Reports until 11:49, Friday 29 June 2012
H1 SEI
hugh.radkins@LIGO.ORG - posted 11:49, Friday 29 June 2012 (3310)
HAM3 ISI Elevation/Level Check--Not Bad
JimW & Hugh

The 'locked' (w/ lockers) level of the Optical Table was measured with the Optical Auto Level.  The table is level to 0.7mm p-p.  We also assessed the LIGO global elevation and the Optical Table average is 1mm below design height.  This all may sound sloppy but given that the system was leveled using the exterior of the Support Tubes, we then connected those to the new HEPI Crossbeams, and then placed 8000 lbs on them.  So I for one, am very happy that the optical table is now where it is.

Next we'll float the system on HEPI and adjust the level and elevation.
H2 PEM
david.barker@LIGO.ORG - posted 11:23, Friday 29 June 2012 (3309)
h2peml0 new cabling and model

I shuffled the new cabling for ACC, MAG and MIC on the h2tcsl0 AA chassis to fill in any gaps. I modified the h2peml0 model to add the new channels and also added a permanent IRIGB signal in channel 30 in prep for tomorrow's leap second addition to UTC testing.

 

H2:PEM-CS_ACC_BEAMTUBE_X_DQ
H2:PEM-CS_ACC_BSC8_X_DQ
H2:PEM-CS_ACC_BSC8_Y_DQ
H2:PEM-CS_ACC_OLY_X_DQ
H2:PEM-CS_ACC_OLY_Y_DQ
H2:PEM-CS_CHAN_29_OUT_DQ
H2:PEM-CS_MAG_LVEA_FLOOR_X_DQ
H2:PEM-CS_MAG_LVEA_FLOOR_Y_DQ
H2:PEM-CS_MAG_LVEA_FLOOR_Z_DQ
H2:PEM-CS_MIC_LVEA_FLOOR_DQ
H2:PEM-CS_MIC_OLY_DQ
H2:PEM-CS_SEIS_LVEA_FLOOR_X_DQ
H2:PEM-CS_SEIS_LVEA_FLOOR_Y_DQ
H2:PEM-CS_SEIS_LVEA_FLOOR_Z_DQ
H2:PEM-CS_TILT_LVEA_FLOOR_T_DQ
H2:PEM-CS_TILT_LVEA_FLOOR_X_DQ
H2:PEM-CS_TILT_LVEA_FLOOR_Y_DQ
H2:PEM-CS_TIMING_IRIGB_OUT_DQ
H2:PEM-CS_ACC_BEAMTUBE_X_DQ
H2:PEM-CS_ACC_BSC8_X_DQ
H2:PEM-CS_ACC_BSC8_Y_DQ
H2:PEM-CS_ACC_OLY_X_DQ
H2:PEM-CS_ACC_OLY_Y_DQ
H2:PEM-CS_CHAN_29_OUT_DQ
H2:PEM-CS_MAG_LVEA_FLOOR_X_DQ
H2:PEM-CS_MAG_LVEA_FLOOR_Y_DQ
H2:PEM-CS_MAG_LVEA_FLOOR_Z_DQ
H2:PEM-CS_MIC_LVEA_FLOOR_DQ
H2:PEM-CS_MIC_OLY_DQ
H2:PEM-CS_SEIS_LVEA_FLOOR_X_DQ
H2:PEM-CS_SEIS_LVEA_FLOOR_Y_DQ
H2:PEM-CS_SEIS_LVEA_FLOOR_Z_DQ
H2:PEM-CS_TILT_LVEA_FLOOR_T_DQ
H2:PEM-CS_TILT_LVEA_FLOOR_X_DQ
H2:PEM-CS_TILT_LVEA_FLOOR_Y_DQ
H2:PEM-CS_TIMING_IRIGB_OUT_DQH2:PEM-CS_ACC_BEAMTUBE_X_DQ
H2:PEM-CS_ACC_BSC8_X_DQ
H2:PEM-CS_ACC_BSC8_Y_DQ
H2:PEM-CS_ACC_OLY_X_DQ
H2:PEM-CS_ACC_OLY_Y_DQ
H2:PEM-CS_CHAN_29_OUT_DQ
H2:PEM-CS_MAG_LVEA_FLOOR_X_DQ
H2:PEM-CS_MAG_LVEA_FLOOR_Y_DQ
H2:PEM-CS_MAG_LVEA_FLOOR_Z_DQ
H2:PEM-CS_MIC_LVEA_FLOOR_DQ
H2:PEM-CS_MIC_OLY_DQ
H2:PEM-CS_TIMING_IRIGB_OUT_DQ
 
all are 2048Hz except the two MIC and the IRIGB channels which are at 16384Hz
H1 PSL
michael.rodruck@LIGO.ORG - posted 11:17, Friday 29 June 2012 (3308)
Optimizing PMC mode matching

Rick S, Michael R

After the low power transition and some first order alignment correction we had about 10.7W transmitted through the PMC and 2W at reflection. However, some peaks in the modescan indicated mode matching issues, so we decided to move the mode matching lenses L2 and L3 to improve this. We couldn't use the alignment ramp on the PMC screen so we instead ramped the PZT on the NPRO and adjusted the crystal temperature using the slow actuator to move between modes.

Our procedure was to first optimize the position of L2, then move L1 and L2 in iterative steps until the mode matching peak is minimized.

To optimize L2:

  1. Scan NPRO PZT
  2. Look at PMC reflection PD and ISS PDA on a scope
  3. Adjust position of L2 by 1cm on rail
  4. Move slow actuator to alignment peak, adjust pointing to minimize
  5. Move slow actuator to mode matching peak (what faintly looked like a 02/20 on the camera) and measure voltage
  6. Repeat steps 3-5 until the mode matching voltage is minimized

Once L2 position was optimized we then started adjusting L1 as well:

  1. Adjust position of L1 by 1cm on rail
  2. Move slow actuator to alignment peak, adjust pointing to minimize
  3. Move slow actuator to mode matching peak and measure voltage
  4. If the voltage decreased, then repeat steps 1-3 for L2. Otherwise adjust L1 in the opposite direction
  5. Continue to iterate between moving L1 and L2 until the mode matching peak is minimized

We now have 11.6W in transmission and 0.8W in reflection. Visibility is 90% (going off of PD voltage readings). We did not fully minimize the peak so there is still more power to be gained. However, another mode appeared to grow as we minimized the 02/20 mode, which looks on a viewing card like a 02 hermite horizontal.

The attached spreadsheet shows positions of the lenses and the corresponding 02/20 mode voltages. Positions are measured at the North end (towards HAM1) of the lens mounting block.

FSS settings were checked again. UGF is at 400kHz with 55 degrees of phase margin. Common gain set to 23 dB.

Non-image files attached to this report
H1 INS
jodi.fauver@LIGO.ORG - posted 10:47, Friday 29 June 2012 (3307)
Xend Prep
Below is the checklist we are using to guide work at Xend. So far, we've only agreed on sequence of events through all grouting.

1. Retrofit chamber cleanroom-done
2. Position BSC9-done
3. Set BSC9-should be done today
4. Position/set BSC 9 HEPI piers
5. Build 1 Type C cleanroom
6. Cleanings
7. Stage for spool install
8. Install/set spool pieces and legs
9. Grout BSC9, HEPI piers, spool legs
Logbook Admin General
jonathan.hanks@LIGO.ORG - posted 08:03, Friday 29 June 2012 (3305)
test of posting
The LHO alog disk had filled up with backups.  This caused problems creating entries.  This entry is a test that everything is working.
H1 AOS
thomas.vo@LIGO.ORG - posted 07:46, Friday 29 June 2012 (3304)
HWS Imaging Measurements
Elli, Thomas

In our attempt to decouple the motion of ETMY in pitch and yaw to the Hartmann sensor beam motion, we have been actuating on ETMY with a frequency of .35 HZ and an amplitude of 50 counts on the M0 stage and running a transfer function. Then changing the lenses on the table to alter the imaging path length till we get a nominal length so that the transfer function is at a minimum. The plot is attached below showing the actuation in yaw, we might need to do more measurements in yaw and then proceed on to pitch.  We're looking for a minimum coherence of at least .9
Images attached to this report
H2 ISC
keita.kawabe@LIGO.ORG - posted 18:55, Thursday 28 June 2012 - last comment - 19:42, Thursday 28 June 2012(3300)
continuous lock (Jax, Elli, Keita with a help from SUS people)

It's been locked for more than 30 minutes, and the beam spot is much brighter than yesterday! Another victory.

I'll attach my shoddy cell phone video later so you can see the beam motion on the ETMY. It's still moving, but it's not as bad as yesterday thanks to SUS people's effort (and of course that was essential to this long lock).


Detalis:

SUS people supplied us an updated analysis with new boost filters for each of big resonances. I played around with the gain of PIT and LONG gain a bit. When I increased the LONG gain by another factor of 10 (on top of a factor of 10 that I put in earlier), it immediately started oscillating and tripped the watchdog, but a factor of 2 (i.e. total of 20) was doing good, so I ended up with this:

H2:SUS-ETMY_M0_DAMP_L_GAIN: -20 (originally -1)

H2:SUS-ETMY_M0_DAMP_P_GAIN: -0.033 (originally -0.1)

I didn't touch Y gain even though it is with a new boost filter.

After this, I was able to see that the beam motion was reduced by maybe a factor of 1.5 or 2 by a highly scientific method of eyeballing the beam on the cage using my eyes. The DC level of the reflected beam was still fluctuating by about 20%, though (as opposed to 50 to 60% from yesterday) due to the beam motion.

Jax, Elli and I looked at the table and confirmed that the DC level of the Hartman path, which is just picked off of the main beam path upstream of the Faraday, does not fluctuate. 

 

After touching alignment, I felt as if the demod signal amplitude is much smaller than yesterday even though I was confident that the alignment was already reasonable. Yesterday we were getting something like 3-4Vpp, while today I got only 300-400mVpp.

I ignored that (modulation depth might have changed for some stupid reason), optimized the demod phase by using toggle switches on the delay line front panel, and plugged the CM board output to the VCO tune input. It didn't lock at first as the overall gain was too small (because the error signal is smaller), so I increaded the gain in Beckhoff world and voila!

Right now I can lock to 00 mode and 01 mode, and 01 mode is also sort of bright. Apparently we can refine alignment further, and it would be easier tomorrow as we can lock to 00 mode for however long we want.

Comments related to this report
keita.kawabe@LIGO.ORG - 19:01, Thursday 28 June 2012 (3301)

It would be helpful to have a bigger aperture Faraday. That would improve the crappy beam qualith that is injected into the chamber while reducing the DC power fluctuation on the PDH diode. We say "one stone, two birds" in Japan.

keita.kawabe@LIGO.ORG - 19:07, Thursday 28 June 2012 (3302)

Before/After plot of the new ETMY SUS configuration.

The new one (current traces) is definitely better.

The reference traces are the same as the reference in my previous entry https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=3292 claiming that mere change in the gain didn't help. However, according to Matt, their comparison shows that mere gain change actually helped, so my references might have been from some really quiet time.

Images attached to this comment
keita.kawabe@LIGO.ORG - 19:42, Thursday 28 June 2012 (3303)

Video.

Once in a while (e.g. towards the end from 24 sec) the power drops and comes back in sync with the beam motion.

Non-image files attached to this comment
LHO General
patrick.thomas@LIGO.ORG - posted 18:01, Thursday 28 June 2012 (3299)
plots of dust counts
Attached are plots of dust counts > .5 microns in particles per cubic foot.
Non-image files attached to this report
H1 SEI
hugh.radkins@LIGO.ORG - posted 16:40, Thursday 28 June 2012 (3298)
HAM3 Post ISI Install Work
JimW, Alex & Hugh---We forklifted and hefted in 800+lbs onto the HAM3 ISI Optical Table, enough to get it floating.  The Shipping Braces were removed and the Lockers were then locked.  We connected the CPS cabling to the feedthrus in preparation of floating and balancing.  The one missing bolt connecting the ISI to the East Support Tube, Corey noted during ISI Installation, was not successfully installed.  It remains loose and need to be removed and replaced.
LHO General
corey.gray@LIGO.ORG - posted 16:38, Thursday 28 June 2012 (3297)
OPS Shift Summary

HAM3 ISI had payload installed, and the ISI was floated.

HEPI acatuators were craned off of BSC7

Various tests/work done related to the OAT & SUS

H2 SEI
hugh.radkins@LIGO.ORG - posted 16:31, Thursday 28 June 2012 (3296)
BSC7 North Side HEPI Actuators Removed re WP 3302
EricA & HughR---Keita gave us a window to use the crane from 1130 to 1330, that was nice of him wasn't it!  At least it made for a shorter afternoon.
Anyway, no issues, removed the horizontal and vertical actuators on the two north piers of BSC7.  The main crane was out of position during that time and moving occasionally.  Just the SW corner left and then BSC4.  3/8ths done.
H1 SUS
betsy.weaver@LIGO.ORG - posted 14:11, Thursday 28 June 2012 (3295)
PR2-04 Lefft Primary Prism glued

Afterfussing with the setup all afternoon yesterday and another few hours today, I finally glued the first primary prism to the HAM3 PR2. It looks to be off in the d-value disance, but the fixture/microscope setup is such that you cannot check any numbers once the prism is glued and being cured in the fixture.  So, I'll have to wait until tomorrow when the glue is mostly cured to remove the fixture and remeasure everything again.

H1 IOO
chris.mueller@LIGO.ORG - posted 13:24, Thursday 28 June 2012 (3294)
Input Optics in the PSL
[Michael R., Guido M., Rick S., Chris M.]

The input optics on the PSL table have been moved from H2 to H1.  The main beam path is aligned up to the bottom periscope mirror which has been left in the cabinet for safety.  All of the auxillary beams are aligned as well, but most of the electronics are yet to be installed (rfpd, dcpd, piezo mirror).  The alignment is as shown in D0902114.  

The periscope spacers have also been moved from H2 to H1 but are actually off in height by 1.25 inches.  New spacers are being machined and should be ready to be installed within the next month.  
We looked at the mode matching into the interferometer using beam scans with the WinCam.  The overap (in power) between the fitted beam and the mode cleaner mode is 98.7%.  The data wasn't robust enough (Rayleigh range is too large) to fit an M^2 value though.  The attached plot Mode_Matching_to_IMC.pdf shows the measured data with fits as well as the ideal beam.  

The H2 EOM has been moved to the H1 table which means that the sideband frequencies will all need to be modified.  Volker Q. will work on this when he is here in the middle of July. Hopefully the final RF system will be in place by then.  

For now we have checked out the AM/PM ratio for the 8.68 MHz sideband.  As usual with RFAM the measurement was not completely conclusive.  We initially measured a value of 4.9e-4, but were able to bring it down to 1.5e-4 by adjusting the alignment on the PD (without any significant change in the DC value).  We also put an iris in front of the PD and by adjusting the aperature size were able to bring it down to 4.9e-5 again without any significant change in the DC value.  Our hypothesis is that it is caused by scattered light possibly from the blocked s polarized beam from the EOM.

Methods of measurement and definitions of modulation indices can be found in an attachment to https://alog.ligo-la.caltech.edu/aLOG/index.php?callRep=2901.  The attached spreadsheet H1_PSL_Data.ods contains the data described above.  
Non-image files attached to this report
H2 SUS
jeffrey.kissel@LIGO.ORG - posted 12:58, Thursday 28 June 2012 (3293)
H2 SUS ETMY Open Loop Gain Measurements (With Legacy Filters and Gains)
J. Kissel, M. Evans

---------
These are the results and analysis from the Open Loop Gain TF measurements of H2 SUS ETMY mentioned below. For details of the measurement and setup, please check out the associated comments to that entry. 
---------

In order to check / confirm that the damping loops were "working as expected," I took Open Loop Gain TFs of the degrees of freedom of interest to the excess motion recently found in H2 SUS I/ETMY; Longitudinal (L), Pitch (P), and Yaw (Y). Attached are the results.

Each collection of plots shows the Open Loop Gain TF (in red), and a reference Plant TF (in black). 
The black traces are what we typically loosely call simply "TFs," which are taken from with the excitation point from the out-of-loop TEST bank. These are in OSEM repsonse [ct]s / COIL drive [ct]s, but because all frequency response in the analog signal chain is compensated, the calibration is merely a collection of scale factors; an even scale factor of 60 -- so we can consider it in [m/N] or [rad/N.m] which is indeed the "plant," P, of the damping control loop. 
The new red traces are taken by exciting through the DAMP filter bank, which means the measurement includes the damping filters and gains, -K, and is hence the Plant times the Filters, P*-K == G, or the Open Loop Gain. Here, because we're sensing and actuating from the same point in the loop (i.e. the input to the damp filters), the transfer function is dimensionless, and no calibration is necessary. Also, because the loop is defined with minus sign explicitly outside of the damping filters, the stability criteria is for Upper Unity Gain crossings to stay away from -180, and Lower Unity Gain crossings to stay away from +180. 

These plots confirm what was mentioned below, that with the gains as is [er was by now], the

- L is basically undamped for both SUS, especially its low frequency modes (where the dominant RMS motion lies), because the Open Loop Gain is below 1,
- P is totally squashed (over-damped), especially the higher frequency modes; not necessarily obvious from these plots -- because it's unclear from the open loop gain how much suppression one would get, it merely shows that you have lost of gain over all resonances -- but it certainly obvious from the closed loop TF plots in the previous log.
- Y could maybe use a little more juice at low frequency, but otherwise looks OK


It's from the combination of these plots and the previous plots our "quick fix" recommendation came: it looks like there was plenty of phase-margin head room to increase the gain of the L loop by 10, and decreasing the P gain by a factor of 3 looked like we could still get some gain at the resonances, without squashing them entirely.

Of course, while writing this log, I found that Keita had remeasured the performance using these new "quick fix" gains, and found that the motion has increased. So, I will tuck my tail between my legs and head back to the drawing board with my thinking cap on. l'*sigh*.
Non-image files attached to this report
H2 SUS
jeffrey.kissel@LIGO.ORG - posted 10:11, Thursday 28 June 2012 - last comment - 11:31, Thursday 28 June 2012(3290)
H2 SUS I/ETMY TOP Stage TF Data Mining in the interest of Excess Motion
J. Kissel, M. Evans

Forgive me while I catch you up to where we are.

Here's some data collected over the course of these SUS's lifetimes thus far. An a priori thanks goes to J. Garcia for taking most of this data!

I collect it all in one place, with the data shown in the mindset of the discussion of why there's so much excess motion in Pitch (during ambient times). I'll show more plots later that show that it's actually Longitudinal that's going nuts, but ... we'll get there.

Remember that both ETMY and ITMY have the same exact filters with the same exact gains.


For now: check out the attached. We will find out that (1) is more useful than (2).
------------
(1) I show a collection of data that is representative of the current situtation, comparing damping loops ON vs. OFF (see allquads_120628_H2SUS_DampingComp_ALLM0_ZOOMED_TFs.pdf). From this plot, we immediately notice the following:

- L is basically undamped for both SUS, especially its low frequency modes (where the dominant RMS motion lies)
- P is totally squashed (over-damped), especially the higher frequency modes
- T, R, V, and Y could maybe use a little more juice, but otherwise look OK -- but even in these DOFs, the lowest frequency modes are poorly damped

These particular filters were designed for the LASTI QUAD, with the gains copied and pasted without really looking at anything more than the ring down time, and (they haven't [changed/been tuned] since Brett's QUAD at LASTI  4 years ago, and therefore what gains were in place in March are still in place now). 

(2) Then, just because cross-coupling came up in conversation, I show the "detail" plots for each of the damped data sets. In particular, take a look at the cross-coupling plots (pgs 7-19) to get a direct measurement of the cross coupling between various degrees of freedom. Note that I've added the Y to L / L to Y plot (pg 13), which is not normally shown because it's not a physically expected cross-coupling. Why? Because we were at one point confused as to whether the excess motion was in Pitch or Yaw. I think, because of the spectra shown yesterday, now we're reasonably convinced that the excess motion during quiescent times is Pitch.

It's admittedly quite difficult to discern and information from these plots, because they're in all sorts of different units... but you can eye-ball it, and see that what cross-coupling does exist is reasonably well below the "diagonal" terms of the transfer function. On the to-do list: make these plots more readable by [converting them into/using] the conversion from rad to m (either modeled or measured).

------------

I'll post a separate log with what I think is going on, with better data to prove it, but I'll say here just in case people are impatient:

- L is totally undamped, both in L and P. The tons of excess motion seen in P at 0.43 and 1.0 Hz are L modes, that, because of fundamental cross coupling are showing up a lot in P. As of yet, we only have a good measure of the test mass P, since we don't have any cavities to measure the L. 
- Because we're overdamping P so much, when those who saw only pitch increased the P gain, the loop went unstable, so we couldn't solve the problem directly.
- From the looks of the open loop gain plots (which will be shown in a separate log, where I'll spell out the problem and solution in greater detail) my proposed "quick fix" solution:
    Decrease the P gain by 3.
    Increase the L gain by 10.
See if that works / helps.
    

OK. I wanna show the open loop plots, so lemme get this up and out, so I can start working on that aLOG.
Non-image files attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 11:31, Thursday 28 June 2012 (3292)

Increased H2:SUS-ETMY_M0_DAMP_L_GAIN by 10 (originally -1, now -10).

Decreased P gain by 3 (originaly -0.1, now -0.033).

Attached is the plot of L1 (not M0, for no apparent reason other than I felt like it) OSEM signals. Current traces (red/blue) are after the change, references are before.

In general, after the change it looks worse, though this is not an entirely fair comparison as the current data was taken whey people (Elli, Jax, Keita, Gerardo and MikeR) were around and doing stuff but that might not be the case for the references.

Images attached to this comment
H1 SEI
corey.gray@LIGO.ORG - posted 18:57, Wednesday 27 June 2012 - last comment - 10:28, Thursday 28 June 2012(3269)
HAM3 Dial Indicators & In-Vac Cabling (a first start)

(corey, jim)

Dial Indicator Install (this work was on Tues)

Dial Indicators used to monitor the HAM3 ISI/HEPI system are roughly in place.  This hardware should not be touched/bumped as it will be used to monitor and ultimately help position the HAM3 ISI. 

Cabling (this work started Wed)

In-Vac Cabling for HAM3ISI is mapped out according to D1002874.  Since Septum work finished up this afternoon, I started running Corner-1 cables to their feed through.  I was able to get all cables to the feedthrough (but opting NOT to screw down to feed-thru), EXCEPT for the H1 Actuator (it's 70" long cable was a foot or so too short!).  At any rate, I only ran cables for Corner-1.  I went to the other side of the chamber and separated Corner-3 cables from Corner-2 (since they're going to opposite sides of the Chamber).  Corner-3 looks like it will be the tough one to work on (due to feed-thru in middle of Chamber).

I labeled the dirty side of feedthroughs.

Images attached to this report
Comments related to this report
hugo.paris@LIGO.ORG - 10:28, Thursday 28 June 2012 (3291)

H1 Actuator cable will be replaced with a 135" (shortest available now)