patrick.thomas@LIGO.ORG - posted 16:45, Tuesday 22 October 2013 (8219)
Set front panel settings on dust monitor 15
It appeared to have reset back to the default settings. I changed it back to location 15 from 1, to automatic from manual, and from a hold time of 1 sec to 1 minute.
H1 SUS
arnaud.pele@LIGO.ORG - posted 16:30, Tuesday 22 October 2013 (8212)
SRM OLV
OSEM NAME Open Light Value Norm Gain Offset  
M1 T1 27421 1.094 -13710  
M1 T2 25821 1.162 -12910  
M1 T3 29178 1.028 -14589  
M1 LF 28371 1.057 -14186  
M1 RT 26593 1.128 -13296  
M1 SD 26239 1.143 -13120  
M2 UL 28808 1.041 -14404  
M2 LL 26899 1.115 -13450  
M2 UR 28198 1.064 -14099  
M2 LR 25501 1.176 -12750  
M3 UL 27664 1.084 -13832  
M3 LL 28342 1.058 -14171  
M3 UR 26913 1.115 -13456  
M3 LR 25444 1.179 -12722  

Gains and offsets to center and normalize the signal of the osem between -15000 and 15000 counts have been calculated and are summed up in the summary table above.
Numbers have been entered in the medm and a new safe snapshot has been commited to the svn.
The excel chart E1200343 has been updated as well

H1 INS
jim.warner@LIGO.ORG - posted 16:14, Tuesday 22 October 2013 (8216)
BSC3 Payloaded, ready for HEPI floating

HughR, JimW

This afternoon BSC3 had its keel payload (~700lbs) added, so we are ready to float HEPI tomorrow afternoon-ish. Still odds and ends to add, like some optical table payload to simulate missing fiber guards, but, for now, close enough.

H1 SEI
hugh.radkins@LIGO.ORG - posted 16:04, Tuesday 22 October 2013 (8215)
WBSC3 SEI ISI CPS Racks Mounted & Grounded and all Sensor Cables Strain Relieved
All the CPS racks are strapped down to the unistrut, their power board target grounds are cabled to ground.  All the sensors: CPS GS-13 Trillium & L4-C cables are strain relieved at the Feed Thru Protection Shrouds.  The Actuator Cables have not been strain relieved.
LHO General
gerardo.moreno@LIGO.ORG - posted 15:57, Tuesday 22 October 2013 (8214)
Ops Shift Summary

- LN2 Delivery to CP7, currently on alarm status, currently at 98.5.
- Sheila escorting Karen in the PSL enclosure for cleaning.
- Sheila at the PSL, check/tweak alignment.
- Thomas to End-X ACB alignment, work aborted due to conflict with SEI crew.
- Kyle/Gerardo LVEA purge air work, replaced temperature sending unit, thanks Corey for the break.
- Filiberto, ISCT End-X, table cabling.
- Patrick running test code on Lab dust monitors, for days.
- Hugh to LVEA, external work in BSC03
- Richard End-X, reaction chain troubleshooting.
- Hugh and Jim, BSC03 payloading.

H1 AOS
stefan.ballmer@LIGO.ORG - posted 15:41, Tuesday 22 October 2013 (8213)
RTCG dependencies scripts in cds/common/scripts
Added the following scripts to cds/common/scripts
checkCompiledModel      : list all targets that use the specified model or library
checkTargetDependencies : list all models or libraries for specified target
dumpTargetDependencies  : simplified output of the above (requested by Jeff)

Example:
1) find all dependencies of h1susbs

>>checkTargetDependencies h1susbs

.mdl files:
Modify tag of model                         | Model name | SVN tag
=============================================================================
LastModifiedDate "Tue Jun 19 15:09:01 2012" | ODC.mdl |
LastModifiedDate "Tue May 7 14:11:17 2013" | h1susbs.mdl |
LastModifiedDate "Wed Jan 25 14:43:23 2012" | SIXOSEM_F_COILOUTF_MASTER.mdl |
LastModifiedDate "Thu Oct 6 15:33:48 2011" | FOUROSEM_COILOUTF_MASTER.mdl |
LastModifiedDate "Tue Aug 23 15:03:24 2011" | FOUROSEM_WD_AC_MASTER.mdl |
LastModifiedDate "Wed Aug 1 16:30:24 2012" | STATE_BIO_MASTER.mdl |
LastModifiedDate "Tue Oct 2 16:57:07 2012" | FOUROSEM_STAGE_MASTER.mdl |
LastModifiedDate "Thu Oct 11 09:59:06 2012" | SIXOSEM_F_STAGE_MASTER.mdl |
LastModifiedDate "Fri Sep 16 20:01:12 2011" | SIXOSEM_F_WD_DC_MASTER.mdl |
LastModifiedDate "Fri Sep 16 20:01:37 2011" | SIXOSEM_F_WD_AC_MASTER.mdl |
LastModifiedDate "Sun Oct 14 19:03:50 2012" | BSFM_MASTER.mdl |
LastModifiedDate "Wed Sep 7 14:37:51 2011" | FOUROSEM_WD_DC_MASTER.mdl |
LastModifiedDate "Fri Jun 7 16:34:37 2013" | QPD.mdl |
LastModifiedDate "Thu Feb 2 09:58:37 2012" | ISC_common.mdl |
Dependencies other than .mdl files:
=============================================================================
src files:
cds/common/src/ODC_ADD_PARITY.c
sus/common/src/CD_STATE_MACHINE.c
sus/common/src/WATCHDOG.c
=============================================================================

2) find all targets using QPD.mdl

>>checkCompiledModel QPD.mdl
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1ascimc |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1asc |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1iscex |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1iscey |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1psliss |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1susbs |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1susbstst |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1susetmx |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1susetmy |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1susitmx |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1susitmy |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1suspr3 |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1susquadtst |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1sussr3 |

H1 CDS
david.barker@LIGO.ORG - posted 14:28, Tuesday 22 October 2013 (8211)
h1seiex power cycled, IO Chassis power loss

The IO Chassis for h1seiex lost power. After it was restored we restarted the front end and user models.

H1 SUS
arnaud.pele@LIGO.ORG - posted 11:05, Tuesday 22 October 2013 (8210)
BS Sign check

After swapping the magnets on the beamsplitter, cf 8121, I tested the middle mass (M2) of the suspension by sending offsets to each osem, expecting to see the suspension being pushed with a positive offset, and vice versa.

Results are attached below with (1) the generic drive signal sent consecutively to each osem, and (2) the response (in um) of each osem to the drive. 

Not sure if it make sense that the lower right osem has a smaller amplitude than the others, but other than this the suspension is moving as expected.

Non-image files attached to this report
H1 PSL
sheila.dwyer@LIGO.ORG - posted 10:46, Tuesday 22 October 2013 - last comment - 16:20, Tuesday 22 October 2013(8209)
ref cav and ALS fiber alignment

After Karen and I cleaned inside the PSL this morning I had a look at the ref cav alignment.  When I started the tpd had 0.5 V, after adjusting mostly pitch it is at 1.18V.  Since this is back to just above what it was 4 weeks ago, I set the resonant threshold back to 0.9V. 

There is currently 8.9mW headed towards the fiber.  I used a fiber feedthrough to conect the two ends of the fiber that go to the ALS fiber distributuion box, and sent the light back into the PSL. Initaly there was 1.9mW coming out of the fiber, I would have expected more of a power increase from friday http:// https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=8193 because of the increase in the ref cav transmission.

I adjusted the alignment of the ALS fiber path and moved the ROC=100mm lens forward by about 1 cm to get 6.2mW out of the fiber, 70 % coupling efficiency. 

The fiber launch PD reading has increased to 0.73 mW, from 0.19 mW, so we should get about 3.8 times more power at the end station than what we measured friday, almost 100 uW.

Comments related to this report
alexan.staley@LIGO.ORG - 16:19, Tuesday 22 October 2013 (8217)

With this new ref cav alignment, I measured the power out of the fiber in EX to be 110 micro Watts.

alexan.staley@LIGO.ORG - 16:20, Tuesday 22 October 2013 (8218)

See alog 8209 for status update

LHO VE
kyle.ryan@LIGO.ORG - posted 10:00, Tuesday 22 October 2013 (8208)
Shut down LVEA purge air supply ~0845 - ~0945 for service
Kyle, Gerardo 
Replaced 2nd stage discharge air temperature RTD
LHO General
patrick.thomas@LIGO.ORG - posted 09:59, Tuesday 22 October 2013 (8207)
Testing dust monitor code in optics labs
~09:50 stopped code for optics labs, started test code on opsws8.
H1 SUS
jeffrey.kissel@LIGO.ORG - posted 21:45, Monday 21 October 2013 (8204)
SUS ECRs E1300578 and E1300261 Front-end Model and MEDM Screen Mods have begun
J. Kissel

I've begun modifying all layers of SUS front-end simulink models, in order to implement the approved changes described in ECRs E1300578 and E1300261. These changes include

- Moving the DRIVEALIGN matrix out of the DAMP/TEST/OPTICALIGN paths, such that it only operates on the LOCK path for each stage (and therefore reducing the size of the M0 / M1 version)
- Adding output switches after the internal SUS offloading, so -- in the "offloaded" hierarchy scheme -- one can send alignment signals straight to the top without zeroing out diagonal DRIVEALIGN matrix elements
- Removing the wasteful, unnecessary DRIVEALIGN path
- Making both DAMP and LOCK filter banks use cdsCtrlFilt, such that they produce a status bit word for ODC consumption during lock acquisition
- Defining the list of channels that shall stay in the science frames, to be stored for all time
- Removing obsolete L1 and L2 (lower stage) damping from the QUADs which had been needed for very early H2OAT operation before ISIs were turned on
- Removing the explicit definition of 2048 from the stored ODC DAQ channel, such that it is by default sored at the model's native rate as designed
- Adding a length-driven, (optical lever/OSEM) angle response lock-in for force-to-angle decoupling and tuning.


I've gotten through almost all the QUAD modifications (what I always start with first, because it's the most complicated, but the basis for every other suspension). However, I've hit a compile error which I don't understand, so I need Rolf's help in the morning.

For now the following models are changed, but uncommitted:

in the ${userapps}/release/sus/ folder:
M       common/models/HLTS_MASTER.mdl
M       common/models/SIXOSEM_F_STAGE_MASTER.mdl
M       common/models/BSFM_MASTER.mdl
M       common/models/MC_MASTER.mdl
M       common/models/OMCS_MASTER.mdl
M       common/models/HSTS_MASTER.mdl
M       common/models/FOUROSEM_STAGE_MASTER.mdl
M       common/models/TMTS_MASTER.mdl
M       common/models/QUAD_MASTER.mdl
M       h1/models/h1sustmsx.mdl
M       h1/models/h1sustmsy.mdl
M       h1/models/h1susprm.mdl
M       h1/models/h1sussrm.mdl
M       h1/models/h1suspr2.mdl
M       h1/models/h1susbs.mdl
M       h1/models/h1suspr3.mdl
M       h1/models/h1sussr2.mdl
M       h1/models/h1sussr3.mdl
M       h1/models/h1susetmx.mdl
M       h1/models/h1susomc.mdl
M       h1/models/h1susetmy.mdl
M       h1/models/h1susmc1.mdl
M       h1/models/h1susitmx.mdl
M       h1/models/h1susmc2.mdl
M       h1/models/h1susmc3.mdl
M       h1/models/h1susitmy.mdl

(the non-QUAD, top-level model modifications are left over from Stefan's ODC work, which I told him to leave uncommitted because I would be coming in right behind him making top-level mods.)
H1 SYS
stefan.ballmer@LIGO.ORG - posted 21:45, Monday 21 October 2013 (8205)
ODC master running
The new ODC master model is now running of h1oaf0. Its inputs are still epics inputs - as soon as the modified SUS and SEI models are running, we will add the IPC receivers. Also, the model currently only has 8 inputs. This will need to be scaled up for receiving all data.

There are also preliminary ODC master medm screens available from the ODC site overview.
H1 SUS
arnaud.pele@LIGO.ORG - posted 18:38, Monday 21 October 2013 - last comment - 18:47, Tuesday 22 October 2013(8194)
ETMX R0

Since phase 3a ETMX reaction chain transfer functions from thursday night didn't look good, Travis and Betsy went back in chamber on friday and moved back one of the top mass earthquake stop (one blocking the vertical direction). New series of transfer functions have been ran over the week end and are plotted in the attachments.

They now show a good match with the model and LLO measurements and moving the EQ stop definitely improved the results. Although, transverse still doesn't have any coherence with the drive, see second page of 2013-10-18[...].pdf attached

I checked the voltage at the output of the coil driver during the drive of transverse and the signal is clearly there, see image attached.

The attached results are described below :

(1) 2013-10-18[...] = Plot comparing R0 undamped TF phase 3a and the model

(2) allquads_[...] = Comparison between LHO R0 undamped TF phase 3a on friday night (2013-10-18), LHO R0 undamped TF phase 3a on thursday night (2013-10-18)

(3) Image = Screenshot of the drive signal of side osem at gps = 1066192865 (during transverse excitation) at (in red) the excitation test point, and (in blue) the coil driver output. Signals are coherent, meaning the chain between the dac and the coil driver is not broken

Images attached to this report
Non-image files attached to this report
Comments related to this report
arnaud.pele@LIGO.ORG - 18:47, Tuesday 22 October 2013 (8223)

Richard replugged satelitte box cables, and the actuation is now properly working on the side osem. Transfer functions are running overnight

LHO General
justin.bergman@LIGO.ORG - posted 15:51, Monday 21 October 2013 (8201)
ops

Things happening:

From Morning Meeting:

SEI payloading at EX

Kill circuit for Prometheus laser being installed at EX (temporary mount)

ISC table being craned into place at EX

HAM6 cabling

Doug/Jason alignment at EY

Apollo moving scissor lift from MY to EY

Insulators continuing on X1

 

830 ACE septic

849 Mount Lock and Key along X-arm

910 Patrick restarting lab dust monitors

955 Corey installing TMSX cabling

1042 Mayflower metals swapping scrap recyling bin

1128 Sprague onsite, two vehicles

1200 Forklift Service onsite

1441 DAQ restart for dust monitor work      

LHO General
patrick.thomas@LIGO.ORG - posted 15:01, Monday 21 October 2013 - last comment - 15:45, Monday 21 October 2013(8200)
Reverted back dust monitor code
This falls under WP 4198.

For the time being I have reverted the dust monitor code back to device support met_one_227b-1.0.1 and IOC dust_met_one_227b-1.0.4.

I stopped the test code running for the optics labs (which I had restarted on opsws8 this morning) at 14:04.

I copied the dust target directories from /ligo/lho/h0/target to /ligo/lho/h0/target_archive. I appended _october_21_2013 to them.
I copied the dust target directories with _october_8_2013 appended to them from /ligo/lho/h0/target_archive to /ligo/lho/h0/target.

I stopped the dust IOCs running on h0epics.
I started the reverted dust IOCs on h0epics2.

Dave reverted back the INI file and restarted the DAQ.

I burtrestored the IOCs with the files in /ligo/cds/lho/h0/burt/2013/10/07/00:00.
Comments related to this report
patrick.thomas@LIGO.ORG - 15:45, Monday 21 October 2013 (8203)
Dust monitor 3 kept stopping after this change. I went out and checked the front panel. The mode was manual and the hold time was 1 second. I changed the mode to automatic and the hold time to 1 minute. While I was out there I checked dust monitor 15. It turns out that it has no fuse in the breakout box. When I came back in the IOC for the dust monitors in the LVEA was giving errors. I restarted it and burtrestored it using the file in /ligo/cds/lho/h0/burt/2013/10/07/00:00.

To do: Put fuse in breakout box for dust monitor 15.
H1 ISC
alexan.staley@LIGO.ORG - posted 11:45, Monday 21 October 2013 - last comment - 15:28, Monday 21 October 2013(8193)
Fiber cable power

(Sheila, Alexa)

 

We measured the fiber coming out of the single-mode optical fiber at several locations. During the measurements the ref cav trans PD is reading .46 volts.

1.7mW from the PSL to the input of the ALS Fiber Distribution Chassis on ISCR1

127uW @ x-ouput of ALS Fiber Distribution Chassis

110uW @ MSR input

80uW @ MSR output

20uW @ EX

 

In comparison to alog 6341, we had 7.7mW from the PSL with a ref cav trans of 2 volts. So if we align the ref cav we will gain a factor of 4 power.  There was also only a 50% loss in power between the MSR output and EY in comparison to the 75% loss we are seeing. Hopefully we can gain some more power by cleaning the fiber cable.

Comments related to this report
alexan.staley@LIGO.ORG - 15:28, Monday 21 October 2013 (8202)

As per Richard's request, I doubled check the power coming out of the EX fiber more rigorously using a fiber cable and found the power to be 28uW.

X1 SUS
jeffrey.bartlett@LIGO.ORG - posted 10:16, Monday 21 October 2013 - last comment - 08:12, Tuesday 22 October 2013(8191)
Phase 1b Testing 3IFO-OMC
    On Friday I took the transfer function and power spectra data for phase 1b testing of the 3IFO-OMC suspension. The data has been plotted and compares favorably with the already pass Phase 1b testing data from H1-OMC. The plots are attached below and are ready for review by the testing group.  
Non-image files attached to this report
Comments related to this report
arnaud.pele@LIGO.ORG - 10:48, Monday 21 October 2013 (8192)

Results look good, and are approved for phase 1b

stuart.aston@LIGO.ORG - 08:12, Tuesday 22 October 2013 (8206)
Agree, no concerns at all, a really nice and clean set of measurements!

Great work the assembly and testing team!
Displaying reports 75581-75600 of 83537.Go to page Start 3776 3777 3778 3779 3780 3781 3782 3783 3784 End