Reports until 11:11, Thursday 28 February 2013
H1 General
hugo.paris@LIGO.ORG - posted 11:11, Thursday 28 February 2013 (5605)
HAM-ISI Electronics - Cable moved

Moved the STS cable one AA chassis up for both HAM2-ISI and HAM3-ISI, in order to be consistent with latest wiring diagrams, and their associated models.

H1 PSL
michael.rodruck@LIGO.ORG - posted 23:39, Wednesday 27 February 2013 (5604)
Chiller woes

I replaced the broken fitting on the diode chiller today but it would not start due to a low flow error. The flow will reach a max of 2 lpm before shutting off after a few seconds. I short circuited the flow to the chiller and got the same error, so the issue is with the chiller itself. We'll likely need the spare chiller from the H2 room, but will have to flush it out as there is some algae in the water tank.

H1 IOO
cheryl.vorvick@LIGO.ORG - posted 22:14, Wednesday 27 February 2013 (5603)
IO work in HAM2 Continues:
- Deepak, Kyohei, Travis, Cheryl

More dog clamp swaps and installation of components.  Some components were moved to allow new hardware installation in HAM2 .

Highlights of work completed:
- PRM AR Baffle installed
- PRM EQ Stop Baffle installed
- MC3 EQ Stop Baffle dog clamps swapped
- dog clamp mess in front of IM1 cleared up, though one baffle now has dog clamps only on one side, which is not ideal, so maybe some small changes still to come there
- dog clamp serial numbers and types collected

Still to do:
- modify IM4 baffle - didn't fit today, but slop in washers used as spacers may allow a fix
- FI rejected beam dump needs to be assembled and installed
- a few dog clamps to work on, less than 5
- OpLev optic still to install on North side of the table
- move one baffle, which requires climbing into the chamber on the South side
- pictures of the changes
- check alignment of every component!  Components moved without an alignment beam, so minor adjustments may be needed on multiple components.
H2 SEI
hugh.radkins@LIGO.ORG - posted 16:58, Wednesday 27 February 2013 (5602)
WBSC8 HEPI/iLIGO CAS Swap Update 1/2 complete
The SE corner has now been swapped back to iLIGO SEI.  More to go tomorrow.
H1 SEI
hugh.radkins@LIGO.ORG - posted 16:56, Wednesday 27 February 2013 (5601)
Dial Indictors moved from BSC1 to BSC2
Bumping the DIs really don't matter at this time as they aren't logging anything.  Still try to not bang into them anymore than needed for their well being.
H1 SEI
hugh.radkins@LIGO.ORG - posted 16:53, Wednesday 27 February 2013 (5600)
LVEA HEPI Leak Check Update
Found the leak I was looking for; it was lurking SE of HAM4.  The Apollo welder was fortunately available and repaired it early afternoon.  All the Valves have been opened again and the pressure brought back up to 125psi.  Will report tomorrow on how it is doing.
H1 INS
jodi.fauver@LIGO.ORG - posted 15:46, Wednesday 27 February 2013 (5599)
BSC2 Install Prep Checklist
Build custom bridge between work platform and e-module
Install central curtains on garbing/staging cleanroom
Move cleanroom from HAM aux optics table to BSC2-HAM3 for garbing/staging
Work on cleanroom curtains: "doorway" at bridge?
Clean chamber and cleanroom X 2
Check cleanroom function
Stage garbing/staging cleanrooms
Baffle assembly (Clean test stand-solid stack to test stand ~28 Feb-work tables moved in-clean cleanroom and contents prior to assembly start)
H1 INS
jodi.fauver@LIGO.ORG - posted 15:45, Wednesday 27 February 2013 (5598)
BSC10 ICC
FTIRs taken. Permanent BSC flooring installed. Doors returned to chamber.
Cleanroom placed over dome late yesterday afternoon. Dome and cleanroom cleaned today. Dome will be cleaned and returned to chamber tomorrow.
H1 CDS
david.barker@LIGO.ORG - posted 13:34, Wednesday 27 February 2013 (5597)
Most MSR front ends restarted due to dolphin error

We accidentally glitched the Dolphin network in the MSR this morning while investigation a model which is running long. We had to restart almost all the models on Dolphin connected front end computers. The reason for the glitch is known and we can avoid it in the future.

H1 SUS
arnaud.pele@LIGO.ORG - posted 12:16, Wednesday 27 February 2013 (5596)
PRM phase 3a power spectra

Set of spectra have been taken after the installation and the cabling of PRM in HAM2 chamber.

The allhltss*** plots show a comparison between LLO phase 3a (Oct 2012) LHO phase 2b (Feb 2013) and LHO Phase 3a (Feb 2013) power spectra
The 2013-02-26*** plots show a comparison between damping on and off for M1 M2 and M3 masses.

Everything looks good, nothing to worry about.

Non-image files attached to this report
H1 SUS
arnaud.pele@LIGO.ORG - posted 11:44, Wednesday 27 February 2013 (5595)
PR3 phase 3a power spectra

Set of spectra have been taken after the installation and the cabling of PR3 in HAM2 chamber.

Plots show that all osems have been plugged and are working correctly.

The allhltss*** plots show a comparison between LLO phase 3b (Sept 2012) LHO phase 2b (Feb 2013) and LHO Phase 3a (Feb 2013) power spectra
The 2013-02-26*** plots show a comparison between damping on and off for M1 M2 and M3 masses.

Looking at allhltss_2013-02-26_Phase3a_PR3_ALL_Spectra_Doff.pdf a 2.7Hz resonnance -corresponding to one of the main resonnances of M1 Yaw- shows up for M1 L/T/V/R/P (respectively pages 7/8/9/10/11). Probably, one of the earthquake stops is touching or rubbing.

 


 

Non-image files attached to this report
LHO VE
kyle.ryan@LIGO.ORG - posted 11:22, Wednesday 27 February 2013 (5594)
Valved-in MTP to X-end VE
Everything normal with the X-end MTP and QDP80 pumps -> Don't know why they shut down yesterday -> Valved in MTP to X-end and resuming pumping.
LHO General
patrick.thomas@LIGO.ORG - posted 19:34, Tuesday 26 February 2013 (5593)
plots of dust counts
Attached are plots of dust counts > .3 microns and > .5 microns in particles per cubic foot requested from 5 PM Feb. 25 to 5 PM Feb 26. Also attached are plots of the modes to show when they were running/acquiring data. The end stations are not plotted because they were rebooted and stored nan in the data.

Data was taken from h1nds0.
3060 seconds worth of data was unavailable on this server
1360.0 minutes of trend displayed

'No data output' reported for the mode and status plots.
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 19:12, Tuesday 26 February 2013 (5592)
plots of dust counts
Attached are plots of dust counts > .3 microns and > .5 microns in particles per cubic foot requested from 5 PM Feb. 24 to 5 PM Feb 25. Also attached are plots of the modes to show when they were running/acquiring data.

Data was taken from h1nds1.
1440.0 minutes of trend displayed
Non-image files attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 17:49, Tuesday 26 February 2013 (5591)
Maintenance Day. Upgrade to RCG 2.6.2

WP 3731, 3727

We upgraded H1 from RCG 2.6.1 to 2.6.2. We took the opportunity to build the H1.ipc file from scratch to clean out unused IPC channels. All models were rebuilt and restarted. In order to install new mbuf drivers we rebooted all front ends as well as restarted their models many times over the course of the day. Errors found in the restart/reboot scripts were fixed. The DAQ was restarted several times in the late afternoon when we upgraded the original h1dc0 to have two gigabit ethernet receiver cards (making it the same as the h1dc1 test system which we installed on Saturday). The new h1dc1 is powered down and acting as a backup concentrator machine.

Alex upgraded h1fw0 and h1nds0 to be the same as the h1fw1 system (upgraded Sat 23 feb). This includes new frame-cpp and framed channel status string.

New code was installed on h1seih23 to conform with the wiring drawings. An adc timing problem was seen, so that system is not running at the moment, we'll take a look tomorrow morning.

IPC problems with h1sustmsy were discovered, the SUS and SEI teams have resolved that issue.

The PSL models would not compile due to recent common parts changes, for the moment we reverted back to older versions of the common parts which are consistent with our H1 models. We'll hand this over to team-PSL to upgrade their system at  later time.

We tested "front end restarts not invalidating other front ends data" (fixed by giving each front end its own mx stream end point), and could not reproduced this error.

We tested pressing the "DAQ Reload" button on a variety of front ends and could not reproduce model crashing or front end lock outs which were seen before 2.6.2.

We discovered a left-over EPICS 40 char name limit in or 3.14.10-epics-long state notation compiler, this was extended to 60 chars.

In summary: all front ends are now running 2.6.2, the original h1dc0 data concentrator is running with the extra 10gigabit ethernet port, front ends have their own end-point for mx stream daq data transfer.

LHO General
michael.rodruck@LIGO.ORG - posted 16:48, Tuesday 26 February 2013 (5590)
Ops summary
LHO VE
john.worden@LIGO.ORG - posted 16:43, Tuesday 26 February 2013 (5589)
Hard-closed GV7

~1630 hrs. local

John W.  requested that I increase the air pressure applied to the top of GV7's piston to ~20 psi so that we could be assured that the "Soft-closed" GV7 gate was in full contact with its O-rings.  If not in full contact, IP6 might be pumping hydrogen from the X-arm which would confuse the pressure comparison between the two BTs.  -> As found,  the piston close pressure was ~5 psi -> I increased this to 20 psi -> GV7's gate cammed fully closed a few minutes later

GV7 is now "Hard-closed"

LHO General
patrick.thomas@LIGO.ORG - posted 16:22, Tuesday 26 February 2013 (5588)
restarted dust monitors and weather stations
I restarted and burtrestored the IOCs for the dust monitors and weather stations at both end stations to recover from a loss of connection.
LHO VE
kyle.ryan@LIGO.ORG - posted 16:19, Tuesday 26 February 2013 (5587)
Pumping at X-end shut down unexpectedly
The turbo pump system at X-end shut down for no obvious reason around midday(?) today -> I used this "down time" do some routine maintenance on the QDP80 backing pump (grease rotor bearings, change gear oil - 400cc Krytox - and top off heat exchanger coolant but these all looked normal) -> Restarted QDP80 and MTP -> I'll leave these running but valved out from the X-end VE for overnight 

Operators Note:  
X-end under vacuum but unpumped overnight, i.e., X-end pressure will be increasing and PT510B value may change from "green" to "yellow" if left this way indefinitely - no action is required.  

H2 SEI
hugh.radkins@LIGO.ORG - posted 16:18, Tuesday 26 February 2013 (5586)
WBSC8 HEPI/iLIGO CAS Swap Update
Got the first Corner(NE) HEPI Housing down from BSC8.  The iLIGO CAS Support Stack is part way in and will continue tomorrow.