Displaying reports 78141-78160 of 86323.Go to page Start 3904 3905 3906 3907 3908 3909 3910 3911 3912 End
Reports until 15:55, Friday 08 November 2013
H1 General
jeffrey.bartlett@LIGO.ORG - posted 15:55, Friday 08 November 2013 (8448)
Ops Summary
TSC Install work at BSC1, 2, 3 from 16:00 to 00:00 Friday 8th
Electronics cabling work at HAM6
Apollo craning various items in the LVEA
Apollo working on spool install at End-X

09:02 Patrick & Thomas working on IOO Rotation State in H1-PSL enclosure
09:13 Hugh & Mitch HEPI actuator install at BSC3 
09:20 Cheryl working at HAM2/3 and in the H1-PSL
10:05 Kyle working on GV6
10:15 Dave add SUS ITM-X to IOP watchdog
11:45 Justin transition LVEA South bay to local laser hazard
13:15 Frank & Louis pulling cables at End-Y
13:25 Dave recycling H1SUSETMY
13:40 Keita & Koji in H2-PSL enclosure working on OMC
H1 SEI (CDS, SEI)
hugo.paris@LIGO.ORG - posted 15:27, Friday 08 November 2013 (8447)
HEPI Science frame Channels Added

Adjusted channel names in the master model of HEPI so channels would be recorded in the science frame - Per E1300742

Commited the new master model (hepitemplate.mdl)  -r6229

Every HEPI model of H1 (11) was restarted.

Restarting HEPI-HAM2, and then the DAC added 25 channels to the science frame, as expected.

Restarting HEPI HAM3, HAM4, HAM5, HAM6, ETMX, ITMX, BS,ITMY, ETMY, and then the DAC, added 225 (9*25) to the science frame.

Work was performed under WP# 4256 which is now closed.This was performed in the scope of Bugzilla bug #385

Details are attached in log file.

Images attached to this report
Non-image files attached to this report
H1 INS (INS)
jodi.fauver@LIGO.ORG - posted 14:51, Friday 08 November 2013 (8446)
Apollo work for 07 Nov 2013
We performed in the three-ring circus today. 

There were many items that needed to be craned into position in the LVEA in preparation for both this weekend's and next week's work: the Work Space cleanroom from the X Arm Spool area went to the south side of BSC1 for viewport installation, an additional work table and two shelving units for OFI assembly were needed in the West Bay and an enclosure was flown to the optical table at the foot of the mezzanine stairs for IO modification. All that activity took place this morning.

Work related to the X End reconfiguration continued. The Work Platform was transported to Y End. The E-Module was picked, turned and placed by BSC5. The BSC Storage Container Top was hauled to the End to be mated with the bottom and then the entire unit was moved back to X Mid. The spool piece was transported from X Mid to X End and placed in the VEA. That concludes the dirty work on the checklist and the space is ready for a good cleaning on Monday morning.

After lunch, we worked on modifying the Work Space cleanroom at the south door of BSC1 for TCS viewport install under clean conditions. The cleanroom and surrounding area were cleaned. Mark and Thomas started viewport installation at about 2:45 pm.  Once Mark is done with that, he will make an entry into BSC3 to remove the dust/laser barriers so that BSC1-2 are accessible for TCS install over the weekend. The barriers will be stored in the west nozzle of BSC3.

LHO VE
kyle.ryan@LIGO.ORG - posted 14:24, Friday 08 November 2013 (8445)
Helium leak tested 5 of 5 gate annulus CFFs on GV6
Kyle

Used LD to back "hung" 50 L/s turbo -> LD baseline at start of testing = 2.3 x 10-9 torr*L/sec helium indicated -> 20 sec audible helium blast at each gate annulus CFF joint on GV6 -> no response -> LD baseline at end of testing 2.2 x 10-9 torr*L/sec helium indicated -> Briefly energized annulus ion pump controller and observed expected cross-talk helium indication -> Restored GV6 annulus pumping to 50 L/s turbo backed by scroll pump -> Leaving GV6 hard-closed and will continue pumping combined annulus volume over the weekend
H1 CDS (SUS)
david.barker@LIGO.ORG - posted 12:12, Friday 08 November 2013 (8442)
susb123 IOP Watchdog Changes

WP4225

I modified the h1iopsusb123 model to add ITMX into the software watchdog switching logic. At the request from Jeff K and Arnaud P, I ammended the WP4225 to include replacing the RMS+DC OSEM parts with the RMS-ONLY OSEM parts. Note these are temporary parts since they have their DC monitors completely removed. After the upgrade to RCG2.8 I will install the new OSEM parts which monitor DC but will not trigger on them.

The install procedure was: kill user models (h1susitmx, h1susitmy, h1susbs), restart the IOP, test the watchdogs to SEI BSC1,2,3, restart the user models. I pressed the DIAG-RESETs to clear latched IPC errors.

I modified the WD MEDM screens accordingly.

This closes out WP4225.

LHO VE
kyle.ryan@LIGO.ORG - posted 11:38, Friday 08 November 2013 (8441)
Removed 1.33-2.75 flex piping from GV6's North gate annulus port-replaced with blank flanges
Kyle, Chris

GV6 cammed hard closed during the night -> Vented combined annulus volume -> Removed 1.33-2.75 flex piping from North gate annulus pump port and installed blanks in its place -> Began pumping combined annulus volume -> Will helium leak test new joints after lunch 

GV6's 2-way selectable electro-pneumatic manifold was leaking instrument-air noticeably when left last night -> it is not leaking after GV6 has cammed closed.  GV6's "unwillingness" to cam closed could be the result of insufficient net air pressure at the piston due to the excessive leak at the manifold or hard/non-compliant O-rings etc. or a combination of both, the important result is that it is not due to a "draped" gate annulus O-ring!
H1 PSL (PSL)
stefan.ballmer@LIGO.ORG - posted 11:08, Friday 08 November 2013 - last comment - 13:08, Friday 08 November 2013(8440)
PMC (and whole PSL) working again
(Richard, Stefan)

After some tail chasing (which included verifying that the spare PMC board works too), we found the 35MHz PMC EOM feed cable ripped out of the connector.
Fixing this obviously restored all PSL functionality. A better connector is currently being installed.

I also did a burt-restore to 10/26/2013 9am UTC (back when it was still working) to make sure we didn't pick up any spurious settings.

Comments related to this report
stefan.ballmer@LIGO.ORG - 13:08, Friday 08 November 2013 (8443)PSL
Phil fixed the connector - the PMC is now working again.

The EOM cable length changed by maybe 2in in the process - we did not re-phase it now because the beam is needed for HAM2 work.
H1 SEI (CDS, SEI)
hugo.paris@LIGO.ORG - posted 10:54, Friday 08 November 2013 (8439)
Updated SITEMAP

I corrected the macro substitutions for HEPI-EX in the SITEMAP.adl.

The sitemap was commited. -r6226

Pending changes regarding iscex were commited as well:

Index: SITEMAP.adl
===================================================================
--- SITEMAP.adl (revision 6172)
+++ SITEMAP.adl (working copy)
@@ -599,7 +599,7 @@
  display[7] {
  label="Communications Overview"
  name="$(USERAPPS)/sys/common/medm/SYS_CUST_COMMUNICATIONS_OVERVIEW.adl"
- args="%(read $(USERAPPS)/isc/common/medm/iscex_macro.txt)"
+ args="%(read $(USERAPPS)/isc/common/medm/iscex_macro.txt), USERAPPS=$(USERAPPS), SITE=LHO, site=lho, IFO=H1, ifo=h1"
  }
  clr=14
  bclr=60
 
Index: SITEMAP.adl
===================================================================
--- SITEMAP.adl (revision 6172)
+++ SITEMAP.adl (working copy)
@@ -599,7 +599,7 @@
  display[7] {
  label="Communications Overview"
  name="$(USERAPPS)/sys/common/medm/SYS_CUST_COMMUNICATIONS_OVERVIEW.adl"
- args="%(read $(USERAPPS)/isc/common/medm/iscex_macro.txt)"
+ args="%(read $(USERAPPS)/isc/common/medm/iscex_macro.txt), USERAPPS=$(USERAPPS), SITE=LHO, site=lho, IFO=H1, ifo=h1"
  }
  clr=14
  bclr=60
H1 ISC
alexan.staley@LIGO.ORG - posted 09:19, Friday 08 November 2013 - last comment - 15:39, Thursday 05 December 2013(8437)
ISCTEX mode matching

(Alexa, Sheila)

I am still puzzled by some of the mode matching measurements I took of ISCTEY. I had attemped to compare the accuracy of the Mode Master, Nanoscan, and Knife edge. They seem to approximately agree, but it's hard to say which is most accurate.

Regardless...I examined the beam profile exiting the table enclosure with all the lenses in place using the Mode Master. Refering to D1100607-v13, I found the optimal placement of the telescope to be: ALS-L6 13.5 inches from ALS-M9, ALS-L7 6 inches from ALS-M10. With an "a la mode" script, I determined the mode matching overlap with the TransMon secondary mirror to be 87% for the horizontal profile and 98.6% for the vertical profile. This overlap was computed with a 2.2mm waist at 3.5m from ALS-M11. The waist size and location was determined via T1200200-v1, D0902163, D1201457 as done in the ISCTEX MM alog with a correction of 4ft for the panel location change between EX and EY.

I have attached the scripts and MM snap shot. Note: the first matlab script is just the profile taken by the MM after the telescope, along with the overlap computation. The second script contains the full profile of ISCTEY, which is where some of my confusion persists.

Images attached to this report
Non-image files attached to this report
Comments related to this report
alexan.staley@LIGO.ORG - 15:39, Thursday 05 December 2013 (8843)

I examined the beam width with the Mode Master, NanoScan, and Knife Edge on the ISCTEY with ALS-L5 in place (22inch from M6); however, prior to the telescope. Comparing the three measurements at approximately the same location away from the laser (z=0), I found:

Knife Edge:

z = 2.794m        beam radii = .37mm

Nanoscan:

z = 2.756 m       beam radii (horz) = .40mm     beam radii (vert) = .43mm    ** careful, data point was not taken at the exact same location as MM or knife edge

Mode Master:

z = 2.794m        beam radii (horz) = .40mm      beam radii (vert) = .42mm

These measurements are within ~ 10% of each other.

H1 AOS (SEI, SUS)
jason.oberling@LIGO.ORG - posted 19:15, Thursday 07 November 2013 (8434)
WBSC3 ITMx & ACB Alignment

Two-fer tonight

ITMx Alignment

IAS: D. Cook, J. Oberling
SEI: H. Radkins, G. Grabeel, M. Robinson
 
Aligned the yaw of the ITMx and took a pitch measurement.  Position alignment remains unchanged from alog 8403.

IAS is now on hold until the HEPI actuators are attached; we will then take another look.  At some point after that we will have to do a small pitch correction.

ITMx ACB Alignment

IAS: J. Oberling
SLC: T. Vo
 
Aligned the ITMx ACB laterally and vertically tonight.  The errors are as follows:

All is within spec and good to go.

H1 CDS
sheila.dwyer@LIGO.ORG - posted 18:31, Thursday 07 November 2013 - last comment - 10:52, Friday 08 November 2013(8433)
epics communication with corner plc2, timing system

Something was wrong with communication between the cornner beckhoff plc2 and epics.  When I tried to change something in an medm screen, it would not change,  When I stoped PLC2, it would change the value on the medm screen.  Also, on the LSC refl common mode board medm screen, things were just continuously flipping, altough on the twincat side nothing seemed to be changing.  I tried commenting out all the changes I had made to the PLC, which didn't change the situation, tried rebuild all, clean all.  I tried shutting everything on the etchercat machine down and running the installation scripts again,  the epics did not come back.  Dave restarted the epics gateway, and things seemed to come back (at least from the other PLCs).  I was able to change values on medm screens, but the change didn't make it to the twincat side.  Then patrick suggested rebooting h1ecatc1, so I did and that seems to have fixed the problem. Adding back in my changes one at a time did not reproduce the problem. 

ALso, the timing system erros are back, Xend, Y end and Corner.  I'm not sure why.

 

Comments related to this report
daniel.sigg@LIGO.ORG - 10:52, Friday 08 November 2013 (8438)CDS

Yesterday, we swapped the end link chassis in End Y to the H1 version which has the safety terminals on a separate rail. We only realized now that this required a change in the system manager to remove the safety terminals left from the H2 system. The system is running again properly.

H1 AOS
corey.gray@LIGO.ORG - posted 16:03, Thursday 07 November 2013 (8417)
Ops DAY Summary

Day's Activities:

Hugh/Greg working on HEPI for ITMx this morning

SUS restart required for MC mirrors (for Cheryl work later).

Stefan/Sheila investiagting PSL issues

Justin prepping South Bay for Laser Hazard transition

Jim balancing BSC3

Thomas getting ready for ACB alignment (with Doug/Jason?)

Alexa transitioned Squeezer Bay Area to Laser SAFE

Kyle swapping states of GV5 & 6 over night (GV6 may cam shut, causing a BIG BANG, so just be mindful of this expected occurrence)

Lots of moving around infrastructure at EX

LN2 at MX CP5

Roofers at Y1

LHO VE
kyle.ryan@LIGO.ORG - posted 15:56, Thursday 07 November 2013 (8432)
Leaving GV6 with 50 psi applied to top of pneumatic piston overnight
Hopefully GV6 will cam closed at some point tonight -> will increase pressure to 75 psi tomorrow otherwise
H1 SEI
hugh.radkins@LIGO.ORG - posted 15:33, Thursday 07 November 2013 - last comment - 07:56, Friday 08 November 2013(8430)
WBSC3 ITMx HEPI Moves for IAS & now locked for ACB

As Jason logged yesterday, the ITMx was good except for the Yaw.  SEI turned the HEPI DSCW Springs to correct the Yaw error; we brough it from 1.6mrad to 35urads.  We then checked and leveled the Optical Table.  It was only barely out of spec with 0.3mm over the table; we got it to <0.2mm just hitting our 100urad goal.  With the Optical Level using TGT402 for reference, the OT is 0.6mm high.  I locked the HEPI after final DI readings for ACB work.

With these Yaw and Level adjustments, some unintended motion occur but they are small.  Based on the Dial Indicators, the platform moved 0.1mm South, 0.2mm East, & 20urads CW since the observations IAS took. We should be in OK shape.

Attached find my log book pages for this saga.  Thanks, to GregG & MitchellR

Non-image files attached to this report
Comments related to this report
hugh.radkins@LIGO.ORG - 07:56, Friday 08 November 2013 (8435)

Thanks too of course to Jason & Doug for IAS.

LHO General
john.worden@LIGO.ORG - posted 11:53, Thursday 07 November 2013 - last comment - 15:37, Thursday 07 November 2013(8420)
Roofing Progress

Weather has slowed the roofing work a little but still good progress has been made, Metal trim appears to be complete on the outbuildings and the electricians are restoring the lighning protection.

At the corner the upper decks are completed with membrane, Trim work is in progress and detail work around our staircase is largely done. The OSB membrane is more than 50% done. The projected finish is the 3rd week of November.

Images attached to this report
Comments related to this report
john.worden@LIGO.ORG - 15:37, Thursday 07 November 2013 (8431)

RE: 3rd photo - chalk line dust - NOT blood.

H1 SUS (CDS, DAQ)
jeffrey.kissel@LIGO.ORG - posted 23:11, Wednesday 06 November 2013 - last comment - 14:05, Friday 08 November 2013(8414)
ECR E1300578 Progress -- Never Closer
J. Kissel, D. Barker, J. Batch, A. Pele

Another harrowing day of front-end code changes. 

In summary, I've now completed and committed all the simulink / front-end model, MEDM screen, and macro file modifications for the HLTS, HSTS, and OMCS. This involved several more recompiles, reinstalls, restarts, and restores of all 10 models involved, a couple of more crashes and restarts of the DAQ, and a whole lot of eye-crossing details. The final modification -- to the OMCS front-end code -- has crashed the h1sush56 front end again (as the rest of these installs have, save h1sush2a for some reason), and almost undoubtedly because of the usual mx_stream failure. Thankfully, if did not crash the rest of the DAQ, so data taking should still hold over night.

Though I'm confident every thing I've done is legit, we should give a day to get things back up and running before we officially release everything to LLO. (Though I know they're not interested in more changes until they vent next Wednesday.)

Of note -- It was not until I got to the MC_MASTER parts today, and getting some feedback from ISC folks that I realized -- for calibrated, interferometric control channel purposes (think IMC_X, PRCL, SRCL, MICH, DARM) -- we need to send out the output of each LOCK filter bank (including the top stage) to the top level to be sent over IPC to the OAF / Calibration model. For those SUS that aren't involved in global control, we'll just terminate the unused connections at the *top-level* of each model (currently only h1susmc2 is *actually* using this type of spigot to form IMC_X, the remaining IFO DOFs' control signals are pulled out for calibration in the LSC model). There are a couple of ways to do the calibrated channel thing; I'll bring up with ISC / Systems as to how we want to do it (because it's currently inconsistent across the ISC / IO models). Unfortunately, this means I've gotta go back to the QUADs and BSFM, but I'll wait for the discussion to conclude before I do so.

Next on the chopping block -- tackle the severe upgrades and merging needed on the HAUX / HTTS models. Then that finally, finally, OMG finally, will close out this gosh darn ECR. Then we can do it all over again with the watchdog modifications. #facepalm.
Comments related to this report
keith.thorne@LIGO.ORG - 06:12, Thursday 07 November 2013 (8415)
It would be worth checking that scripts use to restart the mx_stream each front-end (such as /etc/start_streamers.sh ) are simplified to just do an mx_stream restart (i.e. /etc/init.d/mx_stream restart).  The /etc/init.d/mx_stream script is customized to specify the MX slot and destination port on the the data concentrator.  Old versions of /etc/start_streamers.sh did not call /etc/init.d/mx_stream but did their own restart that used slot 0, port 0 instead of unique slot/port.  
jeffrey.kissel@LIGO.ORG - 14:05, Friday 08 November 2013 (8444)CDS
CDS has brought all associated front-ends back up (see details in LHO aLOG 8424), and we've confirmed that we can get damping loops running and excitations can be sent out. As such, these modifications described above are clear of flaws, and are therefore ready for LLO to install.
H1 SUS
arnaud.pele@LIGO.ORG - posted 17:01, Wednesday 06 November 2013 - last comment - 17:16, Tuesday 15 April 2014(8409)
PRM TF round 2

Last friday, Betsy and Travis added weight to the middle mass of SRM currently on the test stand, in order to center the flags with the osems cf alog 8367. A first round of TF have been taken before that, showing clean measurements. A new set have been taken monday night to assess that there's no major change. The new results are showing an excellent match with the previous ones
 

Results in attachments are described below :

(1) H1 SUS SRM M1-M1 (top mass) comparison between modeled and measured undamped transfer functions for the 6 dofs

(2) H1 SUS SRM M1-M1 comparison between modeled and measured damped transfer function for the 6 dofs

(3) H1 SUS SRM M1-M1 undamped TF comparison before and after adding weight to the middle mass

data have been commited under the svn

Non-image files attached to this report
Comments related to this report
arnaud.pele@LIGO.ORG - 08:47, Friday 08 November 2013 (8436)

I meant SRM in the title

arnaud.pele@LIGO.ORG - 17:16, Tuesday 15 April 2014 (11369)

For acceptance review I also added the spectra of SRM during phase 2b (currently plugged on the test bench).
The first 3 pdfs are showing the effect of the top mass damping on each stage. The last two pdfs are comparing SRM spectra with other hsts suspensions (PRM and SR2) during phase 2b, damping off and damping on.
Everything looks good for all osem signals, damping is working fine by significantly reducing the Qs of the resonances, and both damping on and off spectra are similar to other HSTSs at the same 2b stage of testing.

Non-image files attached to this comment
Displaying reports 78141-78160 of 86323.Go to page Start 3904 3905 3906 3907 3908 3909 3910 3911 3912 End