Reports until 17:00, Thursday 16 August 2012
H1 SEI
kyle.ryan@LIGO.ORG - posted 17:00, Thursday 16 August 2012 (3874)
"Bumped" external dial indactor(s) on HAM2 support tubes
During course of R&Ring center down-facing feed-through flange and extending purge air header beneath HAM1,2.  
LHO General
gerardo.moreno@LIGO.ORG - posted 16:18, Thursday 16 August 2012 (3873)
Ops Summary

Noisy day, which permited lots of noisy activities.

H2 TCS
aidan.brooks@LIGO.ORG - posted 15:36, Thursday 16 August 2012 (3872)
Calibration of H2 ETMY HWS lever arm [10.35 +/- 0.03mm]

[Jax, Aidan, Elli]

This morning we calibrated the lever arm of the HWS. We added a beam splitter (CAL-BS) into the optical path to hit the HWS CCD with two beams (REFL and TRANS) at ~ 10mrad to each other. We removed the Hartmann plate from the sensor and recorded the resulting interference pattern on the CCD. The spatial frequency of the interference pattern allowed us to determine the exact angle between the two beams, 9.86mrad, with a precision of approximately 1:500. Next we replaced the Hartmann plate and measured the Hartmann sensor spot pattern of each beam separately by blocking first one and then the other beam. We centroided the spots and determined the mean centroid displacement, 8.507 pixels. Knowing the measured angle, the pixel size (12E-6 m) and the spot displacement, we determined that the lever arm distance (between the Hartmann plate and the CCD) is 10.35 +/- 0.03mm.

The data is attached. Also attached is an optical layout showing the additional beam splitter producing the reflected and transmitted beams.

We made certain to remove the beam splitter and check the final alignment of the HWS system was restored to nominal before closing up the ETM ALS table.

The reference lever arm that has been used before now is 10.0mm.

Images attached to this report
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 13:56, Thursday 16 August 2012 (3871)
dust monitors
Replaced the fuse for the dust monitor in the clean room over HAM 3 (LVEA location 15). Restarted the EPICS IOC.
Added a dust monitor in the clean room over HAM1 and 2 (LVEA location 9).
X1 SEI
corey.gray@LIGO.ORG - posted 11:54, Thursday 16 August 2012 (3870)
HAM #7 Serial Numbers

Collected as much serial number as possible on the nearly completed HAMISI#7 (just a few remaining tests for it).  There was one item I was not able to get, namely the a Flexure; it was oriented in a way that made its s/n NOT viewable (waiting to see if someone jotted this info when they built the system).  Below are all the other s/n's:

Stage0:  014

Stage1:  010

Optics Table:  009 

Corner1

Actuators

GS13s

L4Cs

CPS Sensor

Flexure:  -- not viewable, installed upside-down :(

Spring:  030

Support Post:  031

Corner2

Actuators

GS13s

L4Cs

CPS Sensor

Flexure:  046

Spring:  041

Support Post: 017

Corner3

Actuators

GS13s

L4Cs

CPS Sensor

Flexure: 040

Spring:  045

Support Post:  032

H1 SUS
jeffrey.kissel@LIGO.ORG - posted 07:34, Thursday 16 August 2012 - last comment - 16:22, Monday 01 October 2012(3865)
H1 SUS PR2 Phase 2B Final Answer
B. Bland, J. Garcia, J. Kissel

Attached are plots comparing the recent H1 SUS PR2 Phase 2B measurements against other HSTS in various stages (completing the data package) in order to give a final answer on Phase 2B testing.

As of this entry H1 SUS PR2 passes Phase 2b and is go for install into HAM3, with the following caveats:
(1) Late in the game, the assembly team found an IR filter is missing on an M3 (Bottom) stage AOSEM. The spectra comparisons show that there's little-to-no difference in the response of sensor, i.e. it's functional (as far as you can tell in the noisy chamber-side environment). Regardless, the assembly team are aware of the problem, and will replace that AOSEM once in chamber, as there's plenty of room to play around in there, and it's a simple fix.

(2) It's a long story (so I'll save it for a subsequent comment to this log), but we discovered the same small T to Y cross-coupling at 1.1 and 2.05 Hz on PR2 as was recently discovered on X1 SUS MC3. At the time, (we thought) X1 SUS MC3 was the only SUS that had such cross coupling, and (we knew we) still had lots of chances to debug the issue before install, so we approved his Phase 1b results and agreed to move forward. However, due to the hectic/scattered measurements and turn-on blips of getting the HAM SUS up and running at LHO, the cross coupling in H1 SUS PR2 (formerly X1 SUS PR2) has fallen under the radar up to this point. So, in light of several things:
- (As in seen in the attached TF comparisons, specifically pg 2, the M1 to M1 T to T TFs), ONLY X1 SUS MC3 and H1 SUS PR2 show this particular cross coupling, out of Nine other HSTS that have been built project wide (again further clues, a better zoom, theories, and conjectures to come).
- We will move X1 SUS MC3 chamber-side, and the install team will spend an extended amount of time identifying/debugging the problem where there's plenty of room, and less pressure. Once the problem is solved, they will retroactively make the same changes to H1 SUS PR2 in chamber, where (at least in HAM3) there's a comfortable amount of room to make adjustments.
- Again, the coupling is small, and goes away with damping -- the concern is the model, which we use extensively to predict motion estimates, may not be as accurate.
 
Ease of later documentation, the individual measurements that compose the rest of the package are aLOGged here:
Damping Loops OPEN M1 to M1 TFs: LHO aLOG 3851
Damping Loops CLOSED M1 to M1 TFs: LHO aLOG 3855
Amplitude Spectra of All Stages: LHO aLOG 3861
Non-image files attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 16:22, Monday 01 October 2012 (4339)

M3 stage UL AOSEM swapped.  See this alog:

https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=4338

H2 SUS
jeffrey.garcia@LIGO.ORG - posted 23:11, Wednesday 15 August 2012 (3868)
TMTS medm modifications

The overview medm for the TMTS suspension was modified today to correct mislabled channels.  A DC align medm part was ported over from the QUAD medm directory for use in setting DC offsets on the TMTS suspension.  All changes were committed to the cds_user_apps SVN.                                                                         

H1 General
rainer.weiss@LIGO.ORG - posted 20:55, Wednesday 15 August 2012 (3867)
Report on the hydrocarbon measurements at the y end
A report on the measurements of the hydrocarbon residual gas at the y end has been posted
on the LIGO DCC with a document number LIGO T1200395-v1. The hydrocarbon pressure,
now with all the advanced LIGO components in the chamber, raises concern. The data and the
suggestions of actions to take are discussed in the document.
LHO General
patrick.thomas@LIGO.ORG - posted 18:51, Wednesday 15 August 2012 (3866)
plots of dust counts
Attached are plots of dust counts > .5 microns in particles per cubic foot.
Non-image files attached to this report
H1 AOS
jeffrey.kissel@LIGO.ORG - posted 17:32, Wednesday 15 August 2012 (3861)
H1 SUS PR2 Phase 2B Damping ON/OFF Spectra
In order to complete the individual data set for H1 SUS PR2's phase 2B testing, I attach the amplitude spectral densities of all stages of OSEMs. Tough to determine anything from these plots:
 - there's so many dang plots,
 - one is only comparing damping ON vs OFF, so you're only looking for "do the damping loops
       - Damp the resonances
       - Add any unexpected additional noise at any stage"
but given those limited criteria, the answer is "looks fine..."

Stay tuned for comparison with other spectra and a more concrete/final answer.
Non-image files attached to this report
LHO General
michael.rodruck@LIGO.ORG - posted 16:21, Wednesday 15 August 2012 (3864)
Ops summary
H2 TCS
aidan.brooks@LIGO.ORG - posted 16:17, Wednesday 15 August 2012 (3863)
Ring heater temperature - self measurement

It turns out that the Ring Heater itself can be used to measure it's temperature. The resistivity changes with temperature. We see the voltage change over the first hour when the heater is turned on: - this is due to an increase in temperature of the ring heater wire and a subsequent change in the resistivity of the nichrome winding.

I've estimated the temperature of the ring heaters over time using a nominal value of 0.00017 K^-1 for nichrome and the measured RH voltage from last week's test. You can see the results in the attached plot.

T0 = 1029555836 for Segment 1

T0 = 1029555847 for Segment 2

Voltage signals = H2:TCS-ETMY_RING_HTR_SEG1_V_MON_OUTPUT, H2:TCS-ETMY_RING_HTR_SEG2_V_MON_OUTPUT

Current signals = H2:TCS-ETMY_RING_HTR_SEG1_I_MON_OUTPUT, H2:TCS-ETMY_RING_HTR_SEG2_I_MON_OUTPUT

Non-image files attached to this report
H1 PSL
michael.rodruck@LIGO.ORG - posted 16:10, Wednesday 15 August 2012 (3862)
PSL plots

35W beam

We had trouble locking the FSS, and left it unlocked for several days. This was tracked down to the cable going to the FAST actuator and was replaced yesterday, and it's held lock since then, so it looks fixed. This is the reason for the drop in the crystal temperature.

Images attached to this report
Non-image files attached to this report
H1 SEI
hugh.radkins@LIGO.ORG - posted 13:47, Wednesday 15 August 2012 (3860)
WHAM2 ISI Elevation Set
CoreyG HughR

We had done some large horizontal moves of the ISI per IAS (Initial Alignment) on Aug 1.  So after that we wanted to check the elevation.  It was still pretty close: 0.9mm low at worse with a range of 0.4mm level.  The vertical was tweaked to desired elevation +-0.1mm: -252.9(LIGO Global--E1000403)+12.5(Global to local--T1100187)=-240.4mm.

To Do list for SEI at HAM2: Respond to IAS with HEPI moves.  Iterate Horizontal/Vertical adjustments.  When good, attach HEPI Actuators, recheck with IAS.
Meanwhile--fine tune ISI lock/unlock balance.  Test ISI in prep for SUS payload.  Unload dummy payload when testing complete.
H2 SEI
vincent.lhuillier@LIGO.ORG - posted 13:28, Wednesday 15 August 2012 (3858)
T240 in stage 1 super sensor at BSC8 + additional information

General:
Last week, the ISI, SUS and HEPI models-screens were updated to receive the last features and to replace the EPICS connection between the SUS and SEI watchdogs by the reflective memory (BSC6). The dolphin connection (SUS-SEI) will be added on BSC8 next week. The safe snap shots were also updated.

Ramping functions:
Both isolation filters of the ISIs and HEPIs can now be ramped using a function launched from MEDM. A restart procedure is currently being written. The DCC # is E1200762.

ISI Control:
I have changed the compensation filters of the output filter bank of ISI-BSC6 and ISI-BSC8. The cut-off frequency of the compensation filters was lowered 2 weeks ago (losing 6 degrees of phase at 30Hz). By the time, the watchdogs were tripping when engaging the boost filters. The “Turn on” option of the boost filters was changed from “zero crossing” to “ramp” (10s). The current filters are the initial ones.

I have introduced the T240 in the stage 1 blend of the 2 ISIs. The isolation provided by stage 1 using the T240 in the super sensor is higher (factor 5-6 @ 2Hz) than with L4Cs in the blend. During a quiet period, several configurations were tested. I have attached some results of few measurements on ISI-BSC8:

The first plot ITMY_T240_Y_2012_08_14_aLOG.pdf shows the non calibrated ASD of the stage 1 velocity (measured by the T240) in the Y direction with the different configurations:
- Damping only
- L4C X-Y-Z blend at 250mHz; L4C RX-RY-RZ blend at 750mHz; No Isolation on stage 2
- T240 X-Y-Z blend at 250mHz; L4C RX-RY-RZ blend at 750mHz; No Isolation on stage 2
- T240 X-Y-Z blend at 100mHz; L4C RX-RY-RZ blend at 750mHz; No Isolation on stage 2

The second plot ITMY_GS13_Y_2012_08_14_aLOG.pdf shows the non calibrated ASD of the stage 2 velocity (measured by the GS13) in the Y direction with the different configuration:
- Damping only
- L4C X-Y-Z blend at 250mHz; L4C RX-RY-RZ blend at 750mHz; No Isolation on stage 2
- T240 X-Y-Z blend at 250mHz; L4C RX-RY-RZ blend at 750mHz; No Isolation on stage 2
- T240 X-Y-Z blend at 100mHz; L4C RX-RY-RZ blend at 750mHz; No Isolation on stage 2
- T240 X-Y-Z blend at 100mHz; L4C RX-RY-RZ blend at 750mHz; Isolation on stage 2 – 750mHz blend
- T240 X-Y-Z blend at 100mHz; L4C RX-RY-RZ blend at 750mHz; Isolation on stage 2 – 250mHz blend

Blend switcher for the ISI:
The blend switcher allows changing blend frequency and type (CPS-L4C blend or CPS-T240-L4C blend) on the fly. It's working well. However, the isolation filters still have to be ramped up with the CPS-'L4C in the blend since the T240s saturate in the ramping process due to the small initial DC offsets (with the reference position) of the platform.

HEPI:
The blend and isolation filters controlling the pringle modes were reintroduced. The transfer functions used for sensor correction are linked below:
- H2_HPI_ETMY_H2_HPI_ETMY_TF_STS2_To_L4C_2012_07_03_044933.fig
- H2_HPI_ETMY_H2_HPI_ETMY_TF_STS2_To_L4C_2012_07_03_044933.pdf

Non-image files attached to this report
H2 ISC
daniel.sigg@LIGO.ORG - posted 12:43, Wednesday 15 August 2012 (3857)
EY PLL Locking
(Bram, Alberto, Daniel)

This morning we were investigating the odd PLL oscillations that prevented us from increasing the servo gain. We found a very narrow resonance around 287.56kHz with a Q>100. We saw this resonance before, but it seemed to have had a much lower Q. It is unclear why this resonance has become so much more pronounced in the past few days. Our 100kHz low pass filter was designed to take care of this, but is obviously not sufficient to suppress a high Q resonance. Reducing the ugf to 6.5kHz avoids the instability, but will require that the cavity locking servo runs at a lower ugf too.

We then successfully locked the cavity. Looking at the I and Q signals it seemed that the RF phase was poorly adjusted. We first switched the delay line phase shifter to external, so we can use the medm screen to adjust the phase. Secondly, we minimized the Q signal by going from 135º (255 steps) to 85º (160 steps). We left the delay line in external mode. Meaning, it is important to restore the EPICS settings after a reboot.

While we were out there we also fixed the missing RF level readbacks from the second wavefront sensor demodulator board. They were connected to the wrong connector of the ASC demodulator concentrator.
Images attached to this report
H1 SUS
betsy.weaver@LIGO.ORG - posted 11:02, Wednesday 15 August 2012 (3855)
H1 PR2 Phase 2b Glass DAMP ON TFs
The DAMP ON PR2 transfer function measurements were taken yesterday afternoon and this morning. Data has been exported to .txt files and the DTT .xml templates saved.

DTT .xml files and exported .txt files are saved and committed to the SUS SVN locally under:
'/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PR2/SAGM1/Data/'

DTT .xml file names used:
2012-08-14_1810_H1SUSPR2_M1_WhiteNoise_L_0p1to50Hz.xml
2012-08-14_1810_H1SUSPR2_M1_WhiteNoise_T_0p1to50Hz.xml
2012-08-14_1810_H1SUSPR2_M1_WhiteNoise_V_0p1to50Hz.xml
2012-08-15_1438_H1SUSPR2_M1_WhiteNoise_R_0p1to50Hz.xml
2012-08-15_1438_H1SUSPR2_M1_WhiteNoise_P_0p1to50Hz.xml
2012-08-14_1810_H1SUSPR2_M1_WhiteNoise_Y_0p1to50Hz.xml

Exported .txt file names used:
2012-08-15_1438_H1SUSPR2_M1_WhiteNoise_L_0p1to50Hz.txt
2012-08-15_1438_H1SUSPR2_M1_WhiteNoise_T_0p1to50Hz.txt
2012-08-15_1438_H1SUSPR2_M1_WhiteNoise_V_0p1to50Hz.txt
2012-08-15_1438_H1SUSPR2_M1_WhiteNoise_R_0p1to50Hz.txt
2012-08-15_1438_H1SUSPR2_M1_WhiteNoise_P_0p1to50Hz.txt
2012-08-15_1438_H1SUSPR2_M1_WhiteNoise_Y_0p1to50Hz.txt

PDFs of plots:
'/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PR2/SAGM1/Results/'

Saved as:
2012-08-15_1438_H1SUSPR2_M1_*_TF*.pdf

Data committed.
H1 SUS
betsy.weaver@LIGO.ORG - posted 07:44, Wednesday 15 August 2012 - last comment - 08:28, Wednesday 15 August 2012(3853)
PR2 DAMP ON TFs (continued Phase 2b) running NOW

I am running these TFs - please do not touch the PR2.  It should only take me an hour, I'll alog when I am done.

Comments related to this report
betsy.weaver@LIGO.ORG - 08:28, Wednesday 15 August 2012 (3854)

I am done with the last Damp On pR2 TFs.  Damping has been left on.  Installers - I'll keep you posted with the results of the analysis today such that you can prepare the sus.  Hold tight for a few hours...

H1 SUS
jeffrey.garcia@LIGO.ORG - posted 12:24, Wednesday 01 August 2012 - last comment - 11:04, Wednesday 15 August 2012(3683)
H1 SUS PR2 SAGM1 TF comparison
The attached is the latest transfer function measurements taken on H1 SUS PR2 SAGM1 stage.  The data was taken 07-29-2012 and is plotted with the predicted model and a previous measurement from the metal build in the Staging Building.  The pdfs are committed to the SUS SVN under:
'~/sus/trunk/HSTS/Common/Data/allhstss_2012-07-29_*'

Data committed in:
'~/sus/trunk/HSTS/H1/PR2/SAGM1/Data/2012-07-29_H1SUSPR2_M1_WhiteNoise_*DoF*_0p1to50Hz.txt'

DTT templates used had the same name but with an "xml" extension.
Non-image files attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 13:51, Wednesday 01 August 2012 (3686)

Great - since these TFs do not show any indication of rubbing, and the SUS is still healthy, we can begin the metal-to-glass swap.

janeen.romie@LIGO.ORG - 11:04, Wednesday 15 August 2012 (3856)
After digging through the old file hoping to compare them against thelatest data, I found that this data set was saved wihout the "_HHMM_" tag in the date and time portion of the file name. I've svn moved and committed all associated .xmls and .txt files such that they now have a "_1838_" (the HHMM of the Longitudinal TF), and then re-ran plotHSTS_dtttfs.m, saving new plots and .mat files, so that they can be properly used in the plotallhsts_tfs.m for future reference.

So, new files are:

${SusSVN}/sus/trunk/HSTS/H1/PR2/SAGM1/

.xmls of raw data:
Data/2012-07-29_1838_H1SUSPR2_M1_WhiteNoise_L_Op1to50Hz.xml
Data/2012-07-29_1838_H1SUSPR2_M1_WhiteNoise_P_Op1to50Hz.xml
Data/2012-07-29_1838_H1SUSPR2_M1_WhiteNoise_R_Op1to50Hz.xml
Data/2012-07-29_1838_H1SUSPR2_M1_WhiteNoise_T_Op1to50Hz.xml
Data/2012-07-29_1838_H1SUSPR2_M1_WhiteNoise_V_Op1to50Hz.xml
Data/2012-07-29_1838_H1SUSPR2_M1_WhiteNoise_Y_Op1to50Hz.xml

.txts of exported data:
Data/2012-07-29_1838_H1SUSPR2_M1_WhiteNoise_L_0p1to50Hz.txt
Data/2012-07-29_1838_H1SUSPR2_M1_WhiteNoise_P_0p1to50Hz.txt
Data/2012-07-29_1838_H1SUSPR2_M1_WhiteNoise_R_0p1to50Hz.txt
Data/2012-07-29_1838_H1SUSPR2_M1_WhiteNoise_T_0p1to50Hz.txt
Data/2012-07-29_1838_H1SUSPR2_M1_WhiteNoise_V_0p1to50Hz.txt
Data/2012-07-29_1838_H1SUSPR2_M1_WhiteNoise_Y_0p1to50Hz.txt

.mat of data processed by plotHSTS_dtttfs.m:
Results/2012-07-29_1838_H1SUSPR2_M1.mat

and attached is the individual SUS's set of plots which include off-diagonal TFs.
Non-image files attached to this comment
Displaying reports 84901-84920 of 88667.Go to page Start 4242 4243 4244 4245 4246 4247 4248 4249 4250 End