Displaying reports 82221-82240 of 86143.Go to page Start 4108 4109 4110 4111 4112 4113 4114 4115 4116 End
Reports until 10:45, Thursday 30 August 2012
H1 PSL
michael.rodruck@LIGO.ORG - posted 10:45, Thursday 30 August 2012 (4038)
PSL plots

35W beam

Images attached to this report
Non-image files attached to this report
H1 SUS
jeffrey.bartlett@LIGO.ORG - posted 10:28, Thursday 30 August 2012 (4037)
H1-PRM First TFs
Andres and I ran the first set of transfer functions on H1-PRM yesterday. The results are posted in the attached files. There is a problem with P, R, and V. We are checking the suspension for EQ stops rubbing, OSEM alignment, and Flag positioning and will rerun the transfer functions after taking corrective action. 

The first set of transfer functions were taken in the afternoon with no one in the Triples Lab (where the suspension is located) and only light assembly work (no forklifts, moving BSC plates, etc) underway on the ground floor.  As a test, I repeated taking the transfer functions last night after everyone had left the staging building for the night. There was no difference between the TFs taken during the day and at night. Conclusion: As long as the Triples Lab is empty and there is limited activity in the rest of the staging building, we should be able to test suspensions during normal working hours.      
Non-image files attached to this report
H1 SEI
corey.gray@LIGO.ORG - posted 10:22, Thursday 30 August 2012 (4036)
6.8 Greenland Earthquake Trips SEI Watchdogs

This morning at 14:11utc (7:11am Pacific time) a couple of earthquakes reached us.  This tripped both BSC8 & BSC6 ISI & HEPI.  The initial quake was a 6.8 (13:43utc) & the aftershock was 5.2 (13:51utc).  Attached is a trace of one of the SEI Watchdogs (i.e. BSC8 ISI Stage1).

Non-image files attached to this report
H2 General
jaclyn.sanders@LIGO.ORG - posted 09:42, Thursday 30 August 2012 (4033)
Cavity scan methodology

During a cavity scan, a second modulation is applied to the laser frequency. The response of a Fabry-Perot cavity to laser frequency modulation contains information about the cavity parameters, including cavity length, free spectral range, modal spacing, and the radius of curvature of the cavity optics. The goal of cavity scans is to measure cavity characteristics and characterize their time evolution in response to heating of the optics.

While the 532 nm ALS laser is locked to the arm cavity, laser frequency modulations are injected into the Innolight Prometheus frequency-doubled laser through the laser frequency servo (Common Mode A) with an SR785 signal analyzer. These frequency modulations are transmitted into the 1064 nm beam used for PSL phase locking and the 532 nm beam used for arm cavity locking. The PSL phase locking beam does not interact with the arm cavity, and the signal from the RF photodiode is used as a proxy for the signal injected into the arm cavity. The arm cavity reflection photodiode gives the output signal, which the SR785 divides by the input signal to produce a transfer function.

Automation of SR785 measurements is necessary to perform and store transfer functions in quick succession over a period of hours. A Prologix GPIB-Ethernet controller is used for remote control and retrieval of data from the SR785. Scripts for performing transfer functions and retrieving data using the GPIB-Ethernet interface were created for use at the 40m interferometer, and were used for cavity scan transfer functions here. The Python script exttt{TFSR785.py} performs a single transfer function.

A bash script, exttt{autoTF}, was used to repeatedly call this Python script. This script was originally set to perform one scan from 30kHz to 80kHz, alternate smaller scans around the first-order modes (from 46-47 kHz and from 65.75-66.75 kHz) three times, then repeat until 12 hours elapses or the script is terminated. During the scan, it was found that the first-order peaks moved further than anticipated, so the script was altered to scan from 45-46 kHz and 66.75-67.75 kHz. In future scans, the smaller scans will be run from 45-47 kHz and 65.75-67.75 kHz for the duration. For all scans, the amplitude of the excitation was 10 mV, and 10 averages were used.

The ALS laser output power is 100 mW, and the SR785 excitation output current is 100 mA. Therefore, the modulation depth for these cavity scans is 0.1, or 1% of power in the modulation sidebands.

The attachment cavity_characterization.pdf contains a more thorough explanation of the motivation behind cavity scans, and some preliminary results. The attachment cavityshift.pdf plots a cold cavity scan and a cavity scan after 2.5 hours of heating on the same axes, showing the shift in modal spacing with ITM heating.

Non-image files attached to this report
H1 AOS
andres.ramirez@LIGO.ORG - posted 08:41, Thursday 30 August 2012 (4030)
Start of H1-HSTS-PRM Phase 1b Testing. OSEMs Data.
H1-HSTS-PRM is ready for Phase 1b testing. OSEMs have been centered and tested. Check the attached file for data on Open Light Values, Offsets, Gains, etc.
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 19:39, Wednesday 29 August 2012 (4028)
plots of dust counts
Attached are plots of dust counts > .5 microns in particles per cubic foot.
Non-image files attached to this report
LHO VE
kyle.ryan@LIGO.ORG - posted 16:27, Wednesday 29 August 2012 (4027)
(2) 16.5" feedthrough assemblies removed from BSC1
Kyle, Gerardo (initial)

The two leaking 16.5" feedthrough assebmlies were removed from BSC1.  A custom bracket was fabricated and utilized which allowed the assemblies to be removed with the crane (as a whole unit).    

NOTE:  Ports are covered in UHV foil but BSC1 is not within a cleanroom and is reliant on properly adjusted purge air - please don't adjust the Vertex Volume's purge air.
H2 SUS
james.batch@LIGO.ORG - posted 12:02, Wednesday 29 August 2012 (4026)
h2susb78 IOC problems
Found h2susb78 locked up as of 21:02:43 PDT Aug. 28.  Restarted, models ran about 3 minutes and communication between IOC and computer went away (one-stop card/cable issue).  The IOC one-stop card was replaced with a new revision C2 card yesterday, so suspecting an early failure, the IOC one-stop card was replaced with another one.  With this second new one-stop card, one of the main PCIe buses was not visible to the computer, and the duotone timing was off by 35uS.  

Gave up, and installed an old non-updated one-stop card back in the IOC.  System came up normally, but will have to run without problems for about 3 days before confidence begins to be restored.
X1 SUS
james.batch@LIGO.ORG - posted 09:20, Wednesday 29 August 2012 (4024)
Restarted test stands in staging building
Restarted test stands after timing system work.  Restarted IOP models, but no user models.  Applies to tripleteststand, bscteststand2, and seiteststand2.
H1 AOS
giacomo.ciani@LIGO.ORG - posted 08:57, Wednesday 29 August 2012 - last comment - 12:46, Thursday 30 August 2012(4023)
HAUX: small progress towards testing
[Alex, Deepak, Cheryl, Giacomo]

Yesterday we finished alignment of the remaining 2 HAUX. All 4 are aligned and hooked up.
The optical lever setup is in place, but no pitch balancing has been done yet.

Electronics is up and running, the model has been restored to a clean working state after reboot, and BURT saved:
- all OSEMs offsets and gains set
- Damping filter set to (what I think are) reasonable values (no much though on this as of now: they just work to damp the optic) and set to the off state
- Hardware LP filter set to ON (but see later)
- Coils TEST enable flag set to 1.
- Master switches are off

Note that although the hardware for binary IO is on, apparently there is no state change when we change the flags in the software. It is not clear if status is not changed, or if is changed but not reported. This will need to be investigated this morning.
Comments related to this report
filiberto.clara@LIGO.ORG - 12:46, Thursday 30 August 2012 (4031)
Added missing (Binary) cables in rack SUS-C3, from IO chassis (FE IO Chassis 2 HAM-A Controls) to Binary Input and Output Chassis. This only solved part of the issue, since the Enable and Disable bits were not switching. Opened up HAM A Coil Drivers and removed jumpers for Disable / Enable. With the jumpers in place, the state would not change regardless of input. No jumpers should be installed in P3 and P4. 

All four HAM-A Coil Drivers had the jumpers removed. 
S1201163
S1201160
S1201158
S1201161
LHO General
patrick.thomas@LIGO.ORG - posted 19:34, Tuesday 28 August 2012 (4022)
plots of dust counts
Attached are plots of dust counts > .5 microns in particles per cubic foot.
Non-image files attached to this report
H2 SEI
vincent.lhuillier@LIGO.ORG - posted 18:30, Tuesday 28 August 2012 - last comment - 14:27, Tuesday 04 September 2012(4021)
HEPI BSC6 lost its nominal position after the pump was shut down

Throughout the day, the CDS group performed multiple updates (cf Dave & Vern ALOG for details). When the computers were handed back to the users, I encountered some difficulties to restore HEPI BSC6. First, I was surprised by the large offsets on the position sensors (>10K counts ~ 15mils). Then, I realized that the pump was turned off.  But after turning the pump back on, the HEPI did not come back to its nominal position. Some tests are currently being performed to understand what’s wrong with the HEPI at the end station.

Comments related to this report
vincent.lhuillier@LIGO.ORG - 14:27, Tuesday 04 September 2012 (4073)

I have attached the IPS readouts measured during the last 10 days. We clearly see that the HEPI position changed after the pump was shut down.

Images attached to this comment
H2 ISC
alberto.stochino@LIGO.ORG - posted 18:20, Tuesday 28 August 2012 (4020)
ALS RefCav laser temperature scanned to look for more stable state of FSS

[Keita, Alberto]

Today we tried to look for a different temperature of the reference cavity laser in the attempt of making the FSS more stable. Unfortunately we had no success.

We locked the cavity with the laser set at 41, 44, 48, 52, 38, 35 degree C but the cavity kept glitching at each state.

LHO General
vernon.sandberg@LIGO.ORG - posted 17:50, Tuesday 28 August 2012 (4018)
PCIe

As described in Work Permit #3425, we replaced the "One Stop" PCIe Fiber Link cards in the "aLIGO I/O Expansion Chassis" connected to the H1 and H2 front-end computers.  This was to correct for a manufacturer's incompatibility with fiber optic cable sets.  The following I/O Chassis had their cards exchanged:

Location    computer    Chassis s/n
EY            h2susauxb6      S1103366
                h2susb6              S1001132
                h2tcsey                S1102673
                h2pemey             S1001138
                h2seib6               S1102608

LVEA      h2tcsIO                 S1102672
                h2susb478         S1001136
                h2susb78           S1001137
                h2susauxb478   S1103368
                h2seib8               S1001135

H1Elect    h1susaux34       S1104995
                h1sush34              S1103886
                h1h1susauxh2    S1103622
                h1sush2a             S1103890
                h1sush2b             S1103885
                h1psl0                   S1200685

H2 CDS
david.barker@LIGO.ORG - posted 17:42, Tuesday 28 August 2012 - last comment - 12:40, Friday 31 August 2012(4019)
H2 maintenance day

About 50% of the H2 front ends were upgraded to RCG 2.5.1 last week, this week I cleanly rebuilt and restarted all H2 frontends against 2.5.1 in conjuction with the timing change.

All of H2's timing signals were moved from the old h2 timing master to the new h1 timing master. The old h2 timing master is being decommissioned.

errors in the burt restore of the safe.snap files were seen on h2peml0, h2tcsitmy and h2pemey (my problem, I'll fix these).

Problems with a large ADC input on h2hpietmy is being tracked to a HEPI pump issue at EY.

The 24MHz RF amplifier at EY is showing a timing problem on the fanout, and its fpga led is blinking red sometimes.

Comments related to this report
daniel.sigg@LIGO.ORG - 12:40, Friday 31 August 2012 (4056)
Fixed timing synchronization of the EY RF source by power cycling the unit.
H1 CDS
david.barker@LIGO.ORG - posted 17:36, Tuesday 28 August 2012 (4017)
h1 maintenance day

All H1 front ends were rebuilt against RCG tag2.5.1 which provides an IPC Dolphin fix. Front ends were restarted in conjuction with the timing upgrade work. The following models obtained an ini file change in the upgrade

h1hpiham2, h1hpiham3, h1susmc2, h1suspr2, h1sussr2.

The H1 PSL had a complete code upgrade, making it identical to the L1 PSL code. Generic template models for ISS, FSS, PMC and DBB were applied. I also rearranged bus selector order to fix crossing connectors on the top level models. All PSL ini files showed a change. Some issue with creation and use of burt snapshot files was found and is being worked.

H2 DAQ was restarted to resync the ini file changes mentioned above.

We attempted to reproduce the slow epics problem by speeding up the backup of h1boot, but were unable to see the problem. When it appears again we have a suggested front end epics sequencer fix to try.

The H1 DMT broadcaster machine was installed by Alex. We are working some networking issues before testing this system.

some burt restore errors on the safe.snap files were seen on h1pslfss (mentioned above) and h1susim.

H1 General
filiberto.clara@LIGO.ORG - posted 16:48, Tuesday 28 August 2012 (4016)
Timing System
H2 Timing system was taken offline and moved to H1 timing system. Used main GPS antenna (used by H2) for H1 and placed a lighting suppressor before connecting to H1 master fanout chassis. When the move was done, had issues with the old H2 not locking. Richard was able to troubleshoot it by swapping the fiber ends (A and B) at the transceiver (chassis side). 
LHO General
gerardo.moreno@LIGO.ORG - posted 16:27, Tuesday 28 August 2012 (4015)
Ops Summary

Lots of reboots, and many other activities.

Other work:

H2 General
gregory.mendell@LIGO.ORG - posted 16:25, Tuesday 28 August 2012 (4014)
H2 One Arm Locked Segments
Below is information I sent to Det. Char. and DASWG last week.

Generation of H2 OAT Locked Segments is now running as a cron job on ldas-pcdev1 at LHO. It runs once per day.

The segments exist from Jul 19 2012 07:59:44 PDT. (Note that LDAS has been archiving all raw H2 data since Jul 06 2012 19:00:00 UTC.)

The segments are updated via cron one per day such that segments up to ~8 am Pacific time of the current day should appear by ~10:30 am of the same day.

The segments are going into the https://segdb2.ligo.caltech.edu database, and are called

 H2:DCH-ONE_ARM_TEST_LOCKED:1

To retrieve the segments from the database, from the LSC clusters run for example, 

$ export S6_SEGMENT_SERVER=https://segdb2.ligo.caltech.edu

$ ligolw_segment_query --database --query-segments --include-segments
H2:DCH-ONE_ARM_TEST_LOCKED:1 --gps-start-time 1029674400 --gps-end-time
1029682800 | ligolw_print -t segment:table -c start_time -c end_time -d " "

Thi example returns,

1029674400 1029678900
1029679800 1029680340
1029680400 1029681180
1029681300 1029681360
1029681420 1029681480
1029682740 1029682800

The segments are also output in ASCII, and available in segwizard format here,

http://ldas.ligo-wa.caltech.edu/ldas_outgoing/FindLockedSegs/H2OneArmSegs/segWizFiles/

and in plain startTime endTime format here,

http://ldas.ligo-wa.caltech.edu/ldas_outgoing/FindLockedSegs/H2OneArmSegs/segFiles/

For experts:

The segments are generated by running, for example,

$ find_locked_segments.py -i H2 -t H2_M --min-lock-duration=1 -c h2_onearm_locked.ini --seginsert-inifile h2_onearm_seginsert.ini --lasttimes-file h2_onearm_lasttimes.txt
-bash-4.1$ cat h2_onearm_locked.ini 

where h2_onearm_locked.ini contains this one line,

 ALS-Y_REFL_B_PWR_OUT16.mean 4300 10000

which means, the criteria for lock is that H2:ALS-Y_REFL_B_PWR_OUT16.mean is between 4300 and 10000.

The script, find_locked_segments.py, is in Det Char CVS here:

CVS/Root = :pserver:anonymous@gravity.phys.uwm.edu:/usr/local/cvs/ligovirgo

CVS/Repository = detchar/code/psl

H1 SEI
hugo.paris@LIGO.ORG - posted 18:11, Wednesday 22 August 2012 - last comment - 10:23, Wednesday 29 August 2012(3948)
HAM2-ISI - Testing progress

Electronics were troubleshooted.

SEI and SUS models were arranged to allow un-tripping HAM2-ISI Payload Watchdogs.

HAM2 model was re-compiled, installed and re-started after that. It is now running.

Matrices were filled

Input and output filters are loaded

The latest version (Version_2) of the unit-specific control scripts were copied from LASTI. They were made ready for use on HAM2. 

Spectra were taken on the ISI tilted. It is the worse configuration for GS13s and they all appear to be working fine (see attached plot).

Transfer function measurements are running overnight.

Images attached to this report
Comments related to this report
hugo.paris@LIGO.ORG - 16:45, Thursday 23 August 2012 (3965)

The transfer functions measured last night had features that are typical to mis-connected sensors/actuators. Deeper analysis allowed narrowing it down the the GS13s. 

We made a program to check for "cross-coupling transfer functions" (e.g. drive on H1, response on H2). It revealed that:

H1-GS13 was read on the channel of H3-GS13 
H2-GS13 was read on the channel of H1-GS13
H3-GS13 was read on the channel of H2-GS13
V1-GS13 was read on the channel of V3-GS13 
V2-GS13 was read on the channel of V1-GS13
V3-GS13 was read on the channel of V2-GS13

We checked our model and did not find a cause for such behaviour there. We moved on the the electronics rack and spotted the issue: GS13 In-field cables were connected to the wrong inputs on HAM2 sensor interfaces.

We ran a quick TF measurement between 500mHz and 5Hz. It confirmed that the sensors were now all correctly connected. This quick measurement is also in good accordance with what we measured on HAM-ISIs in the past which is encourraging.

TF measurement are running overnight on HAM2. They will be over by 7am. 

 

Note: A blinking notification was recently added to HAM-ISI overview MEDM screens (see attachement). It turns the green "measurement" button to blinking yellow when a TF is running. HAM2 overview screen can be seen on the Video6 monitor of the Control Room. 

Images attached to this comment
hugo.paris@LIGO.ORG - 10:23, Wednesday 29 August 2012 (4025)

Hugh and I added screwdriver tips under the top payload mass of HAM2-ISI last week, before the chamber was closed. They helped prevent this big mass of ~600lbs from causing unwanted resonances. Befoire/After comparison plots are attached.

We compared the latest transfer functions with the ones taken on LLO HAM2-ISI during the same phase of testing (Intitial In-Chamber Testing). Plots are attached. Accordance is good. We are confident that the unwanted resonance seen at 96Hz comes from the top mass. We plan on ajusting its boundary conditions with the optical table once the doors of HAM2 chamber are open again. 

Non-image files attached to this comment
Displaying reports 82221-82240 of 86143.Go to page Start 4108 4109 4110 4111 4112 4113 4114 4115 4116 End