, and similar 1e-9 [rad/nrad] or 1e-6 [rad/urad].)
Images attached to this comment
brian.lantz@LIGO.ORG - 09:50, Wednesday 16 October 2024 (80709)

Thank Jeff!

You were right - this looks much more interesting than I had hoped. We'll run the scripts for the SUS to SUS TFs and put them up here, too.

Transverse to Pitch at 50 rad/m on resonance. Maybe "only" 10 when you turn up the damping to nominal? Ug.

brian.lantz@LIGO.ORG - 16:07, Monday 28 October 2024 (80907)

I've also taken a look at how much the ISI moves when Jeff drives the BOSEMs on the top stage of PR3. The answer is "not very much". I've attached two plots, one for the top mass Yaw drive and the other for the top mass length drive. note - The ISI reponses need to be divided by 1000 - they are showing nm or nrad/drive, while the SUS is showing microns or microradians/drive.

So - the back reaction of the osem drives can be safely ignored for PR3, and probably all the triples, as expected. (maybe not for the TMs, not that it matters right now).

It raises 2 questions

1. How do I divide a line by 1000 in a dtt plot? (I feel so old)
2. Why does the green line (SUSPoint) look so much noiser that the cart-basis blend signals? I would expect these to look nearly identical above about 1/2 Hz, because the blend signal is mostly GS-13. The calibrations look right, so why does the TF to the GS-13 signal look so much worse than the TF to the blend output?

These plots are at {SUS_SVN}/HLTS/H1/PR3/SAGM1/Results/

2024-10-15_length_to_length_plot.pdf
2024-10-15_yaw_to_yaw_plot.pdf

Non-image files attached to this comment
jeffrey.kissel@LIGO.ORG - 10:17, Wednesday 23 October 2024 (80835)
I grabbed the remaining ISI drive degrees of freedom this morning, V and R. The color and strength of the excitation was the same as it was on Oct 15th, where I used the L drive excitation params for V, and the P drive excitation params for R.

PR3 damping loops gains were at -0.2 again,
Sensor correction is ON,
CPS DIFF is OFF.
PR3 alignment offsets are ON.

For these two data sets, the PR3 top mass coil driver low pass was still ON (unlike the Oct 15th data), but with the damping loop gains at -0.2, there's no danger of saturation at all, and the low pass filter's response is well compensated, so it has no impact on any of the ISI excitation transfer functions to SUS-PR3_M1_DAMP_?_IN1_DQ response channels. It's only really important to have the LP filter OFF when driving the SUS.

There was the remnants of an earthquake happening, but the excitations were loud enough that we still got coherence above at least 0.05 Hz.

Just for consistency's sake of having a complete data set, I saved the files with virtually the same file name:
     /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/PR3/Common/Data/
         2024-10-15_1627_H1ISIHAM2_ST1_WhiteNoise_PR3SusPoint_L_0p02to50Hz.xml
         2024-10-15_1627_H1ISIHAM2_ST1_WhiteNoise_PR3SusPoint_T_0p02to50Hz.xml
         2024-10-15_1627_H1ISIHAM2_ST1_WhiteNoise_PR3SusPoint_V_0p02to50Hz.xml   # New as of Oct 23
         2024-10-15_1627_H1ISIHAM2_ST1_WhiteNoise_PR3SusPoint_R_0p02to50Hz.xml   # New as of Oct 23
         2024-10-15_1627_H1ISIHAM2_ST1_WhiteNoise_PR3SusPoint_P_0p02to50Hz.xml
         2024-10-15_1627_H1ISIHAM2_ST1_WhiteNoise_PR3SusPoint_Y_0p02to50Hz.xml
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 12:56, Wednesday 23 October 2024 (80847)
Today I also gathered another round of all six DOFs of ISI excitation, but this time changing the color of the excitation to get more coherence between 1 to 20 Hz -- since this is where the OSEM noise matters the most for the IFO. In the end, the future fitter may have to end up combining the two data sets to get the best estimate of the plant.

In the same folder, you'll find 
    /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/PR3/Common/Data
        2024-10-23_1739_H1ISIHAM2_ST1_WhiteNoise_PR3SusPoint_L_0p02to50Hz.xml
        2024-10-23_1739_H1ISIHAM2_ST1_WhiteNoise_PR3SusPoint_P_0p02to50Hz.xml
        2024-10-23_1739_H1ISIHAM2_ST1_WhiteNoise_PR3SusPoint_R_0p02to50Hz.xml
        2024-10-23_1739_H1ISIHAM2_ST1_WhiteNoise_PR3SusPoint_T_0p02to50Hz.xml
        2024-10-23_1739_H1ISIHAM2_ST1_WhiteNoise_PR3SusPoint_V_0p02to50Hz.xml
        2024-10-23_1739_H1ISIHAM2_ST1_WhiteNoise_PR3SusPoint_Y_0p02to50Hz.xml

Happy fitting!
brian.lantz@LIGO.ORG - 16:00, Thursday 24 October 2024 (80863)

Here is the set of plots generated by {SUSsvn}/Common/MatlabTools/plotHLTS_dtttfs_M1 for the data Jeff collected on Oct 15.
(see above, the data set is in 6 text file with names like 2024-10-15_1627_H1SUSPR3_M1_WhiteNoise_L_0p02to50Hz_tf.txt (L, P, Y, etc)

These are funny looking because the damping loops are only running at 1/5 of the normal gain. This gives higher-Q peaks and less OSEM noise coupling. This is done as part of an exercise to run the detector with a combination of real OSEM signals (ie the ones here) PLUS model-based OSEM estimators. I've set the script to show all the cross terms, and these are clearly present. It remains to be seen how much the various cross terms will matter. This is the data we will use to help answer that question.

I've also attached a slimmed-down version of the cross-coupling plots which just shows the coupling to yaw. These are the same plots as above with some of the lines removed so that I can see what is happening to yaw more easily. In each plot the red is the measured cross-coupling from dof-drive to Yaw-response. For reference, these also include the light-blue yaw-to-yaw and the grey dof-to-dof measurements.

These plots and the .mat file are in the SUS SVN at {SUS_SVN}/HLTS/H1/PR3/SAGM1/Results/

2024-10-15_1627_H1SUSPR3_M1.mat
2024-10-15_1627_H1SUSPR3_TFs_lightdamping_yawonly.pdf
2024-10-15_1627_H1SUSPR4_M1_ALL_TFs_lightdamping.pdf

Non-image files attached to this comment
brian.lantz@LIGO.ORG - 20:40, Thursday 24 October 2024 (80870)

On a side note, the ISI to ISI TFs are not unity between 0.1 and 1 Hz. I think they should be. This is a drive from the blended input of the control loop (well, several, because it's in the EUL basis) to the signal seen on the GS-13, in the same EUL basis, converted to displacement (so it will roll off below 30 mHz, because the the realtime calibration of the GS-13s in displacement rolls off, and it has a bump at 30 Hz because this is really the complementary sensitivity, and that has a bump because of the servo bump)

But it should be really close to 1 from 0.1 to 3 Hz. The rotational DOFs (right side, red line) look pretty good, but the translations (L, V, T) all show a similar non-unity response. Jim and Brian should discuss. They look similar to each other, so maybe it's a blend which isn't quite complementary?

Non-image files attached to this comment
brian.lantz@LIGO.ORG - 16:56, Saturday 26 October 2024 (80890)

I've plotted the TFs from the SUSpoint drive to the M1 EUL basis TFs. Note that in the plots, I've adjusted the on-diagonal model plots to be -1 + model. The model is the INERTIAL motion of the top stage, the measured TFs all show the RELATIVE motion between the ISI and top stage. So you want to model Top/ISI - ISI/ISI or -1 + model. This is only true for the on-diagonal TFs.

The code to do this lives in {SUSsvn}/HLTS/Common/MatlabTools/plotHLTS_ISI_dtttfs_M1.m

I've attached a big set of pdfs. The cross couplings look not-so-great. See the last 5 plots for the cross-couplings of dof->Yaw. in particular, L->Y is about the same as Y->Y. (pg 22)

The pdfs and the .mat file have been committed to the SVN at

{SUSsvn}/HLTS/H1/PR3/SAGM1/Results/
  2024-10-15_1627_H1SUSPR3_M1_SUSpointDrive.mat
  2024-10-15_1627_H1SUSPR3_M1_ALL_TFs_lightdamping_SUSpointDrive.pdf

(Also, see in the previous comments, there was a file which I named ...PR4...  this is now corrected to ...PR3... )

Non-image files attached to this comment
Displaying reports 5401-5420 of 83944.Go to page Start 267 268 269 270 271 272 273 274 275 End