H1 SEI
greg.grabeel@LIGO.ORG - posted 10:41, Tuesday 03 September 2013 (7603)
GS-13 SN 68
GS-13 pod number 68 arrived with damaged flexures from shipping some time ago. After replacing the broken flexures, re-sealing the pod and filling it with Neon, I leak checked it in the modified VBO A.

Initially I had some issues with an errant signal of Neon, but this was because I had forgotten to lower the ionizing voltage. Argon from a small air leak was doubly ionizing and appearing as Neon in the RGA. After lowering the voltage to 50v everything cleaned up nicely.

The GS-13 tested good, coming out under the 3e-10 torr L/s leak rate requirement set by the VRB.
Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 18:25, Saturday 31 August 2013 (7601)
CDS disk problems on cdsfs1 and h1fw0

cdsfs1 went into read-only mode Friday evening between 18:20 and 19:20. At 17:45 this afternoon I rebooted the machine using the standard recovery procedure. Backups are proceding.

While looking at the system overviews I noticed that h1fw0 is not running. It has been unstable from about 16:45 this afternoon. Unfortunately fw1 is not perfectly stable, it had failed around 3pm and 5pm with short restarts. fw0 cannot run for more than a few minutes without crashing.

The console message on h1ldasgw0 shows many errors of type:

samfs: WARNING: SAM-QFS: ldas-h1-frames: cannot flush pages err=43 ....

I called Greg, he and Dan will investigate further. Sometimes fw0 gets to run for 10 minutes before crashing, so I'll keep both frame writers going to minimize the possibility of complete data loss. Greg will switch LDAS to using h1fw1 as the primary frame source. 

H1 ISC
stefan.ballmer@LIGO.ORG - posted 16:08, Saturday 31 August 2013 (7600)
31h of IMC lock - some power fluctuations

Attached is a plot of the following 6 signals of that last 31h of IMC locking:

H1:PSL-FSS_FAST_MON_OUTPUT

H1:PSL-FSS_AUTOLOCK_STATE

H1:PSL-ISS_DIFFRACTION_AVG

H1:IMC-MC2_TRANS_SUM_OUTPUT

H1:PSL-FSS_TEMP_LOOP_OUTPUT

H1:PSL-PWR_NPRO_OUT_DQ

 

I didn't find a good PSL room temperature monitor, but I guess that all the fluctuations we see are temperature-induced in some form. See also elog 7593 for comparison.

Images attached to this report
H1 AOS
cheryl.vorvick@LIGO.ORG - posted 17:57, Friday 30 August 2013 - last comment - 22:12, Saturday 31 August 2013(7598)
TMSX telescope moved to the VEA and installed - TMSX cables attached to the table top
- Corey, Andres, Hugh, Keita, Cheryl

TMSX telescope moved by Genie from the TMS lab to the VEA.  The telescope suspension wires were attached, and the telescope is now suspended.  The upper mass is still locked by EQ stops.  The vertical safety wire is installed, and the swing stop assembly is positioned under TMSX.  A rod on the swing stop assembly goes through two eye bolts on TMSX, preventing it from swinging into the QUAD.

Gymnastics of turning the telescope 180 degrees was documented more thoroughly in pictures today.

The telescope safety support beams were installed Wednesday (my idea), which mean the Genie would not fit under the upper structure, so we rotated the front beam out of the way after removing 3 of 4 bolts.

I returned to EX after lunch and attached the 4 cables to the ISC table.  Cables come from the clamp in the center of the upper mass, attach to raised wire clamps, and connect to the cable brackets on the ISC table.  They will need further tweaking after the upper mass is freed, to make sure they are not touching.

Pictures added later.
Comments related to this report
corey.gray@LIGO.ORG - 11:02, Saturday 31 August 2013 (7599)

Here are a few action photos from the TMS Table/Telescope install yesterday (& as usual, ALL TMS photo documentation is on ResourceSpace, here).

Images attached to this comment
cheryl.vorvick@LIGO.ORG - 22:12, Saturday 31 August 2013 (7602)
Pictures showing telescope optics protected by Alpha wipes, the swing top assembly, and cables.

1 - view from the floor - swing stop assembly on the left - telescope optics covered with large Alpha wipes
2 - swing stop assembly attached to TMSX
3 - CB-7
4 - CB-8 cables to upper mass
5 - CB-8
6 - CB-7 cables coming from upper mass  
7 - CB-8  cables coming from upper mass
For the cables in pictures 6 and 7, the peek zip ties are temporary to ensure connectors don't fall on the TMS optics.
Images attached to this comment
H1 ISC
stefan.ballmer@LIGO.ORG - posted 16:13, Friday 30 August 2013 (7593)
6hrs of MC locking - ISS diffraction effeciency and FSS temperature control signal drift
The two attached plots show the following signals over the span of 6h (patch them next to each other):

Blue:   FSS control signal readback
Green:  FSS autolocker state
Brown:  ISS diffraction efficiency
Cyan:   IMC build-up
Yellow: FSS temperature loop control signal

Notable:
 - The ISS diffraction efficiency varied between 10% and 15%. This corresponds to an ISS loop gain variation of sqrt(0.15/0.10)~1.2, or about 20%.
 - The short lock losses were due to Ethercat reboots, resulting in IMC lock losses. The FSS never dropped below state 2, as is evident from the fact the the temperature loop did not forget its offset.
 - The IMC held lock through the magnitude 7.0 earth quake in the Aleutians this morning. The peak seismic signal at LHO was on the order of 20u/sec.
Images attached to this report
H1 SEI
hugh.radkins@LIGO.ORG - posted 16:12, Friday 30 August 2013 (7594)
WHAM6 HEPI Install Update
With the doors on and cleanroom now moved, I've installed all the sensors & electronics.  Quick look at spectra suggest things are OK.  The HEPI is still locked and the Vertical L4-Cs still need to be leveled and protected.  There remains some cable dressing as well.  Please be mindful of the sensors and cables at this location.
H1 General
jeffrey.bartlett@LIGO.ORG - posted 15:49, Friday 30 August 2013 (7592)
Ops Summary
09:00 Cory, Cheryl, and Andres at End-X to move and attach TMS OB/Telescope
09:32 Betsy & Travis working on ITM-X
09:41 Richard at ITM-X working on SUS electronics
10:15 Justin check out dust alarm in Bake Out lab
10:15 Bubba/Apollo in LVEA working on cleanroom move
13:15 Thomas Vo Recycled EtherCAT in corner station
13:26 Hugh at HAM6 working on HEPI electronics
14:11 Andres dog clamping SR suspensions to optics table
14:32 Cheryl at End-X working on TMS
LHO VE
kyle.ryan@LIGO.ORG - posted 15:08, Friday 30 August 2013 (7591)
X-end purge air still running on 4 of 5 compressors
I attempted to replace Compressor #1's "noisy" scroll but the new scroll (SLAE05E) is not a direct substitute for the legacy scroll (SLAE05) -> I'll attempt to acquire the old part number or make a custom mount if needed (next week)
H1 SUS
betsy.weaver@LIGO.ORG - posted 14:09, Friday 30 August 2013 - last comment - 16:25, Friday 30 August 2013(7590)
ITMx SUS - update

We've connected all of the cables on the ITMx QUAD and all 20 OSEMs have some sort of signal coming out to medm.  Thanks Richard for some power and rack troubleshooting on QUADTST.  There is some strangeness on the medm so Arnaud is looking into what model version is loaded on the QUADTST testbed.  The main chain does not damp so we likely have crossed signals or a sign flip somewhere...?  More from him to come.

Comments related to this report
arnaud.pele@LIGO.ORG - 16:25, Friday 30 August 2013 (7595)

Damping gains were still set to their old values. They are now set to -1, which is the convention for filter gains. Coilouput gains and signs have been checked, and are in accordance with the magnet convention (+ sign = north pole magnet, and vice versa).

H1 ISC
corey.gray@LIGO.ORG - posted 21:02, Thursday 29 August 2013 (7589)
Table/Telescope Not Installed (Ready To Go)...Continued Cabling Work

The Continued Story of CB3

On Wed, there were unresolved issues with cabling for the TMS.  The main issue was a cable bracket (CB3) which, on a drawing, is supposed to be on the east side of the table (i.e. -Y side of TMS), but having it here has limited access, and it would be even worse after we box it in when the Table/Telescope was installed.  

Now the cables (TMS OSEMs) which use CB3 eventually run to a feedthru which is quite on the other side of the TMS (i.e. the +Y side of it); on this side of the TMS there is lots of open space & getting to the feedthru is trivial.  So, after consulting with Cheryl/Mike/Calum, Jeff & I decided to move CB3 from it's "called out" location on the "edge" of the table to roughly the center of the table.  So, the "quadrapuss" OSEM cable D1000234 was run to this feedthru (and excess bundled near bracket), then D1000225 was run straight "north" on the table and out to a spot where Jim W suggested---then he'd be able to dress it on the ISI and on to the feedthru.  The beauty of this cable run is that we have elegant access to the cables & cable bracket.

This leaves us ready at the Cartridge to bring in the Table/Telescope.  

Table/Telescope Installed On Test Stand:  Promise!

Throughout the day, I also prepped the Table/Telescope for the trip form the TMS Lab to the Test Stand.  I blew off the Telescope Mirrors, installed the TMS Cover (to protect Table optics), and arranged the Genie and Table/Telescope for the move first thing tomorrow morning.

Attached are photos of how Jeff B. ran the cabling and where he positioned CB3 (the D1000225 has about 14' of cable and it is coiled on the table ready to be grabbed by SEI for final dressing to feedthru).

Images attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 18:33, Thursday 29 August 2013 (7588)
plots of dust counts
Attached are plots of dust counts requested from 4 PM August 28 to 4 PM August 29.
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 18:30, Thursday 29 August 2013 (7587)
plots of dust counts
Attached are plots of dust counts requested from 4 PM August 27 to 4 PM August 28.
Non-image files attached to this report
H1 AOS
stefan.ballmer@LIGO.ORG - posted 17:57, Thursday 29 August 2013 (7586)
investigation of EY drift event of 07/19/2013 00:00 UTC

To tie up some loose ends, I went back to the EY drift event of 07/19/2013 00:00 UTC (elog 7146), which was triggered by turning off the clean room.

The attached plot 1 shows 20 days around the event. Marked in dark blue is the turn-off event, marked in bright clue is the turning on of the same clean room a day after. I am not sure where exactly the two temperature sensors are located, but I amsure the actual temperature jump at the BSC was bigger (From John's elog 7149 is was >2degF).

According to the OSEMS the TMSY drifted by about 5 urad in pitch and yaw (ignore sharp steps due to realignments) - I don't think that can be responsible for us falling off the photodiode. so something else must have moved.

The ETMY is even less: ~2urad in pitch and nothing significant in yaw (plot 2).

The PZT actuators (under QPD control, slaving the beam to the TMS) show some shift, but nothing that would be very unusual.

So the bottom line is: I still don't understand why we fell of the diodes on ISCTEY that day.

 

 

 

 

'

Images attached to this report
LHO VE
kyle.ryan@LIGO.ORG - posted 16:33, Thursday 29 August 2013 (7585)
Corner Station RGA
I have been trying to familiarize myself with Rai's "hydrocarbon" RGA (software and apparatus) which is mounted on the East door of HAM3 and have included some preliminary scans taken today.  These aren't intended to contribute to the eventual analysis but are interesting nonetheless.  It looks to me like the lack of distinct hydrocarbon peaks will necessitate an accumulation on the RGA's 80K "cryo finger".  We may need to compare scans with and without CP2.  

Rai has already used this same setup to quantify the hydrocarbon partial pressures at the Y-end and has commented on the expected impact on aLIGO mirrors (see T1100561, T1100642, T1200021 and T1200395). 

Note: these .pdfs contain "sticky notes" without which these scans won't have much meaning
Non-image files attached to this report
LHO General
hernan.daveloza@LIGO.ORG - posted 16:02, Thursday 29 August 2013 (7584)
Ops Summary

- Apollo crew working on the floor of End-Y.
- Apollo installed HAM door in LVEA.
- Arnaud was taking TF of the BS.
- Dust monitors location updated (I guess Patrick did it).
- Richard went to mid-X to check equipment.
- Dave installed firefox on left operator's computer for camera views.
- Dave copy firefox's folder after crash (lost bookmarks) on main operator computer.
- Rick and Christina (her last day) working on PSL.

 

pablo

H1 SEI
vincent.lhuillier@LIGO.ORG - posted 15:59, Thursday 29 August 2013 (7582)
ISI - BSC1 and BSC2 at the requirements

Last night, I left the two ISIs at the corner station with the aggressive feedback isolation filters and the feedfoward engaged. HEPIs are just controlled in position (100mHz UGF). Configurations were almost identical (cf item 5) on both ISI (low blend on translations and high blend on rotations to limit noise injection).

I have attached spectra of the stage 2 motion in the Y direction.
Note that:
1- ISIs didn't trip during a long stretch of time. The control is very robust (the ITMY feedback filters were even designed with the HEPI locked)
2- The stage 2 motion in the Y direction meet the requirements for both ISIs
3- The performance are similar for both ISIs
4- The feedforward control allows squashing the HEPI pier resonance on ITMY (feedforward filters clearly need to be reworked on BS)
5- ITMY performs slightly better than BS at low frequency. I noticed that the sensor correction was engaged on stage 2 in the Y direction. It might explain the difference

Images attached to this report
H1 SUS
arnaud.pele@LIGO.ORG - posted 16:27, Friday 23 August 2013 - last comment - 17:04, Friday 30 August 2013(7525)
ITMX open light values

For future reference, open light values have been taken for ITMX currently at the test stand (QUADTST on medm)

M0F1 22745      1.319 -11372
M0F2 25209      1.190 -12604
M0F3 25497      1.177 -12748
M0LF 25276      1.187 -12638
M0RT 24820      1.209 -12410
M0SD 23964      1.252 -11982
R0F1 25057      1.197 -12529
R0F2 30488      0.984 -15244
R0F3 29015      1.034 -14507
R0LF 29178      1.028 -14589
R0RT 27580      1.088 -13790
R0SD 27366      1.096 -13683

Comments related to this report
betsy.weaver@LIGO.ORG - 08:07, Monday 26 August 2013 (7532)

Here are the serial numbers inserted with the measured values:

 



M0F1    22745      1.319 -11372    SN 091

M0F2    25209      1.190 -12604   SN 494

M0F3    25497      1.177 -12748   SN 482

M0LF    25276      1.187 -12638   SN 509

M0RT    24820      1.209 -12410   SN 490

M0SD    23964      1.252 -11982   SN 111

R0F1    25057      1.197 -12529   SN 470

R0F2    30488      0.984 -15244   SN 467

R0F3    29015      1.034 -14507   SN 127

R0LF    29178      1.028 -14589   SN 115

R0RT    27580      1.088 -13790   SN 664

R0SD    27366      1.096 -13683   SN 080


 



		
		
arnaud.pele@LIGO.ORG - 17:04, Friday 30 August 2013 (7597)

Lower masses open light values for lower masses for ITMX (currently on quadtst) have been recorded

osem name   olv          gain     offset          serial number

L1UL             31509     0.952    -15755             439
L1LL              29214     1.027     -14607            510
L1UR            26506     1.132     -13253             474
L1LR             27979     1.072     -13989             487
L2UL             21877     1.371     -10938             146
L2LL              22829     1.314     -11414             263
L2UR            24994     1.200     -12497              112
L2LR             22583     1.328     -11291             463

Displaying reports 77341-77360 of 84706.Go to page Start 3864 3865 3866 3867 3868 3869 3870 3871 3872 End