Displaying reports 85821-85840 of 88488.Go to page Start 4288 4289 4290 4291 4292 4293 4294 4295 4296 End
Reports until 19:11, Wednesday 02 May 2012
H2 SUS
jeffrey.garcia@LIGO.ORG - posted 19:11, Wednesday 02 May 2012 (2750)
H2 SUS ITMY R0 Trans. DoF Transfer Functions
Travis S., Jeff G.

H2 ITMY R0 transfer function measurements were taken this morning for the Transverse DoF after mechanical adjustments on the R0 top mass. The flag in the R0 "SD" OSEM was observed to be grazing the OSEM housing.  The OSEM housing was re-positioned laterally to center the flag.  After this adjustment,  the attached measurement was taken with a white noise excitation on the R0 Trans. test excitation channel.  The blue trace is the measurement this morning, while the black is a reference trace from Monday.  This DoF appears to be free again with the resonances clearly visible.
Non-image files attached to this report
X1 SEI
james.batch@LIGO.ORG - posted 16:55, Wednesday 02 May 2012 - last comment - 17:17, Wednesday 02 May 2012(2748)
Manually removed old /frames files
The SEI test stand daqd process was failing because the /frames disk was full.  To correct, removed oldest full, minute trend, and second trend files.  This should be done automatically, need to investigate.  Also corrected port number of NDSSERVER environment variable for seiteststand2.
Comments related to this report
hugo.paris@LIGO.ORG - 17:17, Wednesday 02 May 2012 (2749)

I ran a quick check. This fix corrected our issues. Thank you.

H2 TCS
aidan.brooks@LIGO.ORG - posted 16:31, Wednesday 02 May 2012 (2747)
H2 HWS EY install - tidied up electronics on ALS table
Yesterday, Thomas and I tidied up the HWS electronics on the ALS table that is now at the end station. The two power cables connecting to the Hartmann sensor have been attached and those cables, plus the fiber-optic and temperature sensor cable that go to the Hartmann sensor, have been tied to a post and routed up the cable tray to the HWS breakout box (see attached photo).

The feedthrough panel was replaced with a new version where the 37-pin feedthrough is horizontal and doesn't interfere with the Bosch/Unistrut framing of the enclosure.

We installed the on-table temperature sensor by the second lens in the HWS imaging system (see attached photos). We moved the Hartmann sensor 2" closer to the PBS to get the fiber-optic cable out of the beam path behind it. I still need to lengthen the optical system by 2" to compensate for this and keep the image plane of the ETM on the Hartmann sensor surface.
Images attached to this report
X1 SEI
corey.gray@LIGO.ORG - posted 15:51, Wednesday 02 May 2012 (2746)
HAM ISI Assembly Work

HAMISI #5 Mechanical Checks & Measurements

(corey, eric, hugo, jim)

Dial Indicators were re-installed.  We conducted many of the range of motion checks for Hugo.  Jim re-balanced the table as well.  Not able to get S/Ns for Horizontal Actuators, but since we don't have "real" GS13s in this assembly, we'll get the S/Ns when we pull out these "tester" gs13s.

HAMISI #6 Stiffener Complete

(corey, eric)

We assembled the Stiffener.  It is all torqued down, and we checked for any gaps with a 0.002" shim (we looked good).  Tomorrow we will install the Support Posts and can move the Stage-0 assembly on to the Test Stand.

LHO General
patrick.thomas@LIGO.ORG - posted 15:33, Wednesday 02 May 2012 (2745)
dust monitor
I replaced the fuse for the dust monitor in the clean room over BSC8 (LVEA location 15).
H2 SEI
hugh.radkins@LIGO.ORG - posted 12:41, Wednesday 02 May 2012 - last comment - 08:29, Thursday 03 May 2012(2744)
BSC6 ETMY Work & Status
GregG & HughR
Greg went in chamber and added the screws to the ISC Cables that had none.  These were reconnected and are now secure to the FeedThru.  These were the ISC Transmon 532nm & Beam Diverter cables.
Also, Greg connected the one still dangling cable to F3-3C2 (D1003085), presumably this is the TCS-Ring Heater cable.

Next we took some level shots on the Optical Table and saw +-0.2mm level.  We made some slight HEPI tweaks and using the dial indicators as a guide to what we did, we now have the level to +-0.1mm.  So this should be good.

We'll make the Actuator Connections next.
Comments related to this report
keita.kawabe@LIGO.ORG - 08:29, Thursday 03 May 2012 (2754)

Note my earlier alog entry.

https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=2586

Logbook Admin Feature Requests
jeffrey.kissel@LIGO.ORG - posted 06:17, Wednesday 02 May 2012 (2743)
L-mail Feature Requests
Often, in our haste to write aLOGs, we may put up errant / incomplete information. After a re-read later, we may correct typos, add extra files / information, etc. Y'know, edit it. However, when these logs are edited, they send out L-mail as though they were new. For those of us that forget about the "preview" feature, my request is as follows:
(1) If an entry is edited vs. newly created, the L-mail message should reflect that. Instead of "A new report has been made...," perhaps something like "A report has been edited..."
(2) We should have the ability to suppress L-mail notification with the understanding that, like the DCC, this should be discouraged, and reserved only for minor changes (e.g. typographical). I've seen this ability in other logbooks, like The Seismic Group Notebook.


On a separate request, but still involving L-mail (and maybe the "link" feature in general): it is often very useful to see not only the specific log entry that has been linked from L-mail, but the context around it. Is there anyway for an entry's link to take you to the full page of surrounding entries, in addition to just the linked entry? I've found that sometimes, when I get around to reading my L-mail, that the entry of interest has fallen off the "front page" of the log, so when I hit "home" to see the other log entries around it, I have to re-find the entry, through several more clicks.
H2 SUS
jeffrey.garcia@LIGO.ORG - posted 23:08, Tuesday 01 May 2012 (2738)
FMY whitenoise TFs
Today, FMY M1 WhiteNoise transfer function measurements were taken on the FMY M1 top mass for each DoF. There have been concerns of rubbing from measurements last	taken in mid-March.  Comparisons with previous measurements will follow.  
Non-image files attached to this report
H1 PSL
oliver.puncken@LIGO.ORG - posted 22:41, Tuesday 01 May 2012 (2742)
Resassembly of the PSL (Part 1)
PSL installation team

April, 27th

- Craned PSL oscillator, amplifier, gantry crane and others over from the H2 LAE to H1 LAE (see photo).
- Beckhoff up and running.
- Cabeling at the PSL racks next to the enclosure is ongoing.

April, 30th

- replaced all four water filters (those underneath the optical table and the ones at the chiller returnes). All of them are 10 µm filters now.
- removed lifting frame from the oscillator box and mounted the oscillator, the mopa and the DBB to the optical table.
- Put the new cabinets into the H1 ante-room and moved stuff (spare components / PSL components) over from the H2 ante room 

May, 1st

- moved/cleaned one of the cabinets from H2 ante room, because we needed one more for the H1 ante room. It contains the spare HiPoPMC et al.
- MOPA turned on and aligned (output 33.9 W)
- all spare components and components from the "old" optical table are now inside the H1 LAE (this includes the high power PMC / ISS box)
- started to put optis on the laser table
- characterized fiber bundles for the high power oscillator: two fiber bundles (#2,#3) are already reassembled to the oscillator. Fiber bundle #1 has been cleaned twice.
- removed the 4f lenses and the laser crystals from the oscillator as preparation for the pre-alignment procedure.
Images attached to this report
X1 SEI
hugo.paris@LIGO.ORG - posted 17:22, Tuesday 01 May 2012 (2741)
HAM-ISI Assembly Validation Procedure (Phase I) - Updated

HAM-ISI Assembly Validation Procedure (Phase I) was Updated. The new version is available in the DCC

A brief desciption of the modifications applied will be given at the next SEI Testing and Commissioning Meeting.

H2 ISC
keita.kawabe@LIGO.ORG - posted 17:17, Tuesday 01 May 2012 (2740)
EY ALS laser controller was connected to the laser kill switch circuit

We're not transitioning to laser hazard yet.

But pretty soon (tomorrow hopefully) we'll start transitioning back and forth (daytime=safe, after IAS and others are done = hazard).

H2 AOS
jason.oberling@LIGO.ORG - posted 17:13, Tuesday 01 May 2012 (2739)
BSC06 ETMy Pitch Alignment and XY Position Check
ETMy Pitch Alignment
 
IAS: J. Oberling
SUS: T. Sadecki
 
We aligned the ETMy pitch this morning.  We started at 300 µrad down and after a series of adjustments left the pitch at 658 µrad down.  Our target for mechanical adjustment is 639 ± 160 µrad, so this is well within our spec.
 
 
ISI XY Position Check
 
IAS: J. Oberling
 
This afternoon I checked the lateral (X) and axial (Y) position of the ISI table.  Since we are using the PLX retroreflector (those of you that have been in chamber have probably noticed the large structure sitting in the spool piece; this is the PLX) and setting the total station up behind BSC06 we can not directly measure the position of the ETMy.  What we decided to to instead was to measure the position of the ISI and use the position numbers from the test stand alignment to then calculate the ETMy position.
 
The ISI position is measured in two steps: Y position and X position.  We had set a monument on the North side of BSC06.  This monument represents the desired Y position of the ISI, corrected for the +4mm of the ETMy axial positioning measured on the test stand.  In other words, for the ETMy to be at its correct axial position, the Y centerline of the ISI (line is perpendicular to the optical axis of the Y arm cavity) should line up with this monument.  To measure this, we set a total station on the monument, bucked in on the North offset line and turned it 90 degrees.  We then used a bracket designed to hang a plumb bob from the ISI centerline, since the centerline falls in between screw holes on the ISI table; the bracket has two holes for attaching to the ISI table and smaller hole in between the two larger for hanging the plumb bob.  We can sight the wire used to hang the plumb bob with the total station and measure the angle; it is then a matter of simple trig to calculate the position error of the centerline. 
 
Unfortunately, the bracket was designed with 2" between the screw holes instead of 1 (the ISI table is on a 1" hole pattern).  This makes it impossible to use the bracket as-is for its intended purpose.  To get around this I used a bar supplied by Travis to clamp the bracket in position.  This worked, but since the bracket is being aligned visually an approximate ±1mm error is introduced into the position of the plumb bob hole (the centerlines of the ISI are scribed, so there is a visual reference for placement of the bracket, but they are wide, ~2mm).  I was then able to sight the wire and measure the angle to it.  As the plumb bob was swinging slightly I had to sight the edges of the swing and find the midpoint.  There is some error here in sighting the wire as it swings.  I was able to see angular changes of ~5 arcseconds, which leads to a position error of approx. ±0.08mm.  This puts the error estimate for this measurement at approx. ±1.08mm.  With that in mind here are the numbers for the ISI position, reported as distance from its nominal position:

Correcting these numbers with the ETMy test stand positions gives the current ETMy position errors (error spec is ±1.0mm for X, ±3.0mm for Y):

With the estimated error, this puts the ETMy lateral position either within spec or wildly out of spec.  The axial position is in spec regardless.

H2 SEI
hugh.radkins@LIGO.ORG - posted 16:47, Tuesday 01 May 2012 (2737)
BSC6-ETMY ISI is Uncovered
Vincent was ready to use the opportunity of BSC6 availability so I've uncovered the ISI.  For several days now, the ISI has been covered allowing work down below in the cleanroom, with the doors covers in place, with just a frock, cap, & mask.  Now that the ISI is uncovered, all entrance to the BSC6 cleanroom requires full bunny garb.
LHO General
jonathan.berliner@LIGO.ORG - posted 16:43, Tuesday 01 May 2012 (2736)
Tuesday Aft Ops Log
I relieved Corey at ~12:00 today, who was relieving someone else during the morning.
- Fire alarm maintenance was here in the afternoon.
- Apollo made a delivery for Hugh at ~13:55.
- EY: IAS, SEI, ALS, TMS, usual work. Phone communication still not working from the Control Room to EY (unclear if signal block is electronic or human in nature).
- BSC8: SLC, SUS working on finishing up BSC8 ITM, FM installation. We should work on keeping a camera pointed at BSC8 because the Control Room receives many inquiries regarding the status of work at BSC8.
- LVEA dust monitors not working for much of the day.
- AEI group continues working at PSL.
- Ops: Please give feedback to Cheryl.
- OSB doors locked at 16:05.
X1 SEI
corey.gray@LIGO.ORG - posted 15:39, Tuesday 01 May 2012 (2735)
ISI Assembly Status

HAMISI#5 Work (Corey, Jim)

HAMISI#6 Work

H2 CDS
james.batch@LIGO.ORG - posted 13:40, Tuesday 01 May 2012 (2734)
Install new version of epics software for Ubuntu linux workstations
Moved /ligo/apps/linux-x86_64/epics to point to epics-3.14.12.2_long to fix bugs.  StripTool now works on Linux workstations.  This version has been installed for Darwin for several months with no problems.
LHO General
corey.gray@LIGO.ORG - posted 12:10, Tuesday 01 May 2012 (2733)
Mid-Day Shift Summary

 BSC8 (ITMy)

Zeroing offsets of HEPI this morning(Hugh)

BSC6 (ETMy)

BSC3

In Chamber Cleaning begins

Miscellaneous

Visitors

H2 ISC
daniel.hoak@LIGO.ORG - posted 17:44, Monday 30 April 2012 (2731)
ALS table to End-Y
After growing up in the optics-table nursery next to HAM-6, the ALS table has struck out on its own into the wider world.  It found a nice rent-controlled place about 2.5 miles to the south that advertises an unobstructed view of ITMY.  It's settling in; the cable guy is scheduled to arrive tomorrow sometime between 8am and 4pm.

Before the move, Alberto and I wrapped all the external fixtures in Ameristat, plugged holes with clean-room tape, and then wrapped the entire table enclosure and the legs in plastic wrap to keep the dust off.  The Apollo crew did a masterful job craning the table out of the laser area (table weight: 2250 lbs) and then moved it to the flatbed trailer with a forklift.  Despite winds gusts that had to be ~45mph, the trip to the end was smooth.  We stripped the plastic wrap off in the first highbay area, gave everything a thorough wipe-down with alcohol wipes, and pushed the table into its new home.  Thanks to TVo and Tomoki for the help.

The HEPA fan for the table is plugged in and running.  We lowered the screws on the table legs; we'll probably have to fine-tune the position once we start aligning beams, but for now there's enough friction that you won't move the table if you push on it.

Pictures attached; there's a time-lapse video of our trip down the arm here: http://www.youtube.com/watch?v=zZ4hqGtzz40
Images attached to this report
H2 AOS
keita.kawabe@LIGO.ORG - posted 12:27, Thursday 26 April 2012 - last comment - 10:03, Tuesday 01 May 2012(2705)
TMS and HAM6 inspection (Frank, Betsy, Calum, Keita)

We inspected several things. More pictures were taken than shown here, which are to be posted to resource space by Calum.

1. Washers that were stuck

There are four stainless washers used for TMS temporary restraint that were stuck to the aluminum bracket (see  picture). I tried to lift them all gently, and they wouldn't move at all. Might be possible to ply it off using some tool, but we agreed it's not worth the risk of flipping and flying them to break wires.

2. A cable that is not connected

There was one cable that is not connected yet, and we identified it as the ring heater cable connecting CB-3 and the vacuum feed through (F3-3C2). This is going to be taken care of later.

One thing I noticed is that the floor order for this bracket is reversed. CB-3 first floor (closest to the  ISC table) should be one of the ETMY SUS cables, and the second floor should be the ring heater according to D1101478, but in reality it was the opposite (see the second picture, the white-ish cable is for the ring heater).

It's easy to tell the difference because of the color, but I think it's still a good practice to install things as specified for future workers.

3. One of the TMS cables was brushing the HWS mirror

The cable sagged, apparently. We fixed this (see the third and the fource picture).

Images attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 10:16, Monday 30 April 2012 (2727)

Boo. BSC6, not HAM6.

betsy.weaver@LIGO.ORG - 10:03, Tuesday 01 May 2012 (2732)
Note - When I assembled the cable connectors on those brackets, I fed back all of the changes I made to the layout guys (SYS).  I am waiting for an update to the cable layout drawing based on these.  The order of the "flooring" of the connectors in the bracket make more sense the way they are now, hence redlines to the drawing.
Displaying reports 85821-85840 of 88488.Go to page Start 4288 4289 4290 4291 4292 4293 4294 4295 4296 End