Today we have a different type of interesting seismic time, the low frequency ground motion due to the earth quake has subsided, but we still have microseism well above the 90th percentile (the wind has also died down). While the microseism is high, it seems like these might be conditions we want to be able to ride out in the long run. ETMX and ITMX are both isolated with Tcrappy (no sensor correction), both have pitch fluctuations of about 0.3urad, but yaw fluctuations of more than 1 urad. Right now it is UTC 1:28.
A screenshot of the ground motion and Op Levs are attached, the .xml file which also includes SEI sensors is available here
Is this ground motion just too much for us to ride out, or is there a configuration for the ISIs that would be better under these conditions?
Though they haven't been confirmed to work well under these conditions, you should try switching to the "Start" filters (which have a high blend frequency) on ST2, and switching on some modest ST1 to ST2 sensor correction. You lose performance at 1 [Hz] but improve microseism by a factor of 10ish. You can see the variation in performance from LHO aLOG 10728, specifically, the attachment. Note, we can also try the T750 [mHz] blend filters on ST1, but I don't have a good aLOG of their performance. My guess is that Seb didn't have time to characterize this configuration. #movetheblendUP
(Jax, Alexa)
Things that went well this weekend:
1. Alignment of components: the components on ISCTEY are largely in good alignment, with one exception - we ran out of time to align PD4 (faraday rejection/green laser power).
2. Fiber polarization is adjusted fairly well.
3. Beam scan of green input beam was taken for a baseline measurement for possible beam quality issues in the future. This scan was taken after PZT2 (wanted more points but getting the beam to nanoscan height was being difficult with what I had at the end station).
Things that did not go well this weekend:
1. PZT mirrors: the PZT mirrors move, but not as desired - there's some p/y coupling, especially in PZT2. The readbacks look questionable as well. Needs follow-up.
2. Acquisition of PLL beatnote: despite some pretty exhaustive alignment to the BBPD, there's no appreciable beatnote. Lots of alignment tweaks and laser temperature adjustments only led to us finding something weak on the laser at 750kHz.
Our working theory was that we're not getting enough power out of the fiber.
To the table: 75 uW
Onto the table: 65 uW
After PBS: 45 uW
After the splitter that brings it to the main path: 22 uW
This may or may not be enough power. Sheila suggested we might be saturating the PD with the laser light, but we're planning on taking a closer look at possible causes tomorrow.
In summary, lots of work got done, but there's lots left.
I redid the baffle PD alingment today:
Baflle PD 1: 203.4 Pit -236 YAW
Baffel PD 4: 272.4 PIT -297.1 YAW
Aligned: 237.9 PIT -266.5 YAW
This is only a 3 urad change in Pitch from the save values, 1 urad in yaw. I saved these new positions.
I also wanted to see if we can use the ITMX Gig E camera instad of the baffle PDs for TMS pointing. I unlocked the IMC and misalinged MC2, and mislianged the PZTs on ISCEX. In this situation there should be no IR or Green on ITMX, but I still see some spots on the camera, maybe these are from an OPLEV? The pixel sum is between 900 and 1600. (exposure is set to 100000). At least in single shot, it doesn't seem like we can use the camera to replace the baffle PDs.
I moved PR3 by about 1 urad in TAW and half a urad in pitch to center the beam on the ISCT1 camera.
Then an earth quake hit (maybe 6.7 in Chile). The 0.03-0.1Hz seismic band has been above the uper limit of the FOM chart for about an hour.
(Jax, Alexa)
Yesterday we observed that the transmitted light from the fiber was entirely the wrong polarization. This morning, we started out by changing the settings on the MPC.
Settings for X-bound fiber: +18.75 -60.00 -4.50
Initial Y-bound settings: +5.70 -25.35 -56.85
The PD on the fiber monitor path is likely misaligned so we had to optimize based on minimizing power on the fiber polarization PD. Given that criteria, we started with the X-end settings and adjusted to a nominal condition.
Y-bound settings: +18.6 -61.35 -42.30
No guarantees we won't be commenting on this entry later with updated settings.
I haven't caught up on logs now but I'll report what I've found.
Pretty easy--All HEPIs are isolating with Position loops.
All BSC ISIs are Isolating at Lvl3 with TCrappy Blends; HAM 2 & 3 are running Lvl3 controllers with 01-28 blends. HAM4 is running a Fake Lvl3 with 250 Blend.
Summary: moving both red and green beams to a single periscope seems to have greatly reduced the periscope contribution to the RMS. In HIFO-Y the contribution was about 7 Hz while in HIFO-X, after the move, it is roughly 0.5 Hz. About half of the current HIFO-X periscope peak contribution comes from the periscope on ISCT1 (65-75, 95-105 Hz in the spectrum) with the rest coming from the periscope inside HAM1 (the 68 Hz sharp peak). The forest of peaks between 250 and 700 Hz come from optic supports along the beam paths on ISCT1.
I investigated vibrational noise in the current HIFO-X spectrum. Figure 1 shows coherence between H1:LSC-REFL_SERVO_SLOW_OUT_DQ and the environmental sensors with the most coherence, accelerometers on the ISCTEX table at EX, and the PSL and ISCT1 periscopes at the corner station. Vibration is the source of most of the signal 60 - 900 Hz, and may also become dominant at lower frequencies as other noise sources are reduced. Of course vibrational levels in the region around 100 Hz are now roughly a factor of two or three above what we hope they will be in science mode.
I tap tested ISCT1 while the arm was locked to confirm that the broad peaks in the HIFO-X spectrum at 65-75 Hz and 95-105 Hz were due to the ISCT1 red/green periscope. They do not closely follow the shape of the periscope peak in the accelerometer on the periscope (Figure 1), probably because the features in the HIFO-X spectrum are produced by differences in periscope motion along the red and green path, not total motion. Tap testing also showed that the forest of peaks between 250 and 700 Hz is mainly due to individual optic supports along the red and green paths on ISCT1.
Tap testing did not excite the sharp 68 Hz peak that sits on top of the ISCT1 periscope peaks. Figure 2 shows that I was instead able to excite it with a frequency-sweeping shaker on a blue cross beam of HAM1. The lower plot in Figure 2 shows that the shaker could not have been exciting HAM2 or ISCT1 enough to produce the peak, supporting the conclusion that the peak is due to motion inside HAM1. A very likely source of the 68 Hz peak is the tall periscope inside HAM1 (shown in Figure 3) used to direct the beams to the red/green periscope on ISCT1. Other optic supports in HAM1 should have much higher frequencies.
Moving the two beams onto a single periscope, suggested by Stefan, seems to have worked very well. In HIFO-Y the red and the green ISCT1 periscopes added about 7 Hz to the HIFO-Y RMS (here). In Shiela’s calibrated H1:LSC-REFLBIAS_OUT spectrum, with the calibration thought to be good to a factor of a couple at this frequency, the 65-75, 95-105 Hz portion of the ISCT1 periscope peak adds about 0.20 Hz to the RMS. The 68 Hz HAM1 periscope peak adds about 0.17 Hz (it added a lot more before the clean room was turned off).
Carefully calibrated spectra for periods with similar ground motion have indicated that the peak from the single periscope in HIFO-X was NOT significantly smaller than the peak from the two periscopes in HIFO-Y. -Robert
Jax and I went to EY to start up the ISCTEY table, and found that there was no fiber power coming to EY. The cable in the MSR from the MPC to EY is double ended and the wrong end was plugged in to the end station. This has now been fixed. I crudely measured the following powers:
Input of MPC @ MSR ~ 300uW
To EY @ MSR ~224uW
Into ISCTEY patch panel ~ 90uW
I made no adjustments to the MPC; the controller is still off.
We mounted the second green Faraday on a 4-axes mount and reworked the Green injection path to make the beam shape less clipped. We needed to go close to the edge of the EOM and Faraday aperture to get the best beam quality.
As for the EOM, the best beam shape was achieved when the beam is very close to the top edge of the output aperture, maybe it was already touching the hole. We backed off the height adjustment screw (closer to the output) of the EOM mount by half turns so there's no apparent clipping but it's still very close. With this backed off position the beam shape was not as good but we called it good anyway as we couldn't do anything about it.
Anyway, since the center of the aperture for Faraday as well as EOM is NOT the best position as far as the beam quality is concerned, Faraday and EOM should be on adjustable mount. The first Faraday is still fixed, and this means that the beam is not horizontal along the beam path through the first Faraday, which is OK but not ideal (e.g. the beam is not completely centered on the first lens).
We still don't know if this new beam path arrangement is any better or worse than before.
We took some beam profile measurements, which Sheila will post later. Quality of the injected beam is better, the beam coming back to WFSA looked better than before, WFSB was worse.
Our measurements from this afternoon are attached...
apperature 1 was horizontal for hese measurements, apperature 2 vertical
PUM P injection to OL Y transfer function, green is old and brown is now. Also shown in blue is the Y to Y transfer function so that you can tell if the coupling is large or small.
The peaks were reduced by 10 to 12dB and I guess this is good enough.
Craig Conley, Doug Cook, Travis Sadecki, Rick Savage Today we used a 1047 nm alignment laser to assess the as-installed alignment of the Pcal periscope optics for the Pcal paths. We didn't yet verify the alignment of the ETM camera view optics because the viewports for those paths have not yet been installed. This will hopefully be completed next week. The alignment looks very good. One mirror on the upper beam path required a slight adjustment, but otherwise everything was well-aligned as found. Note that the first contact has been removed from both sides of both Pcal windows on the A1 adapter (thank you Margot). We transitioned back to Laser Safe. We removed the YLF alignment laser and we are closing the work permit. The four pairs of special 1 micron-only laser glasses are being returned to the LSB Optics Lab. The work permit for this task has been closed (signed off). Thanks to JustinB for all the assistance with the temporary SOP.
Please log excursions to Y end. If you look on OPWS0 you can see if it is still running. It will likely be done fairly early SaturdayAM so you'll mostly be in the clear. Call me-619-3304.
J. Kissel, A. Pele We had a huge wind storm (30 mph average, 50+ mph gusts) this afternoon that was taking down HEPIs and ISI left and right. Moving the blend UP didn't help. We decided to just leaving the ISIs off for a bit just to gather environmental data and watch the storm roll by, since no interferometry could be done. For 1 hour, starting at GPS 1078868350, Mar 14 2014 21:38:54 UTC, For ITMX and ITMY HEPI - isolation level 1, 'pos' blends ISIs - Damping Only QUADs - Damped After an hour or so, HEPI ITMX tripped. As of Mar 15 2014 00:40:00 UTC, all 4 BSC chambers have been left at their believed to be best performance during low-wind times: HEPI - isolation level 1, 'pos' blends ISIs - isolation level 3, 'TCrappy' Blends QUADs - Damped
Got the CPS racks grounded and wired up. Fine tuned the Dial Indicators. Still need to do some cable strain relief but I'm out of hardware and this is not the only place that is needed.
Ready for chamber cleaning to prep for opening.
I ran a few static tests yesterday on ETMY HEPI. Things like linearity & range of motion etc. Attached is a two plot of trends on the HEPI Cartesian basis IPS. X & Y have moved a few ums while Z and Rx & Ry are pretty steady. Rz has rotated a little more now out to 22urads. Again this is good for the alignment now as long as it doesn't go further.
Dave, Stefan We tried a PRX length measurement, but had to conclude that - REFL is swamped with the direct reflection signal - the expected broad bump is not visible. - POP has too much attenuation - he do not see a beat note at all. The interferometer is thus available for the rest of the night.
All actuator sub assemblies have been completed. Time with Jim is required to add these sub assemblies to the ISI. All of the flexure sub assemblies 0-1, and 1-2 have been completed. The granite table has been cleared in preparation for monolithic plates, which were brought over to the staging building this afternoon by Apollo.
Clean-up of RGA is slow at the reduced temperatures used -> RGA is isolated from the BT via (2) series-connected closed 1 1/2" valves
6:20 -> Working at End X – Jodi 7:20-8:10 -> Heading to End Y – Jodi 8:45-9:10 Going to End Y to work on dust monitor – Jeff.B 9:01-11:54 HEPI work on HAM5 - Hugh 9:15-9:30 Dust monitor work by HAM5 (LVEA) – Jeff.B 9:24- Going to End Y – Travis 9:30-10:00 End Y cleaning - Karen 9:35 -> PSL Check List (OK) 10:16-13:39 H2 Laser enclosure work – Gerardo 10:38-11:04 Working on SR3 (LVEA) – Jeff B. 10:43-11:30 Searching for cables at Mid Y – Filiberto 10:45-12:35 Going to End X (cleaning) - Cris 11:20 -> Laser turned ON at End Y – Rick S. 11:30 -> LVEA transitioned to Laser Hazard - Justin 13:20-14:30 Back to HAM 5 – Hugh 13:30- Working at End X – Keita 13:58- Joining Keita at End X – Sheila 14:08- In LVEA working on nitrogen piping - Apollo
Travis, Margot, and Kate
Removed the horizontal 4" wafer from the beamtube (between the purge air port and ACB). The 1" optic that was placed with the wafer couldn't be removed (no PETG containers available), so it was moved to the opposite tube for the time being. When possible, it should be moved back to its original location or removed. A new 1" optic (s/n 1195) was mounted vertically to the QUAD.
Refer to Betsy's earlier alogs on contamination in BSC10 (10522, 10675 & 10686). There is still a lot of particulate contamination, even after cleaning. The first photo shows a wipe used to clean the tube on Monday. Dust, metal, a few red fibers, and white fuzzies were observed on the tube floor from the ACB all the way to the PCAL periscope. The iphone photos and videos don't really do it justice. There was a much higher concentration of white fuzzies along one half of the tube (on the right side, if you have your back to the ACB and are facing the periscope). Travis took an FBI sample, and then vacuumed the area.
After finishing PCal alignment, I replaced the 1" optic to it's original position between the purge air port and the ACB/ETM. I then wiped my way out of the chamber.